摘要
Hydrogen sulfide is a highly corrosive, harmful, and toxic gas produced under anaerobic conditions within industrial processes or in natural environments, and plays an important role in the sulfur cycle. According to the U.S. Occupational Safety and Health Administration (OSHA), the permissible exposure limit (during 8 hours) is 10 ppm. Concentrations of 20 ppm are the threshold for critical health issues. In workplace environments with human subjects frequently exposed to H2S, e. g., during petroleum extraction and refining, real-time monitoring of exposure levels is mandatory. Sensors based on electrochemical measurement principles, semiconducting metal-oxides, taking advantage of their optical properties, have been described for H2S monitoring. However, extended response times, limited selectivity, and bulkiness of the instrumentation are common disadvantages of the sensing techniques reported to date. Here, we describe for the first time usage of a new generation of compact gas cells, i.e., so-called substrate-integrated hollow waveguides (iHWGs), combined with a compact Fourier transform infrared (FTIR) spectrometer for advanced gas sensing of H2S. The principle of detection is based on the immediate UV-assisted conversion of the rather weak IR-absorber H2S into much more pronounced and distinctively responding SO2. A calibration was established in the range of 10-100 ppm with a limit of detection (LOD) at 3 ppm, which is suitable for occupational health monitoring purposes. The developed sensing scheme provides an analytical response time of less than 60 seconds. Considering the substantial potential for miniaturization using e. g., a dedicated quantum cascade laser (QCL) in lieu of the FTIR spectrometer, the developed sensing approach may be evolved into a hand-held instrument, which may be tailored to a variety of applications ranging from environmental monitoring to workplace safety surveillance, process analysis and clinical diagnostics, e. g., breath analysis.
引用
收藏
页码:198 / 203
页数:6
相关论文
共 50 条
  • [1] Real-time monitoring of ozone in air using substrate-integrated hollow waveguide mid-infrared sensors
    João Flávio da Silveira Petruci
    Paula Regina Fortes
    Vjekoslav Kokoric
    Andreas Wilk
    Ivo Milton Raimundo
    Arnaldo Alves Cardoso
    Boris Mizaikoff
    Scientific Reports, 3
  • [2] Real-time monitoring of ozone in air using substrate-integrated hollow waveguide mid-infrared sensors
    da Silveira Petruci, Joao Flavio
    Fortes, Paula Regina
    Kokoric, Vjekoslav
    Wilk, Andreas
    Raimundo, Ivo Milton, Jr.
    Cardoso, Arnaldo Alves
    Mizaikoff, Boris
    SCIENTIFIC REPORTS, 2013, 3
  • [3] Towards the determination of isoprene in human breath using substrate-integrated hollow waveguide mid-infrared sensors
    Perez-Guaita, David
    Kokoric, Vjekoslav
    Wilk, Andreas
    Garrigues, Salvador
    Mizaikoff, Boris
    JOURNAL OF BREATH RESEARCH, 2014, 8 (02)
  • [4] Optimized design of substrate-integrated hollow waveguides for mid-infrared gas analyzers
    Fortes, Paula Regina
    da Silveira Petruci, Joao Flavio
    Wilk, Andreas
    Cardoso, Arnaldo Alves
    Raimundo, Ivo Milton, Jr.
    Mizaikoff, Boris
    JOURNAL OF OPTICS, 2014, 16 (09)
  • [5] Fiber-Coupled Substrate-Integrated Hollow Waveguides: An Innovative Approach to Mid-infrared Remote Gas Sensors
    Tuetuencue, Erhan
    Kokoric, Vjekoslav
    Wilk, Andreas
    Seichter, Felicia
    Schmid, Michael
    Hunt, William E.
    Manuel, Anastacia M.
    Mirkarimi, Paul
    Alameda, Jennifer B.
    Carter, J. Chance
    Mizaikoff, Boris
    ACS SENSORS, 2017, 2 (09): : 1287 - 1293
  • [6] RobustATR: Substrate-Integrated Hollow Waveguide Coupled Infrared Attenuated Total Reflectance Sensors
    Teuber, Andrea
    Mizaikoff, Boris
    APPLIED SCIENCES-BASEL, 2022, 12 (19):
  • [7] Substrate-Integrated Hollow Waveguides: A New Level of Integration in Mid-Infrared Gas Sensing
    Wilk, Andreas
    Carter, J. Chance
    Chrisp, Michael
    Manuel, Anastacia M.
    Mirkarimi, Paul
    Alameda, Jennifer B.
    Mizaikoff, Boris
    ANALYTICAL CHEMISTRY, 2013, 85 (23) : 11205 - 11210
  • [8] Miniaturizing gas sensors combining mid-infrared interband cascade light emitting diodes with substrate-integrated hollow waveguides
    Hlavatsch, Michael
    Schaefer, Nicolas
    Weih, Robert
    Koeth, Johannes
    Kunsch, Johannes
    Mizaikoff, Boris
    AIP ADVANCES, 2024, 14 (08)
  • [9] Hollow Waveguide-Enhanced Mid-Infrared Sensor for Real-Time Exhaled Methane Detection
    Liu, Lin
    Xiong, Bo
    Yan, Yue
    Li, Jinyi
    Du, Zhenhui
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2016, 28 (15) : 1613 - 1616
  • [10] polyHWG: 3D Printed Substrate-Integrated Hollow Waveguides for Mid-Infrared Gas Sensing
    Stach, Robert
    Haas, Julian
    Tuetuencue, Erhan
    Daboss, Sven
    Kranz, Christine
    Mizaikoff, Boris
    ACS SENSORS, 2017, 2 (11): : 1700 - 1705