Radiation dose vs. image quality for low-dose CT protocols of the head for maxillofacial surgery and oral implant planning

被引:46
|
作者
Loubele, M
Jacobs, R
Maes, F
Schutyser, F
Debaveye, D
Bogaerts, R
Coudyzer, W
Vandermeulen, D
van Cleynenbreugel, J
Marchal, G
Suetens, P
机构
[1] Katholieke Univ Leuven, Univ Hosp Gasthuisberg, Med Image Compt ESAT, PSI, B-3000 Louvain, Belgium
[2] Katholieke Univ Leuven, Oral Imaging Ctr, Sch Dent Oral Pathol & Maxillofacial Surg, B-3000 Louvain, Belgium
[3] Medicim NV, B-9100 St Niklaas, Belgium
[4] Katholieke Univ Leuven, Univ Hosp Gasthuisberg, Unit Person Dosemetry Radiat Protect, B-3000 Louvain, Belgium
[5] Katholieke Univ Leuven, Univ Hosp Gasthuisberg, Dept Radiol, B-3000 Louvain, Belgium
关键词
D O I
10.1093/rpd/nci749
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The goal of this study was to determine the acquisition parameters for a low-dose multi-slice CT protocol and to compare the effective dose and the image quality of this low-dose protocol with the image quality of a clinical multi-slice CT protocol, routinely used for visualisation of the head. The low-dose protocol was derived from a clinical multi-slice CT protocol by lowering mA s and kV and increasing the pitch. The low-dose protocol yielded a dose reduction from 1.5 to 0.18 mSv for a multi-slice CT scan of the whole head, whereas noise in the low-dose CT images was increased. For bone segmentation, noise could be reduced by use of a non-linear edge preserving smoothing filter. Tests on ESP and skull phantom indicated that the accuracy of the measurements on low-dose CT is acceptable for image-based planning of maxillofacial and oral implant surgery, reducing the dose by a factor of 8.
引用
收藏
页码:211 / 216
页数:6
相关论文
共 50 条
  • [31] CT radiation dose and image quality
    Payne, JT
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2005, 43 (06) : 953 - +
  • [32] THE EFFECT OF LOW-DOSE RADIATION CT PROTOCOLS UPON URETERAL STONE DETECTION
    Koning, J. L.
    Jellison, F.
    Smith, J.
    Heldt, J.
    Spengler, N.
    Nicolay, L.
    Millard, W.
    Saaty, H.
    Ruckle, H.
    Baldwin, D. D.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2009, 57 (01) : 146 - 146
  • [33] Low-dose CT angiography of the abdominal aorta and reduced contrast medium volume: Assessment of image quality and radiation dose
    Nijhof, W. H.
    Baltussen, E. J. M.
    Kant, I. M. J.
    Jager, G. J.
    Slump, C. H.
    Rutten, M. J. C. M.
    CLINICAL RADIOLOGY, 2016, 71 (01) : 64 - 73
  • [34] Iterative Reconstruction for Head CT: Effects on Radiation Dose and Image Quality
    Rivers-Bowerman, Michael D.
    Shankar, Jai Jai Shiva
    CANADIAN JOURNAL OF NEUROLOGICAL SCIENCES, 2014, 41 (05) : 620 - 625
  • [35] Comparison of two different GSI scanning protocols in head and neck CT angiography: Image quality and radiation dose
    Zhang, Tianle
    Zhao, Sai
    Liu, Yiwen
    Liu, Zhichao
    Ma, Zepeng
    Zuo, Ziwei
    Zhao, Yongxia
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2022, 30 (04) : 689 - 696
  • [36] Evaluation of dose and image in low-dose SPECT-CT
    Iimori, T.
    Fujibuchi, T.
    Sato, H.
    Sawada, K.
    Kasahara, T.
    Abe, Y.
    Yamagishi, Y.
    Ishii, T.
    Kato, H.
    Yanagawa, N.
    Kikawa, T.
    Uchida, Y.
    Itou, H.
    Kuwabara, Y.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S487 - S487
  • [37] A multi-institutional assessment of low-dose protocols in chest computed tomography: Dose and image quality
    Tonkopi, Elena
    Tetteh, Mercy Afadzi
    Gunn, Catherine
    Ashraf, Haseem
    Rusten, Sigrid Lia
    Safi, Perkhah
    Tinsoe, Nora Suu
    Colford, Kylie
    Ouellet, Olivia
    Naimi, Salma
    Johansen, Safora
    ACTA RADIOLOGICA OPEN, 2024, 13 (01)
  • [38] Standard-dose vs. low-dose CT protocols in the evaluation of localized lung lesions: Capability for lesion characterization-iLEAD study
    Kubo, Takeshi
    Ohno, Yoshiharu
    Takenaka, Daisuke
    Nishino, Mizuki
    Gautam, Shiva
    Sugimura, Kazuro
    Kauczor, Hans Ulrich
    Hatabu, Hiroto
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2016, 3 : 67 - 73
  • [39] Not Every Low-Dose Is Low-Dose: Impact of Revising Low-Dose CT Protocol on Mean Effective Radiation Exposure
    Deyirmendjian, Claudia
    Lee, Seohyuk
    Noureldin, Yasser A.
    Hegyi, Gyorgy
    Stein, Lawrence
    Artho, Giovanni
    Andonian, Sero
    JOURNAL OF ENDOUROLOGY, 2022, 36 (06) : 835 - 840
  • [40] LOW-DOSE RADIATION - RISKS VS BENEFITS
    UPTON, AC
    POSTGRADUATE MEDICINE, 1981, 70 (06) : 34 - &