Development and evaluation of a candidate reference measurement procedure for the determination of testosterone in human serum using isotope dilution liquid chromatography/tandem mass spectrometry

被引:53
|
作者
Tai, Susan S. -C. [1 ]
Xu, Bei
Welch, Michael J.
Phinney, Karen W.
机构
[1] NIST, Div Analyt Chem, Gaithersburg, MD 20899 USA
[2] Natl Inst Metrol, Beijing 100013, Peoples R China
关键词
testosterone; reference measurement procedure; electrospray ionization; isotope dilution; liquid chromatography/tandem mass spectrometry LC/MS/MS; solid-phase extraction; liquid-liquid extraction;
D O I
10.1007/s00216-007-1355-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A candidate reference measurement procedure for total testosterone in human serum involving isotope dilution (ID) coupled with liquid chromatography/tandem mass spectrometry (LC/MS/MS) has been developed and critically evaluated. The endogenous testosterone and its internal standard (testosterone-d(3)) were extracted from the serum matrix using a combination of solid-phase extraction and liquid-liquid extraction prior to reversed-phase LC/MS/MS. Accuracy of the measurements was evaluated by a recovery study using testosterone-spiked serum. The recovery of the added testosterone ranged from 100.0 to 100.3%. This method was applied to the determination of testosterone in frozen serum samples from three individual donors (one female and two males) with the testosterone concentrations ranging from 0.3 to 8.5 ng g(-1). Repeatability with within-set coefficients of variation (CVs) from 0.1 to 1.0% and intermediate precision with between-set CVs from 0.1 to 0.5% for both female and male serum materials were demonstrated. Excellent linearity was obtained for all linear regression lines. The detection limit at a signal-to-noise ratio of approximately 3 was 2 pg of testosterone in serum. Structural analogs as well as testosterone metabolites were tested and found to not interfere with the measurement of testosterone. This well-characterized LC/MS/MS method for serum testosterone, which demonstrates good accuracy and precision, and low susceptibility to interferences, qualifies as a reference measurement procedure that can be used to provide an accuracy base to which routine methods for testosterone can be compared and that will serve as a standard of higher order for measurement traceability.
引用
收藏
页码:1087 / 1094
页数:8
相关论文
共 50 条
  • [41] Candidate Reference Measurement Procedure for the Determination of (24R),25-Dihydroxyvitamin D3 in Human Serum Using Isotope-Dilution Liquid Chromatography-Tandem Mass Spectrometry
    Tai, Susan S-C.
    Nelson, Michael A.
    ANALYTICAL CHEMISTRY, 2015, 87 (15) : 7964 - 7970
  • [42] Quantitative determination of human serum testosterone via isotope dilution ultra-performance liquid chromatography tandem mass spectrometry
    Sun, Guang
    Xue, Jinmei
    Li, Liuxu
    Li, Xue
    Cui, Yaqiong
    Qiao, Bin
    Wei, Dianjun
    Li, Huiqiang
    MOLECULAR MEDICINE REPORTS, 2020, 22 (02) : 1576 - 1582
  • [43] Measurement of serum progesterone by isotope dilution liquid chromatography tandem mass spectrometry: a candidate reference method and its application to evaluating immunoassays
    Yufei Wang
    Tianjiao Zhang
    Haijian Zhao
    Weiyan Zhou
    Jie Zeng
    Jiangtao Zhang
    Chuanbao Zhang
    Wenxiang Chen
    Analytical and Bioanalytical Chemistry, 2019, 411 : 2363 - 2371
  • [44] A simple and reliable measurement procedure for determination of glycocholic acid in human serum by isotope-dilution liquid chromatography-tandem mass spectrometry
    Wang, Ahui
    Xu, Yuzhu
    Ou, Yangfen
    Han, Liqiao
    Zhang, Qiaoxuan
    Zhan, Min
    Liu, Hongcan
    Ke, Peifeng
    Yan, Jun
    Huang, Xianzhang
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2021, 464
  • [45] Measurement of serum progesterone by isotope dilution liquid chromatography tandem mass spectrometry: a candidate reference method and its application to evaluating immunoassays
    Wang, Yufei
    Zhang, Tianjiao
    Zhao, Haijian
    Zhou, Weiyan
    Zeng, Jie
    Zhang, Jiangtao
    Zhang, Chuanbao
    Chen, Wenxiang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (11) : 2363 - 2371
  • [46] Measurement of urea in human serum by isotope dilution mass spectrometry: A reference procedure
    Kessler, A
    Siekmann, L
    CLINICAL CHEMISTRY, 1999, 45 (09) : 1523 - 1529
  • [47] Determination of serum creatinine by liquid chromatography isotope dilution tandem mass spectrometry (LC-IDMS/MS): A candidate reference method
    Rasoul, Alikhani-Koupaei
    Mehrdad, Yazdanpanah
    Eleftherios, Diamandis
    Barry, Hoffman
    Khosrow, Adeli
    Jeffrey, Tong
    CLINICAL BIOCHEMISTRY, 2008, 41 (14-15) : 1273 - 1273
  • [48] Development of isotope dilution-liquid chromatography/tandem mass spectrometry as a candidate reference method for the accurate determination of patulin in apple products
    Gab-Allah, Mohamed A.
    Choi, Kihwan
    Kim, Byungjoo
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (05) : 1867 - 1879
  • [49] Measurement of serum uric acid by isotope dilution liquid chromatography tandem mass spectrometry: Modification of a candidate reference measurement method and its clinical application
    Yan, Jun
    Lin, Haibiao
    Xu, Yuzhu
    Yu, Lintao
    Chen, Song
    Zhang, Qiaoxuan
    Han, Liqiao
    Ou, Yangfen
    Zhan, Min
    Wang, Jianbing
    Ke, Peifeng
    Wang, Yunxiu
    Huang, Xianzhang
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2022, 482
  • [50] State-of-the-art of serum testosterone measurement by isotope dilution-liquid chromatography-tandem mass spectrometry
    Thienpont, Linda M.
    Van Uytfanghe, Katleen
    Blincko, Stuart
    Ramsay, Carol S.
    Xie, Hui
    Doss, Robert C.
    Keevil, Brian G.
    Owen, Laura J.
    Rockwood, Alan L.
    Kushnir, Mark M.
    Chun, Kelly Y.
    Chandler, Donald W.
    Field, Helen P.
    Sluss, Patrick M.
    CLINICAL CHEMISTRY, 2008, 54 (08) : 1290 - 1297