INFLUENCE OF HIGH INITIAL ISOLATOR STIFFNESS ON THE SEISMIC RESPONSE OF A BASE-ISOLATED BENCHMARK BUILDING

被引:12
|
作者
Sharma, Ajay [1 ]
Jangid, R. S. [1 ]
机构
[1] Indian Inst Technol, Dept Civil Engn, Bombay 400076, Maharashtra, India
关键词
Base isolation; benchmark building; earthquake; initial isolator stiffness; stiffness ratio; characteristic strength; SEMIACTIVE CONTROL; CONTROL-SYSTEMS; BRIDGES; MOTIONS;
D O I
10.1142/S0219455411004543
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The influence of high initial isolator stiffness on the response of a base-isolated benchmark building is investigated. The base-isolated building is modeled as a three-dimensional linear-elastic structure having three degrees-of-freedom at each floor level. The time-history analysis of this building is carried out by solving the governing equations of motion using Newmark-beta method along with an iterative predictor-corrector approach. The force-deformation behavior of the isolation system is modeled by a bilinear law, which can be effectively used to model all isolation systems in practice. Three near-field earthquakes with bidirectional ground motions are considered. Structural response parameters such as absolute top floor acceleration, base shear, and base displacement are chosen for investigating the effects of high initial isolator stiffness. It was observed that the high initial isolator stiffness of the isolation system excites the higher modes in the base-isolated building and increases the top floor acceleration. Such a phenomenon can be detrimental to the sensitive instruments placed in the isolated structure. On the other hand, both the base displacement and base shear reduce marginally due to increase in the initial isolator stiffness. Further, the influences of high initial isolator stiffness are found to dependent on the period and characteristic strengths of the base isolation system.
引用
收藏
页码:1201 / 1228
页数:28
相关论文
共 50 条
  • [1] Behaviour of base-isolated structures with high initial isolator stiffness
    Sharma, Ajay
    Jangid, R.S.
    World Academy of Science, Engineering and Technology, 2009, 38 : 186 - 191
  • [2] Influence of high austenite stiffness of shape memory alloy on the response of base-isolated benchmark building
    Ghodke, Sharad
    Jangid, R. S.
    STRUCTURAL CONTROL & HEALTH MONITORING, 2017, 24 (02):
  • [3] Seismic Response of Base-Isolated Benchmark Building with Variable Sliding Isolators
    Sharma, Ajay
    Jangid, R. S.
    JOURNAL OF EARTHQUAKE ENGINEERING, 2010, 14 (07) : 1063 - 1091
  • [4] Seismic response of base-isolated buildings: exploring isolator properties
    Domadzra Y.
    Bhandari M.
    Hasan M.
    Asian Journal of Civil Engineering, 2024, 25 (5) : 4197 - 4209
  • [5] Influence of isolator characteristics on the response of base-isolated structures
    Matsagar, VA
    Jangid, RS
    ENGINEERING STRUCTURES, 2004, 26 (12) : 1735 - 1749
  • [6] Comparison of Seismic Response Characteristics Between Non Base-isolated and Base-isolated Building
    Enomoto, Takahisa
    Ninomiya, Masayuki
    Navarro, Manuel
    PROCEEDINGS OF THE 8TH INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS, EURODYN 2011, 2011, : 2797 - 2804
  • [7] Base-isolated building with asymmetries due to the isolator parameters
    Matsagar, VA
    Jangid, RS
    ADVANCES IN STRUCTURAL ENGINEERING, 2005, 8 (06) : 603 - 621
  • [8] SEISMIC RESPONSE OF THE SUPERSTRUCTURE AND ATTACHED EQUIPMENT IN A BASE-ISOLATED BUILDING
    TSAI, HC
    KELLY, JM
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1989, 18 (04): : 551 - 564
  • [9] Seismic performance of a base-isolated demonstration building
    Taniwangsa, W
    EARTHQUAKE SPECTRA, 2002, 18 (04) : 777 - 793
  • [10] Negative stiffness device for seismic protection of smart base isolated benchmark building
    Sun, Tong
    Lai, Zhilu
    Nagarajaiah, Satish
    Li, Hong-Nan
    STRUCTURAL CONTROL & HEALTH MONITORING, 2017, 24 (11):