Evaluating Image Quality and Radiation Dose in Low-Dose Thoraco-Abdominal CT Angiography with a Tin Filter for Patients with Aortic Disease

被引:0
|
作者
Oh, Chang Hoon [1 ]
Cho, Soo Buem [2 ]
Kwon, Hyeyoung [3 ]
机构
[1] Ewha Womans Univ, Ewha Womans Mokdong Hosp, Coll Med, Dept Radiol, Seoul 07985, South Korea
[2] Ewha Womans Univ, Ewha Womans Seoul Hosp, Coll Med, Dept Radiol, Seoul 07804, South Korea
[3] Chungnam Natl Univ, Chungnam Univ Hosp, Sch Med, Dept Radiol, Daejeon 35015, South Korea
关键词
tin filter; thoraco-abdominal CT angiography; radiation exposure; image quality; diagnostic imaging; SPECTRAL SHAPING CT; ACCURACY; VOLTAGE;
D O I
10.3390/jcm13040996
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We aimed to compared radiation exposure and image quality between tin-filter-based and standard dose thoraco-abdominal computed tomography angiography (TACTA) protocols, aiming to address a gap in the existing literature. Methods: In this retrospective study, ninety consecutive patients undergoing TACTA were included. Of these, 45 followed a routine standard-dose protocol (ST100kV), and 45 underwent a low-dose protocol with a tin filter (TF100kV). Radiation metrics were compared. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM) were calculated for the thoracic and abdominal aorta and right common iliac artery. Two independent readers assessed the image noise, image contrast, sharpness, and subjective image quality. Results: The mean dose for the TF100kV group was significantly lower (DLP 128.25 +/- 18.18 mGy*cm vs. 662.75 +/- 181.29, p < 0.001; CTDIvol 1.83 +/- 0.25 mGy vs. 9.28 +/- 2.17, p = 0.001), with an effective dose close to 2.3 mSv (2.31 +/- 0.33 mSv; p < 0.001). The TF100kV group demonstrated greater dose efficiency (FOM, thoracic aorta: 36.70 +/- 22.77 vs. 13.96 +/- 13.18 mSv(-1), p < 0.001) compared to the ST100kV group. Conclusions: Dedicated low-dose TACTA using a tin filter can significantly reduce the radiation dose while maintaining sufficient diagnostic image quality.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Low-dose CT angiography of the abdominal aorta and reduced contrast medium volume: Assessment of image quality and radiation dose
    Nijhof, W. H.
    Baltussen, E. J. M.
    Kant, I. M. J.
    Jager, G. J.
    Slump, C. H.
    Rutten, M. J. C. M.
    [J]. CLINICAL RADIOLOGY, 2016, 71 (01) : 64 - 73
  • [2] Low-dose CT angiography of the lower extremities: a comparison study of image quality and radiation dose
    Park, S.
    Park, S. H.
    Hwang, J. H.
    Kim, J. H.
    Lee, K. H.
    Shin, J. H.
    Pak, S. Y.
    Kang, J. M.
    [J]. CLINICAL RADIOLOGY, 2021, 76 (02) : 156.e19 - 156.e26
  • [3] Low-dose thoraco-abdominal irradiation for the treatment of refractory chronic GvHD.
    Guardiola, P
    Fernandez, G
    Girinski, T
    Socie, G
    Ribaud, P
    Esperou, H
    Gluckman, E
    Devergie, A
    [J]. BLOOD, 2002, 100 (11) : 846A - 847A
  • [4] Low-dose CT coronary angiography matchs regular-dose in image quality
    Bayol, A. P.
    Vallejos, J. A.
    Peloso, R. E.
    Aguero, M. A.
    Obregon, R.
    Zarza, A. C.
    Collante Bohle, M. A.
    Sandoval, D. H.
    Pozzer, P. A.
    Parras, J. I.
    [J]. EUROPEAN HEART JOURNAL, 2009, 30 : 489 - 489
  • [5] Low-dose thoraco-abdominal irradiation for the treatment of refractory chronic graft-versus-host disease
    Robin, M
    Guardiola, P
    Girínsky, T
    Hernandez, G
    Esperou, H
    Ribaud, P
    Rocha, W
    Garnier, F
    Socié, G
    Gluckman, E
    Devergie, A
    [J]. BONE MARROW TRANSPLANTATION, 2005, 35 : S43 - S43
  • [6] Low-Dose Three-Dimensional Rotational Angiography for Evaluating Intracranial Aneurysms: Analysis of Image Quality and Radiation Dose
    Ki, Hee Jong
    Kim, Bum-Soo
    Kim, Jun-Ki
    Choi, Jai Ho
    Shin, Yong Sam
    Choi, Yangsean
    Shin, Na-Young
    Jang, Jinhee
    Ahn, Kook-Jin
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2022, 23 (02) : 256 - 263
  • [7] Application of Aortic Computed Tomography Angiography with Low Radiation Dose: Assessment of Image Quality and Radiation Dose
    Liu, Jianhua
    Li, Long
    Zhang, Yan
    Yuan, Qinghai
    Sun, Yong
    [J]. 2012 IEEE FIFTH INTERNATIONAL CONFERENCE ON ADVANCED COMPUTATIONAL INTELLIGENCE (ICACI), 2012, : 148 - 151
  • [8] Low-Dose Abdominal CT for Evaluating Suspected Appendicitis
    Kim, Kyuseok
    Kim, Young Hoon
    Kim, So Yeon
    Kim, Suyoung
    Lee, Yoon Jin
    Kim, Kwang Pyo
    Lee, Hye Seung
    Ahn, Soyeon
    Kim, Taeyun
    Hwang, Seung-sik
    Song, Ki Jun
    Kang, Sung-Bum
    Kim, Duck-Woo
    Park, Seong Ho
    Lee, Kyoung Ho
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2012, 366 (17): : 1596 - 1605
  • [9] Low-dose thoraco-abdominal irradiation for the treatment of chronic graft versus host disease (GvHD):: a case report
    Martinez, S.
    Treutwein, M.
    Pohl, E.
    Bogner, L.
    Hipp, M.
    Schaefer, C.
    Holler, E.
    Koelbl, O.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2007, 183 : 131 - 131
  • [10] Low-Dose CT Examinations in Crohn's Disease: Impact on Image Quality, Diagnostic Performance, and Radiation Dose
    Kambadakone, Avinash R.
    Prakash, Priyanka
    Hahn, Peter F.
    Sahani, Dushyant V.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (01) : 78 - 88