Development and evaluation of a candidate reference measurement procedure for the determination of testosterone in human serum using isotope dilution liquid chromatography/tandem mass spectrometry

被引:53
|
作者
Tai, Susan S. -C. [1 ]
Xu, Bei
Welch, Michael J.
Phinney, Karen W.
机构
[1] NIST, Div Analyt Chem, Gaithersburg, MD 20899 USA
[2] Natl Inst Metrol, Beijing 100013, Peoples R China
关键词
testosterone; reference measurement procedure; electrospray ionization; isotope dilution; liquid chromatography/tandem mass spectrometry LC/MS/MS; solid-phase extraction; liquid-liquid extraction;
D O I
10.1007/s00216-007-1355-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A candidate reference measurement procedure for total testosterone in human serum involving isotope dilution (ID) coupled with liquid chromatography/tandem mass spectrometry (LC/MS/MS) has been developed and critically evaluated. The endogenous testosterone and its internal standard (testosterone-d(3)) were extracted from the serum matrix using a combination of solid-phase extraction and liquid-liquid extraction prior to reversed-phase LC/MS/MS. Accuracy of the measurements was evaluated by a recovery study using testosterone-spiked serum. The recovery of the added testosterone ranged from 100.0 to 100.3%. This method was applied to the determination of testosterone in frozen serum samples from three individual donors (one female and two males) with the testosterone concentrations ranging from 0.3 to 8.5 ng g(-1). Repeatability with within-set coefficients of variation (CVs) from 0.1 to 1.0% and intermediate precision with between-set CVs from 0.1 to 0.5% for both female and male serum materials were demonstrated. Excellent linearity was obtained for all linear regression lines. The detection limit at a signal-to-noise ratio of approximately 3 was 2 pg of testosterone in serum. Structural analogs as well as testosterone metabolites were tested and found to not interfere with the measurement of testosterone. This well-characterized LC/MS/MS method for serum testosterone, which demonstrates good accuracy and precision, and low susceptibility to interferences, qualifies as a reference measurement procedure that can be used to provide an accuracy base to which routine methods for testosterone can be compared and that will serve as a standard of higher order for measurement traceability.
引用
收藏
页码:1087 / 1094
页数:8
相关论文
共 50 条
  • [21] Evaluation of a candidate reference measurement procedure for serum free testosterone based on ultrafiltration and isotope dilution-gas chromatography-mass spectrometry
    Thienpont, LM
    Van Uytfanghe, K
    Stöckl, D
    Kaufman, JM
    Fiers, T
    Ross, HA
    CLINICAL CHEMISTRY, 2004, 50 (06) : A93 - A93
  • [22] An isotope dilution-liquid chromatography-tandem mass spectrometry-based candidate reference measurement procedure for the quantification of cortisol in human serum and plasma
    Ott, Myriam
    Singh, Neeraj
    Bauland, Friederike
    Koeppl, Daniel
    Kandler, Kerstin
    Gaudl, Alexander
    Geistanger, Andrea
    Ceglarek, Uta
    Rauh, Manfred
    Geletneky, Christian
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2025,
  • [23] Determination of phenylalanine in human serum by isotope dilution liquid chromatography/tandem mass spectrometry
    Lee, Hwashim
    Park, Sangryoul
    Lee, Gaeho
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (12) : 1913 - 1917
  • [24] Evaluation of an Isotope Dilution HPLC Tandem Mass Spectrometry Candidate Reference Measurement Procedure for Total 17-β Estradiol in Human Serum
    Botelho, Julianne Cook
    Ribera, Ashley
    Cooper, Hans C.
    Vesper, Hubert W.
    ANALYTICAL CHEMISTRY, 2016, 88 (22) : 11123 - 11129
  • [25] Development of isotope dilution-liquid chromatography/tandem mass spectrometry as a candidate reference method for the determination of folic acid
    Jung, Minyoung
    Kim, Byungjoo
    Boo, Doo Wan
    So, Hun-Young
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2007, 28 (05): : 745 - 750
  • [26] Evaluation of a bracketing calibration-based isotope dilution liquid chromatography–tandem mass spectrometry candidate reference measurement procedure for 17α-hydroxyprogesterone in human plasma
    Qiaoxuan Zhang
    Lu Zhang
    Haibiao Lin
    Zhiliang Cai
    Jun Yan
    Qiqin Wang
    Liqiao Han
    Jianbing Wang
    Peifeng Ke
    Junhua Zhuang
    Xianzhang Huang
    Analytical and Bioanalytical Chemistry, 2019, 411 : 7095 - 7104
  • [27] Development and evaluation of a reference measurement procedure for the determination of total 3,3′,5-trilodothyronine in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry
    Tai, SSC
    Bunk, DM
    White, EV
    Welch, MJ
    ANALYTICAL CHEMISTRY, 2004, 76 (17) : 5092 - 5096
  • [28] Development and validation of a reference measurement procedure for certification of phenytoin, phenobarbital, lamotrigine, and topiramate in human serum using isotope-dilution liquid chromatography/tandem mass spectrometry
    Tai, Susan S. -C.
    Yeh, Chia-Yi
    Phinney, Karen W.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (06) : 1915 - 1922
  • [29] Development and validation of a reference measurement procedure for certification of phenytoin, phenobarbital, lamotrigine, and topiramate in human serum using isotope-dilution liquid chromatography/tandem mass spectrometry
    Susan S.-C. Tai
    Chia-Yi Yeh
    Karen W. Phinney
    Analytical and Bioanalytical Chemistry, 2011, 401 : 1915 - 1922
  • [30] Evaluation and clinical application of a bracketing calibration-based isotope dilution liquid chromatography-tandem mass spectrometry candidate reference measurement procedure for serum theophylline
    Du, Yuanyuan
    Yan, Qiaofang
    Zhan, Min
    Zhang, Qiaoxuan
    Huang, Di
    Zhang, Pengwei
    Yan, Jun
    Wang, Jianbing
    Huang, Xianzhang
    Han, Liqiao
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (22) : 4897 - 4906