Low-Dose CT Examinations in Crohn's Disease: Impact on Image Quality, Diagnostic Performance, and Radiation Dose

被引:59
|
作者
Kambadakone, Avinash R. [1 ]
Prakash, Priyanka [1 ]
Hahn, Peter F. [1 ]
Sahani, Dushyant V. [1 ]
机构
[1] Massachusetts Gen Hosp, Div Abdominal Imaging & Intervent Radiol, Dept Radiol, Boston, MA 02114 USA
关键词
Crohn's disease; MDCT; noise index; radiation dose; INFLAMMATORY-BOWEL-DISEASE; TUBE CURRENT MODULATION; NOISE-REDUCTION FILTERS; MULTIDETECTOR CT; FOLLOW-THROUGH; CAPSULE ENDOSCOPY; ABDOMINAL CT; ENTEROGRAPHY; EXPOSURE; EPIDEMIOLOGY;
D O I
10.2214/AJR.09.3420
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of this study was to evaluate the image quality and diagnostic performance of simulated low-dose MDCT examinations in patients with Crohn's disease. MATERIALS AND METHODS. Thirty-five MDCT examinations from 25 patients (14 males and 11 females; age range, 16-86 years) with known or suspected Crohn's disease were retrospectively evaluated. The MDCT images (5 mm thickness) were modified by artificially introducing noise using volume CT noise simulation software to simulate low-dose MDCT data acquired with noise indexes (NIs) of 18-35. The 175 MDCT image data sets generated were then randomized and reviewed by two readers to assess the subjective image quality and diagnostic accuracy for confidently detecting Crohn's disease findings on a 5-point scale (1, definitely absent; 5, definitely present). The image quality, diagnostic performance, and radiation dose from the original MDCT examinations served as a reference standard for comparison. RESULTS. The simulated low-dose CT images with elevated NIs of 18-25 yielded optimal image quality and concordant diagnostic accuracy with standard-dose scans with a mean baseline volume CT dose index of 16 +/- 3.34 (SD) mGy (image quality score, 4-4.9 vs 4.95, respectively; p = 0.4). Images simulating NIs of 30-35 were considered degraded because of excessive image noise and presented lower diagnostic performance (range of image quality score, 3-3.6; weighted. = 0.25-0.37; p < 0.001). Diagnostic performance and reader confidence for the determination of Crohn's disease manifestations in cases in which the reference standard was positive were higher at NIs of = 25 compared with NI of 30 (reader confidence score, 4.5 vs 3.6, respectively; p < 0.05) and an NI of 35 (3.2, p < 0.05). Compared with the standard-dose examination, a 31-64% reduction in radiation dose was estimated for NI levels of 18-25, which corresponds to image noise of 19-27 HU in subcutaneous fat. CONCLUSION. Processed MDCT images with the introduction of noise to simulate low-dose MDCT examinations with NI levels of 18-25 allows substantial dose reduction for CT examinations in Crohn's disease without compromising diagnostic information.
引用
收藏
页码:78 / 88
页数:11
相关论文
共 50 条
  • [21] Diagnostic performance of low-radiation-dose and low-contrast-dose (double low-dose) coronary CT angiography for coronary artery stenosis
    Zhang, Wei
    Ba, Zhaogui
    Wang, Zhenqiang
    Lv, Huaying
    Zhao, Jun
    Zhang, Yonghua
    Zhang, Feixue
    Song, Lei
    [J]. MEDICINE, 2018, 97 (34)
  • [22] Low-dose liver CT: image quality and diagnostic accuracy of deep learning image reconstruction algorithm
    Damiano Caruso
    Domenico De Santis
    Antonella Del Gaudio
    Gisella Guido
    Marta Zerunian
    Michela Polici
    Daniela Valanzuolo
    Dominga Pugliese
    Raffaello Persechino
    Antonio Cremona
    Luca Barbato
    Andrea Caloisi
    Elsa Iannicelli
    Andrea Laghi
    [J]. European Radiology, 2024, 34 : 2384 - 2393
  • [23] Low-dose liver CT: image quality and diagnostic accuracy of deep learning image reconstruction algorithm
    Caruso, Damiano
    De Santis, Domenico
    Del Gaudio, Antonella
    Guido, Gisella
    Zerunian, Marta
    Polici, Michela
    Valanzuolo, Daniela
    Pugliese, Dominga
    Persechino, Raffaello
    Cremona, Antonio
    Barbato, Luca
    Caloisi, Andrea
    Iannicelli, Elsa
    Laghi, Andrea
    [J]. EUROPEAN RADIOLOGY, 2024, 34 (04) : 2384 - 2393
  • [24] Improved Image Quality of Low-Dose CT Pulmonary Angiograms
    Chen, Eric L.
    Ross, Jeremy A.
    Grant, Christopher
    Wilbur, Andrew
    Mehta, Nikhil
    Hart, Eric
    Mar, Winnie A.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2017, 14 (05) : 648 - 653
  • [25] Low-dose CT coronary angiography matchs regular-dose in image quality
    Bayol, A. P.
    Vallejos, J. A.
    Peloso, R. E.
    Aguero, M. A.
    Obregon, R.
    Zarza, A. C.
    Collante Bohle, M. A.
    Sandoval, D. H.
    Pozzer, P. A.
    Parras, J. I.
    [J]. EUROPEAN HEART JOURNAL, 2009, 30 : 489 - 489
  • [26] CT radiation dose and image quality
    Payne, JT
    [J]. RADIOLOGIC CLINICS OF NORTH AMERICA, 2005, 43 (06) : 953 - +
  • [27] Low-dose naltrexone as a treatment for active Crohn's disease
    Smith, Jill P.
    Stock, Heather E.
    Bingaman, Sandra I.
    Mauger, David T.
    Zagon, Ian S.
    [J]. GASTROENTEROLOGY, 2006, 130 (04) : A218 - A218
  • [28] THE IMPACT OF OBESITY ON ABDOMINAL CT RADIATION DOSE AND IMAGE QUALITY
    Qurashi, Abdulaziz A.
    Rainford, Louise A.
    Alshamrani, Khalid M.
    Foley, Shane J.
    [J]. RADIATION PROTECTION DOSIMETRY, 2019, 185 (01) : 25 - 34
  • [29] Diagnostic Reference Level of Radiation Dose and Image Quality among Paediatric CT Examinations in A Tertiary Hospital in Malaysia
    Muhammad, Nor Azura
    Karim, Muhammad Khalis Abdul
    Abu Hassan, Hasyma
    Kamarudin, Mazliana Ahmad
    Wong, Jeannie Hsiu Ding
    Ng, Kwan Hoong
    [J]. DIAGNOSTICS, 2020, 10 (08)
  • [30] Low-dose CT angiography of the abdominal aorta and reduced contrast medium volume: Assessment of image quality and radiation dose
    Nijhof, W. H.
    Baltussen, E. J. M.
    Kant, I. M. J.
    Jager, G. J.
    Slump, C. H.
    Rutten, M. J. C. M.