Low-Dose CT Examinations in Crohn's Disease: Impact on Image Quality, Diagnostic Performance, and Radiation Dose

被引:59
|
作者
Kambadakone, Avinash R. [1 ]
Prakash, Priyanka [1 ]
Hahn, Peter F. [1 ]
Sahani, Dushyant V. [1 ]
机构
[1] Massachusetts Gen Hosp, Div Abdominal Imaging & Intervent Radiol, Dept Radiol, Boston, MA 02114 USA
关键词
Crohn's disease; MDCT; noise index; radiation dose; INFLAMMATORY-BOWEL-DISEASE; TUBE CURRENT MODULATION; NOISE-REDUCTION FILTERS; MULTIDETECTOR CT; FOLLOW-THROUGH; CAPSULE ENDOSCOPY; ABDOMINAL CT; ENTEROGRAPHY; EXPOSURE; EPIDEMIOLOGY;
D O I
10.2214/AJR.09.3420
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of this study was to evaluate the image quality and diagnostic performance of simulated low-dose MDCT examinations in patients with Crohn's disease. MATERIALS AND METHODS. Thirty-five MDCT examinations from 25 patients (14 males and 11 females; age range, 16-86 years) with known or suspected Crohn's disease were retrospectively evaluated. The MDCT images (5 mm thickness) were modified by artificially introducing noise using volume CT noise simulation software to simulate low-dose MDCT data acquired with noise indexes (NIs) of 18-35. The 175 MDCT image data sets generated were then randomized and reviewed by two readers to assess the subjective image quality and diagnostic accuracy for confidently detecting Crohn's disease findings on a 5-point scale (1, definitely absent; 5, definitely present). The image quality, diagnostic performance, and radiation dose from the original MDCT examinations served as a reference standard for comparison. RESULTS. The simulated low-dose CT images with elevated NIs of 18-25 yielded optimal image quality and concordant diagnostic accuracy with standard-dose scans with a mean baseline volume CT dose index of 16 +/- 3.34 (SD) mGy (image quality score, 4-4.9 vs 4.95, respectively; p = 0.4). Images simulating NIs of 30-35 were considered degraded because of excessive image noise and presented lower diagnostic performance (range of image quality score, 3-3.6; weighted. = 0.25-0.37; p < 0.001). Diagnostic performance and reader confidence for the determination of Crohn's disease manifestations in cases in which the reference standard was positive were higher at NIs of = 25 compared with NI of 30 (reader confidence score, 4.5 vs 3.6, respectively; p < 0.05) and an NI of 35 (3.2, p < 0.05). Compared with the standard-dose examination, a 31-64% reduction in radiation dose was estimated for NI levels of 18-25, which corresponds to image noise of 19-27 HU in subcutaneous fat. CONCLUSION. Processed MDCT images with the introduction of noise to simulate low-dose MDCT examinations with NI levels of 18-25 allows substantial dose reduction for CT examinations in Crohn's disease without compromising diagnostic information.
引用
收藏
页码:78 / 88
页数:11
相关论文
共 50 条
  • [1] Radiation dose and image quality in head CT examinations
    Huda, W
    Chang, J
    Lieberman, KA
    Roskopf, ML
    [J]. RADIOLOGY, 2001, 221 : 160 - 160
  • [2] Image Quality and Diagnostic Performance of Low-Dose Liver CT with Deep Learning Reconstruction versus Standard-Dose CT
    Lee, Dong Ho
    Lee, Jeong Min
    Lee, Chang Hee
    Afat, Saif
    Othman, Ahmed
    [J]. RADIOLOGY-ARTIFICIAL INTELLIGENCE, 2024, 6 (02)
  • [3] Low-dose CT angiography of the lower extremities: a comparison study of image quality and radiation dose
    Park, S.
    Park, S. H.
    Hwang, J. H.
    Kim, J. H.
    Lee, K. H.
    Shin, J. H.
    Pak, S. Y.
    Kang, J. M.
    [J]. CLINICAL RADIOLOGY, 2021, 76 (02) : 156.e19 - 156.e26
  • [4] Low-dose, volumetric helical CT - Image quality, radiation dose, and usefulness for evaluation of bronchiectasis
    Jung, KJ
    Lee, KS
    Kim, SY
    Kim, TS
    Pyeun, YS
    Lee, JY
    [J]. INVESTIGATIVE RADIOLOGY, 2000, 35 (09) : 557 - 563
  • [5] Image quality assessment in low-dose COVID-19 chest CT examinations
    Feghali, Joelle A.
    Russo, Roberta A.
    Mamou, Adel
    Lorentz, Axel
    Cantarinha, Alfredo
    Bellin, Marie-France
    Meyrignac, Olivier
    [J]. ACTA RADIOLOGICA, 2024, 65 (01) : 3 - 13
  • [6] Improved image quality of low-dose thoracic CT examinations with a new postprocessing software
    Martinsen, Anne Catrine Traegde
    Saether, Hilde Kjernlie
    Olsen, Dag Rune
    Wolff, Per Aage
    Skaane, Per
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (03): : 250 - 258
  • [7] Effect of Multislit Collimator Motion On SparseCT Image Quality for Low-Dose CT Examinations
    Chen, B.
    Kobler, E.
    Allmendinger, T.
    Sodickson, A.
    Sodickson, D.
    Otazo, R.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E504 - E505
  • [8] Low-Dose Computed Tomography for the Optimization of Radiation Dose Exposure in Patients with Crohn's Disease
    Kavanagh, Richard G.
    O'Grady, John
    Carey, Brian W.
    McLaughlin, Patrick D.
    O'Neill, Siobhan B.
    Maher, Michael M.
    O'Connor, Owen J.
    [J]. GASTROENTEROLOGY RESEARCH AND PRACTICE, 2018, 2018
  • [9] Impact of Morphotype on Image Quality and Diagnostic Performance of Ultra-Low-Dose Chest CT
    Ortlieb, Anne-Claire
    Labani, Aissam
    Severac, Francois
    Jeung, Mi-Young
    Roy, Catherine
    Ohana, Mickael
    [J]. JOURNAL OF CLINICAL MEDICINE, 2021, 10 (15)
  • [10] Not Every Low-Dose Is Low-Dose: Impact of Revising Low-Dose CT Protocol on Mean Effective Radiation Exposure
    Deyirmendjian, Claudia
    Lee, Seohyuk
    Noureldin, Yasser A.
    Hegyi, Gyorgy
    Stein, Lawrence
    Artho, Giovanni
    Andonian, Sero
    [J]. JOURNAL OF ENDOUROLOGY, 2022, 36 (06) : 835 - 840