INFLUENCE OF HIGH INITIAL ISOLATOR STIFFNESS ON THE SEISMIC RESPONSE OF A BASE-ISOLATED BENCHMARK BUILDING

被引:12
|
作者
Sharma, Ajay [1 ]
Jangid, R. S. [1 ]
机构
[1] Indian Inst Technol, Dept Civil Engn, Bombay 400076, Maharashtra, India
关键词
Base isolation; benchmark building; earthquake; initial isolator stiffness; stiffness ratio; characteristic strength; SEMIACTIVE CONTROL; CONTROL-SYSTEMS; BRIDGES; MOTIONS;
D O I
10.1142/S0219455411004543
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The influence of high initial isolator stiffness on the response of a base-isolated benchmark building is investigated. The base-isolated building is modeled as a three-dimensional linear-elastic structure having three degrees-of-freedom at each floor level. The time-history analysis of this building is carried out by solving the governing equations of motion using Newmark-beta method along with an iterative predictor-corrector approach. The force-deformation behavior of the isolation system is modeled by a bilinear law, which can be effectively used to model all isolation systems in practice. Three near-field earthquakes with bidirectional ground motions are considered. Structural response parameters such as absolute top floor acceleration, base shear, and base displacement are chosen for investigating the effects of high initial isolator stiffness. It was observed that the high initial isolator stiffness of the isolation system excites the higher modes in the base-isolated building and increases the top floor acceleration. Such a phenomenon can be detrimental to the sensitive instruments placed in the isolated structure. On the other hand, both the base displacement and base shear reduce marginally due to increase in the initial isolator stiffness. Further, the influences of high initial isolator stiffness are found to dependent on the period and characteristic strengths of the base isolation system.
引用
收藏
页码:1201 / 1228
页数:28
相关论文
共 50 条
  • [21] Response spectrum analysis considering non-classical damping in the base-isolated benchmark building
    Chen, Huating
    Tan, Ping
    Ma, Haitao
    Zhou, Fulin
    STRUCTURAL ENGINEERING AND MECHANICS, 2017, 64 (04) : 473 - 485
  • [22] Performance of variable curvature sliding isolators in base-isolated benchmark building
    Sharma, Ajay
    Jangid, R. S.
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2012, 21 (05): : 354 - 373
  • [23] Experimental Assessment of the Seismic Response of a Base-Isolated Building Through a Hybrid Simulation Technique
    Furinghetti, Marco
    Lanese, Igor
    Pavese, Alberto
    FRONTIERS IN BUILT ENVIRONMENT, 2020, 6
  • [24] Semi-active seismic response control of base-isolated building with MR damper
    Soda, S
    Kusumoto, H
    Chatani, R
    Iwata, N
    Fujitani, H
    Shiozaki, Y
    Hiwatashi, T
    SMART STRUCTURES AND MATERIALS 2003: DAMPING AND ISOLATION, 2003, 5052 : 460 - 467
  • [25] Application of angular-mass dampers to base-isolated benchmark building
    Pradono, Mulyo Harris
    Iemura, Hirokazu
    Igarashi, Akira
    Kalantari, Afshin
    STRUCTURAL CONTROL & HEALTH MONITORING, 2008, 15 (05): : 737 - 745
  • [26] Seismic rehabilitation of a base-isolated building using viscous dampers
    Hart, GC
    Brandow, G
    Johnston, R
    STRUCTURAL DESIGN OF TALL BUILDINGS, 2001, 10 (05): : 335 - 338
  • [27] Experimental seismic performance of a base-isolated building with displacement limiters
    Du, Hongkai
    Wang, Yuandong
    Han, Miao
    Ibarra, Luis F.
    ENGINEERING STRUCTURES, 2021, 244
  • [28] Investigation of atypical seismic response of a base-isolated bridge
    Chaudhary, MTA
    Abé, M
    Fujino, Y
    ENGINEERING STRUCTURES, 2002, 24 (07) : 945 - 953
  • [29] Seismic response of base-isolated liquid storage tanks
    Shrimali, MK
    Jangid, RS
    JOURNAL OF VIBRATION AND CONTROL, 2003, 9 (10) : 1201 - 1218
  • [30] Seismic performance of a building base-isolated by TFP to with a moat wall
    Movahhed, Ataallah Sadeghi
    Zardari, Saeid
    Sadoglu, Erol
    EARTHQUAKES AND STRUCTURES, 2022, 23 (01) : 87 - 100