Low-dose CT angiography of the abdominal aorta and reduced contrast medium volume: Assessment of image quality and radiation dose

被引:30
|
作者
Nijhof, W. H. [1 ,3 ]
Baltussen, E. J. M. [1 ]
Kant, I. M. J. [1 ]
Jager, G. J. [2 ]
Slump, C. H. [3 ]
Rutten, M. J. C. M. [2 ]
机构
[1] Univ Twente, Inst Biomed Technol & Tech Med, MIRA, Drienerlolaan 5, NL-7522 NB Enschede, Netherlands
[2] Jeroen Bosch Hosp, Dept Radiol, Henri Dunantstr 1, NL-5223 GZ Shertogenbosch, Netherlands
[3] Univ Twente, Dept Elect Engn, Signals & Syst, NL-7500 AE Enschede, Netherlands
关键词
TUBE VOLTAGE SELECTION; INDUCED NEPHROPATHY; CHEST CT; 100; KVP; REDUCTION; SCAN;
D O I
10.1016/j.crad.2015.10.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To determine the effect of using 80 kV tube voltage and a reduced amount of contrast medium on the image quality and radiation dose of computed tomography angiography (CTA) of the abdominal aorta. MATERIALS AND METHODS: Patients who were referred for a CTA examination of the abdominal aorta were included in this technical efficacy study. Thirty patients were divided randomly into two groups. Fifteen patients underwent a dual-energy CT (DECT) protocol (Group A). Fifteen patients were scanned with the use of an automated tube potential selection algorithm tool (Group B). In both protocols, a test bolus injection of 10 ml ioversol (350 mg iodine/ml) was used, followed by 20 ml of 1:1 saline-diluted contrast medium. Quantitative analysis comprised determination of the mean attenuation and contrast-to-noise ratio. Qualitative image analysis was performed independently by five radiologists. The estimated radiation dose in terms of CT dose index and effective dose was recorded and compared with a standard 120 kV protocol. RESULTS: In Group B, six patients underwent CTA at 80 kV, seven patients underwent CTA at 100 kV and two patients underwent CTA at 120 kV. The mean contrast-enhancement values of Group A (80 kV) and the 80 kV subgroup of Group B were 16.5% and 27.6% higher compared to the 100 kV subgroup of Group B, these differences were, however, not significant. There were no significant differences in mean image quality between groups. In patients undergoing CTA at 80 kV the effective dose decreased by up to 51.3% compared to a conventional 120 kVCTA protocol. CONCLUSIONS: The findings of this study support the hypothesis that 80 kV in CTA of the abdominal aorta can reliably be used with only 30 ml contrast medium in total and a 50% reduction in radiation dose. The overall image quality was diagnostically adequate; however, it appeared to be suboptimal in patients with a BMI above 28 kg/m(2). (C) 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:64 / 73
页数:10
相关论文
共 50 条
  • [21] Low-dose, volumetric helical CT - Image quality, radiation dose, and usefulness for evaluation of bronchiectasis
    Jung, KJ
    Lee, KS
    Kim, SY
    Kim, TS
    Pyeun, YS
    Lee, JY
    [J]. INVESTIGATIVE RADIOLOGY, 2000, 35 (09) : 557 - 563
  • [22] Image Quality in Reduced-Dose Coronary CT Angiography
    Gagarina, Nina V.
    Irwan, Roy
    Gordina, Galina
    Fominykh, Ekaterina
    Sijens, Paul E.
    [J]. ACADEMIC RADIOLOGY, 2011, 18 (08) : 984 - 990
  • [23] Diagnostic performance of low-radiation-dose and low-contrast-dose (double low-dose) coronary CT angiography for coronary artery stenosis
    Zhang, Wei
    Ba, Zhaogui
    Wang, Zhenqiang
    Lv, Huaying
    Zhao, Jun
    Zhang, Yonghua
    Zhang, Feixue
    Song, Lei
    [J]. MEDICINE, 2018, 97 (34)
  • [24] An audit of patient radiation in low-dose CT pulmonary angiography
    Genena, Amal M. Aziz
    Selim, Yasser Abdel Razek Mohamed
    [J]. EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2016, 47 (04): : 1423 - 1430
  • [25] Radiation dose in cardiac CT angiography: protocols and image quality
    Oliveira, L. C. G.
    Gottlieb, I.
    Rizzi, P.
    Lopes, R. T.
    Kodlulovich, S.
    [J]. RADIATION PROTECTION DOSIMETRY, 2013, 155 (01) : 73 - 80
  • [26] Radiation Dose and Image Quality at High-Pitch CT Angiography of the Aorta: Intraindividual and Interindividual Comparisons With Conventional CT Angiography
    Apfaltrer, Paul
    Hanna, E. Lexworth
    Schoepf, U. Joseph
    Spears, J. Reid
    Schoenberg, Stefan O.
    Fink, Christian
    Vliegenthart, Rozemarijn
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (06) : 1402 - 1409
  • [27] Image quality and radiation dose of renal perfusion CT with low-dose contrast agent: a comparison with conventional CT using a 320-row system
    Asayama, Y.
    Nishie, A.
    Ishigami, K.
    Ushijima, Y.
    Kakihara, D.
    Fujita, N.
    Morita, K.
    Ishimatsu, K.
    Takao, S.
    Honda, H.
    [J]. CLINICAL RADIOLOGY, 2019, 74 (08) : 650.e13 - 650.e18
  • [28] Low-dose CT of the paranasal sinuses with eye lens protection: effect on image quality and radiation dose
    Eike Hein
    Patrik Rogalla
    Randolph Klingebiel
    Bernd Hamm
    [J]. European Radiology, 2002, 12 : 1693 - 1696
  • [29] Low-dose CT of the paranasal sinuses with eye lens protection: effect on image quality and radiation dose
    Hein, E
    Rogalla, P
    Klingebiel, R
    Hamm, B
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (07) : 1693 - 1696
  • [30] THE IMPACT OF OBESITY ON ABDOMINAL CT RADIATION DOSE AND IMAGE QUALITY
    Qurashi, Abdulaziz A.
    Rainford, Louise A.
    Alshamrani, Khalid M.
    Foley, Shane J.
    [J]. RADIATION PROTECTION DOSIMETRY, 2019, 185 (01) : 25 - 34