Radiation dose vs. image quality for low-dose CT protocols of the head for maxillofacial surgery and oral implant planning

被引:46
|
作者
Loubele, M
Jacobs, R
Maes, F
Schutyser, F
Debaveye, D
Bogaerts, R
Coudyzer, W
Vandermeulen, D
van Cleynenbreugel, J
Marchal, G
Suetens, P
机构
[1] Katholieke Univ Leuven, Univ Hosp Gasthuisberg, Med Image Compt ESAT, PSI, B-3000 Louvain, Belgium
[2] Katholieke Univ Leuven, Oral Imaging Ctr, Sch Dent Oral Pathol & Maxillofacial Surg, B-3000 Louvain, Belgium
[3] Medicim NV, B-9100 St Niklaas, Belgium
[4] Katholieke Univ Leuven, Univ Hosp Gasthuisberg, Unit Person Dosemetry Radiat Protect, B-3000 Louvain, Belgium
[5] Katholieke Univ Leuven, Univ Hosp Gasthuisberg, Dept Radiol, B-3000 Louvain, Belgium
关键词
D O I
10.1093/rpd/nci749
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The goal of this study was to determine the acquisition parameters for a low-dose multi-slice CT protocol and to compare the effective dose and the image quality of this low-dose protocol with the image quality of a clinical multi-slice CT protocol, routinely used for visualisation of the head. The low-dose protocol was derived from a clinical multi-slice CT protocol by lowering mA s and kV and increasing the pitch. The low-dose protocol yielded a dose reduction from 1.5 to 0.18 mSv for a multi-slice CT scan of the whole head, whereas noise in the low-dose CT images was increased. For bone segmentation, noise could be reduced by use of a non-linear edge preserving smoothing filter. Tests on ESP and skull phantom indicated that the accuracy of the measurements on low-dose CT is acceptable for image-based planning of maxillofacial and oral implant surgery, reducing the dose by a factor of 8.
引用
收藏
页码:211 / 216
页数:6
相关论文
共 50 条
  • [21] Reducing the radiation dose for low-dose CT of the paranasal sinuses using iterative reconstruction: Feasibility and image quality
    Bulla, Stefan
    Blanke, Philipp
    Hassepass, Frederike
    Krauss, Tobias
    Winterer, Jan Thorsten
    Breunig, Christine
    Langer, Mathias
    Pache, Gregor
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (09) : 2246 - 2250
  • [22] Sinogram-Affirmed Iterative Reconstruction of Low-Dose Chest CT: Effect on Image Quality and Radiation Dose
    Kalra, Mannudeep K.
    Woisetschlaeger, Mischa
    Dahlstroem, Nils
    Singh, Sarabjeet
    Digumarthy, Subbarao
    Do, Synho
    Pien, Homer
    Quick, Petter
    Schmidt, Bernhard
    Sedlmair, Martin
    Shepard, Jo-Anne O.
    Persson, Anders
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (02) : W235 - W244
  • [23] Iterative Reconstruction in Head CT: Image Quality of Routine and Low-Dose Protocols in Comparison with Standard Filtered Back-Projection
    Korn, A.
    Fenchel, M.
    Bender, B.
    Danz, S.
    Hauser, T. K.
    Ketelsen, D.
    Flohr, T.
    Claussen, C. D.
    Heuschmid, M.
    Ernemann, U.
    Brodoefel, H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (02) : 218 - 224
  • [24] Radiation exposure and image quality in staged low-dose protocols for coronary dual-source CT angiography: a randomized comparison
    Tobias Pflederer
    Josy Jakstat
    Mohamed Marwan
    Tiziano Schepis
    Sven Bachmann
    Axel Kuettner
    Katharina Anders
    Michael Lell
    Gerd Muschiol
    Dieter Ropers
    Werner G. Daniel
    Stephan Achenbach
    European Radiology, 2010, 20 : 1197 - 1206
  • [25] Radiation exposure and image quality in staged low-dose protocols for coronary dual-source CT angiography: a randomized comparison
    Pflederer, Tobias
    Jakstat, Josy
    Marwan, Mohamed
    Schepis, Tiziano
    Bachmann, Sven
    Kuettner, Axel
    Anders, Katharina
    Lell, Michael
    Muschiol, Gerd
    Ropers, Dieter
    Daniel, Werner G.
    Achenbach, Stephan
    EUROPEAN RADIOLOGY, 2010, 20 (05) : 1197 - 1206
  • [26] Improved Image Quality of Low-Dose CT Pulmonary Angiograms
    Chen, Eric L.
    Ross, Jeremy A.
    Grant, Christopher
    Wilbur, Andrew
    Mehta, Nikhil
    Hart, Eric
    Mar, Winnie A.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2017, 14 (05) : 648 - 653
  • [27] Pointers for Optimizing Radiation Dose in Head CT Protocols
    Singh, Sarabjeet
    Kalra, Mannudeep K.
    Thrall, James H.
    Mahesh, Mahadevappa
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2011, 8 (08) : 591 - 593
  • [28] Pediatric low-dose head CT: Image quality improvement using iterative model reconstruction
    Rabinowich, Aviad
    Shendler, Genady
    Ben-Sira, Liat
    Shiran, Shelly, I
    NEURORADIOLOGY JOURNAL, 2023, 36 (05): : 555 - 562
  • [29] Low-dose CT coronary angiography matchs regular-dose in image quality
    Bayol, A. P.
    Vallejos, J. A.
    Peloso, R. E.
    Aguero, M. A.
    Obregon, R.
    Zarza, A. C.
    Collante Bohle, M. A.
    Sandoval, D. H.
    Pozzer, P. A.
    Parras, J. I.
    EUROPEAN HEART JOURNAL, 2009, 30 : 489 - 489
  • [30] Comparison of low-dose vs. high-dose CT attenuation correction for brain PET
    Bai, Bing
    Hamill, James
    Esser, Peter
    Slifstein, Mark
    Mann, J.
    Parsey, Ramin
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50