Reference tissue quantification of DCE-MRI data without a contrast agent calibration

被引:26
|
作者
Walker-Samuel, Simon [1 ]
Leach, Martin O.
Collins, David J.
机构
[1] Inst Canc Res, Canc Res UK Clin Magnet Resonance Res Grp, Sutton SM2 5NG, Surrey, England
[2] Royal Marsden NHS Fdn Trust, Sutton SM2 5NG, Surrey, England
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2007年 / 52卷 / 03期
关键词
D O I
10.1088/0031-9155/52/3/004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The quantification of dynamic contrast- enhanced ( DCE) MRI data conventionally requires a conversion from signal intensity to contrast agent concentration by measuring a change in the tissue longitudinal relaxation rate, R-1. In this paper, it is shown that the use of a spoiled gradient- echo acquisition sequence ( optimized so that signal intensity scales linearly with contrast agent concentration) in conjunction with a reference tissue- derived vascular input function ( VIF), avoids the need for the conversion to Gd- DTPA concentration. This study evaluates how to optimize such sequences and which dynamic time-series parameters are most suitable for this type of analysis. It is shown that signal difference and relative enhancement provide useful alternatives when full contrast agent quantification cannot be achieved, but that pharmacokinetic parameters derived from both contain sources of error ( such as those caused by differences between reference tissue and region of interest proton density and native T-1 values). It is shown in a rectal cancer study that these sources of uncertainty are smaller when using signal difference, compared with relative enhancement ( 15 +/- 4% compared with 33 +/- 4%). Both of these uncertainties are of the order of those associated with the conversion to Gd- DTPA concentration, according to literature estimates.
引用
收藏
页码:589 / 601
页数:13
相关论文
共 50 条
  • [31] Comparison of analytical and numerical analysis of the reference region model for DCE-MRI
    Lee, Joonsang
    Cardenas-Rodriguez, Julio
    Pagel, Mark D.
    Platt, Simon
    Kent, Marc
    Zhao, Quri
    MAGNETIC RESONANCE IMAGING, 2014, 32 (07) : 845 - 853
  • [32] Delay and dispersion correction for simultaneous quantification of perfusion and permeability in the prostate using DCE-MRI with a dual-contrast sequence
    Luedemann, Lutz
    Prochnow, Daniel
    Franiel, Tobias
    Taupitz, Matthias
    Rehbein, Hagen
    Beyersdorff, Dirk
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 14 - +
  • [33] A visual analytics approach to diagnosis of breast DCE-MRI data
    Glasser, Sylvia
    Preim, Uta
    Toennies, Klaus
    Preim, Bernhard
    COMPUTERS & GRAPHICS-UK, 2010, 34 (05): : 602 - 611
  • [34] Combined motion correction and segmentation of DCE-MRI kidney data
    Hodneland, Erlend
    Hanson, Erik
    Lundervold, Arvid
    Modersitzki, Jan
    Munthe-Kaas, Antonella Z.
    ACTA RADIOLOGICA, 2013, 54 (04) : 7 - 8
  • [35] Abdominal DCE-MRI reconstruction with deformable motion correction for liver perfusion quantification
    Johansson, Adam
    Balter, James M.
    Cao, Yue
    MEDICAL PHYSICS, 2018, 45 (10) : 4529 - 4540
  • [36] Boosting in Nonlinear Regression Models with an Application to DCE-MRI Data
    Feilke, M.
    Bischl, B.
    Schmid, V. J.
    Gertheiss, J.
    METHODS OF INFORMATION IN MEDICINE, 2016, 55 (01) : 31 - 41
  • [37] Anti-angiogenic Effects of Bumetanide Revealed by DCE-MRI with a Biodegradable Macromolecular Contrast Agent in a Colon Cancer Model
    Malamas, Anthony S.
    Jin, Erlei
    Zhang, Qi
    Haaga, John
    Lu, Zheng-Rong
    PHARMACEUTICAL RESEARCH, 2015, 32 (09) : 3029 - 3043
  • [38] A reference agent model for DCE MRI can be used to quantify the relative vascular permeability of two MRI contrast agents
    Cardenas-Rodriguez, Julio
    Howison, Christine M.
    Matsunaga, Terry O.
    Pagel, Mark D.
    MAGNETIC RESONANCE IMAGING, 2013, 31 (06) : 900 - 910
  • [39] DCE-Qnet: deep network quantification of dynamic contrast enhanced (DCE) MRI
    Cohen, Ouri
    Kargar, Soudabeh
    Woo, Sungmin
    Vargas, Alberto
    Otazo, Ricardo
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2024, 37 (06): : 1077 - 1090
  • [40] Measurement of Rat Brain Tumor Kinetics Using an Intravascular MR Contrast Agent and DCE-MRI Nested Model Selection
    Chwang, Wilson B.
    Jain, Rajan
    Bagher-Ebadian, Hassan
    Nejad-Davarani, Siamak P.
    Iskander, A. S. M.
    VanSlooten, Ashley
    Schultz, Lonni
    Arbab, Ali S.
    Ewing, James R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 40 (05) : 1223 - 1229