Iterative Reconstruction in Head CT: Image Quality of Routine and Low-Dose Protocols in Comparison with Standard Filtered Back-Projection

被引:99
|
作者
Korn, A. [1 ]
Fenchel, M. [1 ]
Bender, B. [1 ]
Danz, S. [1 ]
Hauser, T. K. [1 ]
Ketelsen, D. [2 ]
Flohr, T. [3 ]
Claussen, C. D. [2 ]
Heuschmid, M. [2 ]
Ernemann, U. [1 ]
Brodoefel, H. [2 ]
机构
[1] Univ Tubingen, Dept Diagnost & Intervent Neuroradiol, D-72076 Tubingen, Germany
[2] Univ Tubingen, Dept Diagnost & Intervent Radiol, D-72076 Tubingen, Germany
[3] Siemens HealthCare, Computed Tomog Div, Forchheim, Germany
关键词
REDUCTION; RADIATION; CHEST;
D O I
10.3174/ajnr.A2749
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: IR has recently demonstrated its capacity to reduce noise and permit dose reduction in abdominal and thoracic CT applications. The purpose of our study was to assess the potential benefit of IR in head CT by comparing objective and subjective image quality with standard FBP at various dose levels. MATERIALS AND METHODS: Ninety consecutive patients were randomly assigned to undergo nonenhanced and contrast-enhanced head CT at a standard dose (320 mAs; CTDI, 60.1) or 15% (275 mAs; CTDI, 51.8) and 30% (225 mAs; CTDI, 42.3) dose reduction. All acquisitions were reconstructed with IR in image space, and FBP and images were assessed in terms of quantitative and qualitative 10. RESULTS: Compared with FBP, IR resulted in lower image noise (P <= .02), higher CNR (P <= .03), and improved subjective image quality (P <= .002) at all dose levels. While degradation of objective and subjective IQ at 15% dose reduction was fully compensated by IR (CNR, 1.98 +/- 0.4 at 320 mAs with FBP versus 2.05 +/- 0.4 at 275 mAs with IR; IQ, 1.8 versus 1.7), IQ was considerably poorer at 70% standard dose despite using the iterative approach (CNR, 1.98 +/- 0.3 at 320 mAs with FBP versus 1.85 +/- 0.4 at 225 mAs with IR, P = .18;10, 1.8 versus 2.2, P = .03). Linear regression analysis of CNR against tube current suggests that standard CNR may be obtained until approximately 20.4% dose reduction when IR is used. CONCLUSIONS: Compared with conventional FBP, IR of head CT is associated with significant improvement of objective and subjective IQ and may allow dose reductions in the range of 20% without compromising standard image quality.
引用
收藏
页码:218 / 224
页数:7
相关论文
共 50 条
  • [1] Evaluation of dose reduction and image quality in CT colonography: Comparison of low-dose CT with iterative reconstruction and routine-dose CT with filtered back projection
    Koichi Nagata
    Masanori Fujiwara
    Hidenori Kanazawa
    Tomohiro Mogi
    Nao Iida
    Toru Mitsushima
    Alan T. Lefor
    Hideharu Sugimoto
    [J]. European Radiology, 2015, 25 : 221 - 229
  • [2] Evaluation of dose reduction and image quality in CT colonography: Comparison of low-dose CT with iterative reconstruction and routine-dose CT with filtered back projection
    Nagata, Koichi
    Fujiwara, Masanori
    Kanazawa, Hidenori
    Mogi, Tomohiro
    Iida, Nao
    Mitsushima, Toru
    Lefor, Alan T.
    Sugimoto, Hideharu
    [J]. EUROPEAN RADIOLOGY, 2015, 25 (01) : 221 - 229
  • [3] Patient dose and image quality in low-dose abdominal CT: a comparison between iterative reconstruction and filtered back projection
    Kataria, Bharti
    Smedby, Orjan
    [J]. ACTA RADIOLOGICA, 2013, 54 (05) : 540 - 548
  • [4] Comparison of Iterative Model Reconstruction versus Filtered Back-Projection in Pediatric Emergency Head CT: Dose, Image Quality, and Image-Reconstruction Times
    Southard, R. N.
    Bardo, D. M. E.
    Temkit, M. H.
    Thorkelson, M. A.
    Augustyn, R. A.
    Martinot, C. A.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (05) : 866 - 871
  • [5] Computed tomography of the cervical spine: comparison of image quality between a standard-dose and a low-dose protocol using filtered back-projection and iterative reconstruction
    Becce, Fabio
    Ben Salah, Yosr
    Verdun, Francis R.
    Vande Berg, Bruno C.
    Lecouvet, Frederic E.
    Meuli, Reto
    Omoumi, Patrick
    [J]. SKELETAL RADIOLOGY, 2013, 42 (07) : 937 - 945
  • [6] Computed tomography of the cervical spine: comparison of image quality between a standard-dose and a low-dose protocol using filtered back-projection and iterative reconstruction
    Fabio Becce
    Yosr Ben Salah
    Francis R. Verdun
    Bruno C. Vande Berg
    Frederic E. Lecouvet
    Reto Meuli
    Patrick Omoumi
    [J]. Skeletal Radiology, 2013, 42 : 937 - 945
  • [7] Coronary plaque detection in low-dose CT: comparison of iterative reconstruction and filtered back projection
    Schmid, J.
    Layritz, C.
    Marwan, M.
    Mitschke, M.
    Pflederer, T.
    Ropers, D.
    Achenbach, S.
    Schuhbaeck, A.
    [J]. EUROPEAN HEART JOURNAL, 2014, 35 : 624 - 624
  • [8] Abdominal CT: Comparison of Low-Dose CT With Adaptive Statistical Iterative Reconstruction and Routine-Dose CT With Filtered Back Projection in 53 Patients
    Sagara, Yoshiko
    Hara, Amy K.
    Pavlicek, William
    Silva, Alvin C.
    Paden, Robert G.
    Wu, Qing
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (03) : 713 - 719
  • [9] Iterative Reconstructions versus Filtered Back-Projection for Urinary Stone Detection in Low-Dose CT
    Winklehner, Anna
    Blume, Iris
    Winklhofer, Sebastian
    Eberli, Daniel
    Gnannt, Ralph
    Frauenfelder, Thomas
    Alkadhi, Hatem
    [J]. ACADEMIC RADIOLOGY, 2013, 20 (11) : 1429 - 1435
  • [10] Low-Dose Computed Tomography of the Chest Using Iterative Reconstruction Versus Filtered Back Projection: Comparison of Image Quality
    Lee, Youkyung
    Jin, Kwang Nam
    Lee, Nyoung Keun