Application of a high-pressure gas semi-active resettable damper to the benchmark smart base-isolated building

被引:17
|
作者
Leavitt, John [1 ]
Bobrow, James E. [1 ]
Jabbari, Faryar [1 ]
Yang, Jann N. [1 ]
机构
[1] Univ Calif Irvine, Henry Samueli Sch Engn, Irvine, CA 92697 USA
来源
STRUCTURAL CONTROL & HEALTH MONITORING | 2006年 / 13卷 / 2-3期
关键词
resetting stiffness devices; semi-active control;
D O I
10.1002/stc.109
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
We discuss the application of a new class of low-cost and high-reliability semi-active devices for the response mitigation of structures subject to earthquakes. These devices, which manipulate stiffness rather than damping, are evaluated by the smart base-isolated benchmark building. The basic motivation, idealization as a stiffness resetting damper or device, development of control logic that ensures the semi-active property, and initial testing and validation results from recently developed prototypes are discussed. The principle idea allows the use of reliable and inexpensive hydraulic or pneumatic technologies, and leads to a decentralized and easy to implement architecture. The results from the benchmark simulations show performance competitive with well-known semi-active techniques. Copyright (c) 2005 John Wiley & Sons, Ltd.
引用
收藏
页码:748 / 757
页数:10
相关论文
共 50 条
  • [11] Superelastic semi-active damping of a base-isolated structure
    Shook, D. A.
    Roschke, P. N.
    Ozbulut, O. E.
    STRUCTURAL CONTROL & HEALTH MONITORING, 2008, 15 (05): : 746 - 768
  • [12] Seismic performance improvement of base-isolated structures using a semi-active tuned mass damper
    Wang, Liangkun
    Nagarajaiah, Satish
    Shi, Weixing
    Zhou, Ying
    ENGINEERING STRUCTURES, 2022, 271
  • [13] Semi-active control of seismically excited base-isolated building model with friction pendulum systems
    Xu, Zhou
    Agrawal, Anil K.
    STRUCTURAL CONTROL & HEALTH MONITORING, 2008, 15 (05): : 769 - 784
  • [14] Semi-active tuned mass damper building systems: Application
    Chey, Min-Ho
    Chase, J. Geoffrey
    Mander, John B.
    Carr, Athol J.
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2010, 39 (01): : 69 - 89
  • [15] Base-isolated structures with selective controlled semi-active friction dampers
    Ribakov, Y.
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2011, 20 (07): : 757 - 766
  • [16] Seismic analysis and performance of semi-active spring for base-isolated structures
    Jangid, R. S.
    JOURNAL OF LOW FREQUENCY NOISE VIBRATION AND ACTIVE CONTROL, 2025, 44 (01) : 497 - 511
  • [17] Application of the resettable semi-active damper device for macro modelling of confined semi-interlocking masonry walls
    Hemmat, Mehdi
    Totoev, Yuri Z.
    Masia, Mark J.
    INTERNATIONAL JOURNAL OF MASONRY RESEARCH AND INNOVATION, 2021, 6 (02) : 208 - 231
  • [18] Smart system design for a 3D base-isolated benchmark building
    Wang, Yumei
    Dyke, Shirley
    STRUCTURAL CONTROL & HEALTH MONITORING, 2008, 15 (07): : 939 - 957
  • [19] Smart base-isolated benchmark building. Part I: problem definition
    Narasimhan, S.
    Nagarajaiah, S.
    Johnson, E. A.
    Gavin, H. P.
    STRUCTURAL CONTROL & HEALTH MONITORING, 2006, 13 (2-3): : 573 - 588
  • [20] Application of angular-mass dampers to base-isolated benchmark building
    Pradono, Mulyo Harris
    Iemura, Hirokazu
    Igarashi, Akira
    Kalantari, Afshin
    STRUCTURAL CONTROL & HEALTH MONITORING, 2008, 15 (05): : 737 - 745