Low-dose CT angiography of the abdominal aorta and reduced contrast medium volume: Assessment of image quality and radiation dose

被引:30
|
作者
Nijhof, W. H. [1 ,3 ]
Baltussen, E. J. M. [1 ]
Kant, I. M. J. [1 ]
Jager, G. J. [2 ]
Slump, C. H. [3 ]
Rutten, M. J. C. M. [2 ]
机构
[1] Univ Twente, Inst Biomed Technol & Tech Med, MIRA, Drienerlolaan 5, NL-7522 NB Enschede, Netherlands
[2] Jeroen Bosch Hosp, Dept Radiol, Henri Dunantstr 1, NL-5223 GZ Shertogenbosch, Netherlands
[3] Univ Twente, Dept Elect Engn, Signals & Syst, NL-7500 AE Enschede, Netherlands
关键词
TUBE VOLTAGE SELECTION; INDUCED NEPHROPATHY; CHEST CT; 100; KVP; REDUCTION; SCAN;
D O I
10.1016/j.crad.2015.10.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To determine the effect of using 80 kV tube voltage and a reduced amount of contrast medium on the image quality and radiation dose of computed tomography angiography (CTA) of the abdominal aorta. MATERIALS AND METHODS: Patients who were referred for a CTA examination of the abdominal aorta were included in this technical efficacy study. Thirty patients were divided randomly into two groups. Fifteen patients underwent a dual-energy CT (DECT) protocol (Group A). Fifteen patients were scanned with the use of an automated tube potential selection algorithm tool (Group B). In both protocols, a test bolus injection of 10 ml ioversol (350 mg iodine/ml) was used, followed by 20 ml of 1:1 saline-diluted contrast medium. Quantitative analysis comprised determination of the mean attenuation and contrast-to-noise ratio. Qualitative image analysis was performed independently by five radiologists. The estimated radiation dose in terms of CT dose index and effective dose was recorded and compared with a standard 120 kV protocol. RESULTS: In Group B, six patients underwent CTA at 80 kV, seven patients underwent CTA at 100 kV and two patients underwent CTA at 120 kV. The mean contrast-enhancement values of Group A (80 kV) and the 80 kV subgroup of Group B were 16.5% and 27.6% higher compared to the 100 kV subgroup of Group B, these differences were, however, not significant. There were no significant differences in mean image quality between groups. In patients undergoing CTA at 80 kV the effective dose decreased by up to 51.3% compared to a conventional 120 kVCTA protocol. CONCLUSIONS: The findings of this study support the hypothesis that 80 kV in CTA of the abdominal aorta can reliably be used with only 30 ml contrast medium in total and a 50% reduction in radiation dose. The overall image quality was diagnostically adequate; however, it appeared to be suboptimal in patients with a BMI above 28 kg/m(2). (C) 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:64 / 73
页数:10
相关论文
共 50 条
  • [1] Low-Dose CT Angiography: Which Contrast Medium?
    Iezzi, Roberto
    Bonomo, Lorenzo
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (04) : W660 - W660
  • [2] Low-Dose CT Angiography: Which Contrast Medium? Reply
    Faggioni, Lorenzo
    Neri, Emanuele
    Bartolozzi, Carlo
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (04) : W661 - W661
  • [3] Low-dose CT angiography of the lower extremities: a comparison study of image quality and radiation dose
    Park, S.
    Park, S. H.
    Hwang, J. H.
    Kim, J. H.
    Lee, K. H.
    Shin, J. H.
    Pak, S. Y.
    Kang, J. M.
    [J]. CLINICAL RADIOLOGY, 2021, 76 (02) : 156.e19 - 156.e26
  • [4] Low kV settings CT angiography (CTA) with low dose contrast medium volume protocol in the assessment of thoracic and abdominal aorta disease: a feasibility study
    Ippolito, D.
    Franzesi, C. Talei
    Fior, D.
    Bonaffini, P. A.
    Minutolo, O.
    Sironi, S.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1049):
  • [5] Evaluating Image Quality and Radiation Dose in Low-Dose Thoraco-Abdominal CT Angiography with a Tin Filter for Patients with Aortic Disease
    Oh, Chang Hoon
    Cho, Soo Buem
    Kwon, Hyeyoung
    [J]. JOURNAL OF CLINICAL MEDICINE, 2024, 13 (04)
  • [6] CT ANGIOGRAPHY WITH LOW-DOSE CONTRAST MATERIAL
    RAEL, JR
    CHAMPLIN, AM
    SANDERS, JA
    RUPP, FW
    ORRISON, WW
    [J]. RADIOLOGY, 1995, 197 : 490 - 491
  • [7] Improvement of Image Quality of Low Radiation Dose Abdominal CT by Increasing Contrast Enhancement
    Watanabe, Haruo
    Kanematsu, Masayuki
    Miyoshi, Toshiharu
    Goshima, Satoshi
    Kondo, Hiroshi
    Moriyama, Noriyuki
    Bae, Kyongtae T.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (04) : 986 - 992
  • [8] CORONARY CT ANGIOGRAPHY USING ULTRA-LOW DOSE CONTRAST MEDIA: RADIATION DOSE AND IMAGE QUALITY
    Komatsu, Sei
    Imai, Atsuko
    Kodama, Kazuhisa
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (13) : E1357 - E1357
  • [9] Impact of 80 kVp with iterative reconstruction algorithm and low-dose contrast medium on the image quality of craniocervical CT angiography
    Chen, Po-An
    Chen, Chih-Wei
    Chou, Chiung-Chen
    Fu, Jui-Hsun
    Wang, Po-Chin
    Hsu, Shuo-Hsiu
    Lai, Ping-Hong
    [J]. CLINICAL IMAGING, 2020, 68 (68) : 124 - 130
  • [10] Low-dose CT coronary angiography matchs regular-dose in image quality
    Bayol, A. P.
    Vallejos, J. A.
    Peloso, R. E.
    Aguero, M. A.
    Obregon, R.
    Zarza, A. C.
    Collante Bohle, M. A.
    Sandoval, D. H.
    Pozzer, P. A.
    Parras, J. I.
    [J]. EUROPEAN HEART JOURNAL, 2009, 30 : 489 - 489