Application of a high-pressure gas semi-active resettable damper to the benchmark smart base-isolated building

被引:17
|
作者
Leavitt, John [1 ]
Bobrow, James E. [1 ]
Jabbari, Faryar [1 ]
Yang, Jann N. [1 ]
机构
[1] Univ Calif Irvine, Henry Samueli Sch Engn, Irvine, CA 92697 USA
来源
STRUCTURAL CONTROL & HEALTH MONITORING | 2006年 / 13卷 / 2-3期
关键词
resetting stiffness devices; semi-active control;
D O I
10.1002/stc.109
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
We discuss the application of a new class of low-cost and high-reliability semi-active devices for the response mitigation of structures subject to earthquakes. These devices, which manipulate stiffness rather than damping, are evaluated by the smart base-isolated benchmark building. The basic motivation, idealization as a stiffness resetting damper or device, development of control logic that ensures the semi-active property, and initial testing and validation results from recently developed prototypes are discussed. The principle idea allows the use of reliable and inexpensive hydraulic or pneumatic technologies, and leads to a decentralized and easy to implement architecture. The results from the benchmark simulations show performance competitive with well-known semi-active techniques. Copyright (c) 2005 John Wiley & Sons, Ltd.
引用
收藏
页码:748 / 757
页数:10
相关论文
共 50 条
  • [31] Radial basis function neural network algorithm for semi-active control of base-isolated structures
    Krishnamoorthy, Agrahara
    Bhat, Shubha
    Bhasari, Dattatreya
    STRUCTURAL CONTROL & HEALTH MONITORING, 2017, 24 (10):
  • [32] INFLUENCE OF HIGH INITIAL ISOLATOR STIFFNESS ON THE SEISMIC RESPONSE OF A BASE-ISOLATED BENCHMARK BUILDING
    Sharma, Ajay
    Jangid, R. S.
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2011, 11 (06) : 1201 - 1228
  • [33] Ground motion pulse-based active control of a linear base-isolated benchmark building
    Agrawal, AK
    Xu, Z
    He, WL
    STRUCTURAL CONTROL & HEALTH MONITORING, 2006, 13 (2-3): : 792 - 808
  • [34] Hierarchical semi-active control of base-isolated structures using a new inverse model of magnetorheological dampers
    Bahar, Arash
    Pozo, Francesc
    Acho, Leonardo
    Rodellar, Jose
    Barbat, Alex H.
    COMPUTERS & STRUCTURES, 2010, 88 (7-8) : 483 - 496
  • [35] Vibration characteristics change of a base-isolated building with semi-active dampers before, during, and after the 2011 Great East Japan earthquake
    Dan, Maki
    Ishizawa, Yuji
    Tanaka, Sho
    Nakahara, Shuchi
    Wakayama, Shizuka
    Kohiyama, Masayuki
    EARTHQUAKES AND STRUCTURES, 2015, 8 (04) : 889 - 913
  • [36] Development of distributed tunable friction pendulum system (DTFPS) for semi-active control of base-isolated buildings
    Yi Zeng
    Peng Pan
    Youming Guo
    Bulletin of Earthquake Engineering, 2021, 19 : 6243 - 6268
  • [37] Seismic reduction of semi-active base-isolated structures based on multi-level fuzzy control
    Zhao D.-H.
    Li Y.-X.
    Li H.-N.
    Qian H.
    Li, Yong-Xing, 1600, Chinese Vibration Engineering Society (35): : 78 - 84
  • [38] Development of distributed tunable friction pendulum system (DTFPS) for semi-active control of base-isolated buildings
    Zeng, Yi
    Pan, Peng
    Guo, Youming
    BULLETIN OF EARTHQUAKE ENGINEERING, 2021, 19 (14) : 6243 - 6268
  • [39] Semi-Active Base Isolation with Harmonically Varying Damping (Performance Improvement and Application to MR Damper)
    Hirohata, Satoshi
    Iba, Daisuke
    Nakamura, Morimasa
    Moriwaki, Ichiro
    DYNAMICS FOR SUSTAINABLE ENGINEERING, 2011, VOL 4, 2011, : 1839 - 1848
  • [40] A semi-active controller tuning and application to base seismically-isolated structures
    Teodorescu, C. -S.
    Diop, S.
    Politopoulos, I.
    Benidir, M.
    2013 EUROPEAN CONTROL CONFERENCE (ECC), 2013, : 3258 - 3263