Iterative Reconstruction in Head CT: Image Quality of Routine and Low-Dose Protocols in Comparison with Standard Filtered Back-Projection

被引:99
|
作者
Korn, A. [1 ]
Fenchel, M. [1 ]
Bender, B. [1 ]
Danz, S. [1 ]
Hauser, T. K. [1 ]
Ketelsen, D. [2 ]
Flohr, T. [3 ]
Claussen, C. D. [2 ]
Heuschmid, M. [2 ]
Ernemann, U. [1 ]
Brodoefel, H. [2 ]
机构
[1] Univ Tubingen, Dept Diagnost & Intervent Neuroradiol, D-72076 Tubingen, Germany
[2] Univ Tubingen, Dept Diagnost & Intervent Radiol, D-72076 Tubingen, Germany
[3] Siemens HealthCare, Computed Tomog Div, Forchheim, Germany
关键词
REDUCTION; RADIATION; CHEST;
D O I
10.3174/ajnr.A2749
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: IR has recently demonstrated its capacity to reduce noise and permit dose reduction in abdominal and thoracic CT applications. The purpose of our study was to assess the potential benefit of IR in head CT by comparing objective and subjective image quality with standard FBP at various dose levels. MATERIALS AND METHODS: Ninety consecutive patients were randomly assigned to undergo nonenhanced and contrast-enhanced head CT at a standard dose (320 mAs; CTDI, 60.1) or 15% (275 mAs; CTDI, 51.8) and 30% (225 mAs; CTDI, 42.3) dose reduction. All acquisitions were reconstructed with IR in image space, and FBP and images were assessed in terms of quantitative and qualitative 10. RESULTS: Compared with FBP, IR resulted in lower image noise (P <= .02), higher CNR (P <= .03), and improved subjective image quality (P <= .002) at all dose levels. While degradation of objective and subjective IQ at 15% dose reduction was fully compensated by IR (CNR, 1.98 +/- 0.4 at 320 mAs with FBP versus 2.05 +/- 0.4 at 275 mAs with IR; IQ, 1.8 versus 1.7), IQ was considerably poorer at 70% standard dose despite using the iterative approach (CNR, 1.98 +/- 0.3 at 320 mAs with FBP versus 1.85 +/- 0.4 at 225 mAs with IR, P = .18;10, 1.8 versus 2.2, P = .03). Linear regression analysis of CNR against tube current suggests that standard CNR may be obtained until approximately 20.4% dose reduction when IR is used. CONCLUSIONS: Compared with conventional FBP, IR of head CT is associated with significant improvement of objective and subjective IQ and may allow dose reductions in the range of 20% without compromising standard image quality.
引用
收藏
页码:218 / 224
页数:7
相关论文
共 50 条
  • [11] Pediatric Head CT Image Quality With Iterative Reconstruction Versus Filtered Back Projection
    Oberle, R.
    Kim, E.
    Wu, I.
    Ho, C.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [12] Low-Dose CT With the Adaptive Statistical Iterative Reconstruction V Technique in Abdominal Organ Injury: Comparison With Routine-Dose CT With Filtered Back Projection
    Lee, Nam Kyung
    Kim, Suk
    Hong, Seung BaeK
    Kim, Tae Un
    Ryu, Hwaseong
    Lee, Ji Won
    Kim, Jin You
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 213 (03) : 659 - 666
  • [13] Coronary CT angiography: Comparison of a novel iterative reconstruction with filtered back projection for reconstruction of low-dose CT-Initial experience
    Takx, Richard A. P.
    Schoepf, U. Joseph
    Moscariello, Antonio
    Das, Marco
    Rowe, Garrett
    Schoenberg, Stefan O.
    Fink, Christian
    Henzler, Thomas
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (02) : 275 - 280
  • [14] CT coronary angiography: Image quality with sinogram-affirmed iterative reconstruction compared with filtered back-projection
    Wang, R.
    Schoepf, U. J.
    Wu, R.
    Gibbs, K. P.
    Yu, W.
    Li, M.
    Zhang, Z.
    [J]. CLINICAL RADIOLOGY, 2013, 68 (03) : 272 - 278
  • [15] Image Quality Assessment of Standard- and Low-Dose Chest CT Using Filtered Back Projection, Adaptive Statistical Iterative Reconstruction, and Novel Model-Based Iterative Reconstruction Algorithms
    Vardhanabhuti, Varut
    Loader, Robert J.
    Mitchell, Grant R.
    Riordan, Richard D.
    Roobottom, Carl A.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (03) : 545 - 552
  • [16] Comparison of low-dose CT with adaptive statistical iterative reconstruction and conventional filtered back projection in whole body PET/CT
    Tang, Yongjin
    Ling, Xueying
    Xiao, Zeyu
    Shang JingJie
    Xu, Hao
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [17] Comparison of low-dose CT with adaptive statistical iterative reconstruction and conventional filtered back projection in whole body PET/CT
    Tang, Yongjin
    Ling, Xueying
    Xiao, Zeyu
    Shang JingJie
    Xu, Hao
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [18] Comparison study of image quality between filtered back projection and iterative reconstruction algorithm for dose reduction in chest CT
    Son, Junyoung
    Lee, Donghoon
    Jeon, Pil-Hyun
    Choi, Sunghoon
    Kim, Hyemi
    Kim, Hee-Joung
    [J]. INTERNATIONAL FORUM ON MEDICAL IMAGING IN ASIA 2019, 2019, 11050
  • [19] Low-Dose Chest Computed Tomography With Sinogram-Affirmed Iterative Reconstruction, Iterative Reconstruction in Image Space, and Filtered Back Projection: Studies on Image Quality
    Hwang, Hye Jeon
    Seo, Joon Beom
    Lee, Hyun Joo
    Lee, Sang Min
    Kim, Eun Young
    Oh, Sang Young
    Kim, Ji-Eun
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (04) : 610 - 617
  • [20] Superior objective and subjective image quality of deep learning reconstruction for low-dose abdominal CT imaging in comparison with model-based iterative reconstruction and filtered back projection
    Tamura, Akio
    Mukaida, Eisuke
    Ota, Yoshitaka
    Kamata, Masayoshi
    Abe, Shun
    Yoshioka, Kunihiro
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1123):