Ground motion pulse-based active control of a linear base-isolated benchmark building

被引:27
|
作者
Agrawal, AK [1 ]
Xu, Z
He, WL
机构
[1] CUNY City Coll, Dept Civil Engn, New York, NY 10031 USA
[2] WSP Cantor Seinuk, New York, NY 10017 USA
来源
STRUCTURAL CONTROL & HEALTH MONITORING | 2006年 / 13卷 / 2-3期
关键词
base isolation; active control; pulse filter; base-isolated benchmark building model; structural response control;
D O I
10.1002/stc.112
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, the performance of different active controllers, including an active with pulse filter (APF) controller, in which the controller is designed using a ground motion pulse filter recently proposed by the authors, has been investigated for the benchmark base-isolated building model subject to various near-field ground motions. The pulse model utilizes pulse period, pulse damping factor and pulse shape factor from recorded ground motions to represent dominant kinematic characteristics of actual near-field ground motion pulses. Comparison of various active control approaches, such as linear quadratic gaussian (LQG), LQG with Kanai-Tajimi filter, APF and sample controller, demonstrates that the APF controller is capable of reducing base displacement (drift of isolators), superstructure drift and absolute accelerations of all the floors simultaneously while using the same control force level as other controllers. The reduction in all these response quantities is much more significant for the APF controller than other active control strategies. The peak amplitudes of various response quantities of the structure with APF controller are damped much faster than those with the sample controller. Copyright (c) 2005 John Wiley & Sons, Ltd.
引用
收藏
页码:792 / 808
页数:17
相关论文
共 50 条
  • [1] Robust active control of hysteretic base-isolated structures: Application to the benchmark smart base-isolated building
    Pozo, Francesc
    Montserrat, Pere Marc
    Rodellar, Jose
    Acho, Leonardo
    STRUCTURAL CONTROL & HEALTH MONITORING, 2008, 15 (05): : 720 - 736
  • [2] Semi-active and passive control of the phase I linear base-isolated benchmark building model
    Xu, Zhou
    Agrawal, Anil K.
    Yang, Jann N.
    STRUCTURAL CONTROL & HEALTH MONITORING, 2006, 13 (2-3): : 626 - 648
  • [3] Parametric Sensitivity of Ground Motion Pulse Filter for Response Control of Base-Isolated Buildings
    Agrawal, Anil K.
    Xu, Zhou
    JOURNAL OF EARTHQUAKE ENGINEERING, 2009, 13 (04) : 407 - 425
  • [4] Control of Secondary Systems Response in a Base-Isolated Building under Tridirectional Ground Motion
    Kamble, Vishal
    Bharti, Shiv Dayal
    Shrimali, Mahendra Kumar
    Datta, Tushar Kanti
    PRACTICE PERIODICAL ON STRUCTURAL DESIGN AND CONSTRUCTION, 2022, 27 (01)
  • [5] Sequential Ground Motion Effects on the Behavior of a Base-Isolated RCC Building
    Zheng, Zhi
    Pan, Xiaolan
    Bao, Xu
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2017, 2017
  • [6] Semi-active neurocontrol of a base-isolated benchmark structure
    Lee, Heon-Jae
    Yang, Guangqiang
    Jung, Hyung-Jo
    Spencer, Billie F., Jr.
    Lee, In-Won
    STRUCTURAL CONTROL & HEALTH MONITORING, 2006, 13 (2-3): : 682 - 692
  • [7] Influence of the angle of seismic incidence of long-period pulse-like ground motion on an irregular base-isolated building
    Fujii, Kenji
    FRONTIERS IN BUILT ENVIRONMENT, 2022, 8
  • [8] Performance of variable curvature sliding isolators in base-isolated benchmark building
    Sharma, Ajay
    Jangid, R. S.
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2012, 21 (05): : 354 - 373
  • [9] Seismic Response of Base-Isolated Benchmark Building with Variable Sliding Isolators
    Sharma, Ajay
    Jangid, R. S.
    JOURNAL OF EARTHQUAKE ENGINEERING, 2010, 14 (07) : 1063 - 1091
  • [10] Cubic control for phase I smart base-isolated benchmark building with emphasis on nonstructural performance
    Xu, Xin
    Singh, Tarunraj
    Dargush, Gary F.
    STRUCTURAL CONTROL & HEALTH MONITORING, 2006, 13 (2-3): : 758 - 774