Development and evaluation of a candidate reference measurement procedure for the determination of testosterone in human serum using isotope dilution liquid chromatography/tandem mass spectrometry

被引:53
|
作者
Tai, Susan S. -C. [1 ]
Xu, Bei
Welch, Michael J.
Phinney, Karen W.
机构
[1] NIST, Div Analyt Chem, Gaithersburg, MD 20899 USA
[2] Natl Inst Metrol, Beijing 100013, Peoples R China
关键词
testosterone; reference measurement procedure; electrospray ionization; isotope dilution; liquid chromatography/tandem mass spectrometry LC/MS/MS; solid-phase extraction; liquid-liquid extraction;
D O I
10.1007/s00216-007-1355-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A candidate reference measurement procedure for total testosterone in human serum involving isotope dilution (ID) coupled with liquid chromatography/tandem mass spectrometry (LC/MS/MS) has been developed and critically evaluated. The endogenous testosterone and its internal standard (testosterone-d(3)) were extracted from the serum matrix using a combination of solid-phase extraction and liquid-liquid extraction prior to reversed-phase LC/MS/MS. Accuracy of the measurements was evaluated by a recovery study using testosterone-spiked serum. The recovery of the added testosterone ranged from 100.0 to 100.3%. This method was applied to the determination of testosterone in frozen serum samples from three individual donors (one female and two males) with the testosterone concentrations ranging from 0.3 to 8.5 ng g(-1). Repeatability with within-set coefficients of variation (CVs) from 0.1 to 1.0% and intermediate precision with between-set CVs from 0.1 to 0.5% for both female and male serum materials were demonstrated. Excellent linearity was obtained for all linear regression lines. The detection limit at a signal-to-noise ratio of approximately 3 was 2 pg of testosterone in serum. Structural analogs as well as testosterone metabolites were tested and found to not interfere with the measurement of testosterone. This well-characterized LC/MS/MS method for serum testosterone, which demonstrates good accuracy and precision, and low susceptibility to interferences, qualifies as a reference measurement procedure that can be used to provide an accuracy base to which routine methods for testosterone can be compared and that will serve as a standard of higher order for measurement traceability.
引用
收藏
页码:1087 / 1094
页数:8
相关论文
共 50 条
  • [31] Detection of SERUM testosterone by liquid chromatography-isotope dilution tandem mass spectrometry
    Chen, Y.
    Yazdanpanah, M.
    Hoffman, Barry
    Diamandis, E. P.
    Wong, P. Y.
    CLINICAL BIOCHEMISTRY, 2008, 41 (14-15) : 1266 - 1266
  • [32] Evaluation of a bracketing calibration-based isotope dilution liquid chromatography-tandem mass spectrometry candidate reference measurement procedure for 17α-hydroxyprogesterone in human plasma
    Zhang, Qiaoxuan
    Zhang, Lu
    Lin, Haibiao
    Cai, Zhiliang
    Yan, Jun
    Wang, Qiqin
    Han, Liqiao
    Wang, Jianbing
    Ke, Peifeng
    Zhuang, Junhua
    Huang, Xianzhang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (27) : 7095 - 7104
  • [33] Development of isotope dilution-liquid chromatography/tandem mass spectrometry as a candidate reference method for the determination of acrylamide in potato chips
    Park, Sunyoung
    Kim, Byungjoo
    So, Hun-Young
    Kim, Yeong-Joon
    Kim, Jeongkwon
    Bulletin of the Korean Chemical Society, 2007, 28 (05) : 737 - 744
  • [34] Development of isotope dilution-liquid chromatography/tandem mass spectrometry as a candidate reference method for the determination of acrylamide in potato chips
    Park, Sunyoung
    Kim, Byungjoo
    So, Hun-Young
    Kim, Yeong-Joon
    Kim, Jeongkwon
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2007, 28 (05): : 737 - 744
  • [35] Development of isotope dilution–liquid chromatography/tandem mass spectrometry as a candidate reference method for the accurate determination of patulin in apple products
    Mohamed A. Gab-Allah
    Kihwan Choi
    Byungjoo Kim
    Analytical and Bioanalytical Chemistry, 2022, 414 : 1867 - 1879
  • [36] Development of a Candidate Reference Measurement Procedure for the Analysis of Cortisol in Human Serum Samples by Isotope Dilution-Gas Chromatography-Mass Spectrometry
    Migaku Kawaguchi
    Akiko Takatsu
    Analytical Sciences, 2009, 25 : 989 - 992
  • [37] Development of a Candidate Reference Measurement Procedure for the Analysis of Cortisol in Human Serum Samples by Isotope Dilution-Gas Chromatography-Mass Spectrometry
    Kawaguchi, Migaku
    Takatsu, Akiko
    ANALYTICAL SCIENCES, 2009, 25 (08) : 989 - 992
  • [38] Determination of serum cortisol using isotope dilution-liquid chromatography-mass spectrometry as a candidate reference method
    Jung, PG
    Kim, B
    Park, SR
    So, HY
    Shi, LH
    Kim, Y
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 380 (5-6) : 782 - 788
  • [39] Direct measurement of serum free testosterone by ultralfiltration and liquid chromatography-isotope dilution tandem mass spectrometry
    Chen, Y.
    Yazdanpanah, M.
    Wang, Y.
    Hoffman, B.
    Diamandis, E.
    Wong, P.
    CLINICAL CHEMISTRY, 2009, 55 (06) : A178 - A178
  • [40] Measurement of estradiol, estrone, and testosterone in postmenopausal human serum by isotope dilution liquid chromatography tandem mass spectrometry without derivatization
    Wooding, Kerry M.
    Hankin, Joseph A.
    Johnson, Chris A.
    Chosich, Justin D.
    Baek, Sung W.
    Bradford, Andrew P.
    Murphy, Robert C.
    Santoro, Nanette
    STEROIDS, 2015, 96 : 89 - 94