Uteroplacental and Fetal 4D Flow MRI in the Pregnant Rhesus Macaque

被引:19
|
作者
Macdonald, Jacob A. [1 ]
Corrado, Philip A. [1 ]
Nguyen, Sydney M. [2 ]
Johnson, Kevin M. [1 ]
Francois, Christopher J. [3 ]
Magness, Ronald R. [4 ]
Shah, Dinesh M. [5 ]
Golos, Thaddeus G. [2 ,6 ]
Wieben, Oliver [1 ,3 ]
机构
[1] Univ Wisconsin, Dept Med Phys, 1530 Med Sci Ctr, Madison, WI 53706 USA
[2] Univ Wisconsin, Wisconsin Natl Primate Ctr, Madison, WI USA
[3] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[4] Univ S Florida, Dept Obstet & Gynecol, Tampa, FL USA
[5] Univ Wisconsin, Dept Obstet & Gynecol, Madison, WI 53706 USA
[6] Univ Wisconsin, Dept Comparat Biosci, 2015 Linden Dr W, Madison, WI 53706 USA
基金
美国国家卫生研究院;
关键词
BLOOD-FLOW; UTERINE ARTERIES; ULTRASOUND; RESISTANCE; PREECLAMPSIA; RESOLUTION; OVARIAN;
D O I
10.1002/jmri.26206
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Pregnancy complications are often associated with poor uteroplacental vascular adaptation and standard diagnostics are unable to reliably quantify flow in all uteroplacental vessels and have poor sensitivity early in gestation. Purpose To investigate the feasibility of using 4D flow MRI to assess total uteroplacental blood flow in pregnant rhesus macaques as a precursor to human studies. Study Type Retrospective feasibility study. Animal Model Fifteen healthy, pregnant rhesus macaques ranging from the 1(st) trimester to 3(rd) trimester of gestation. Field Strength/Sequence Abdominal 4D flow MRI was performed on a 3.0T scanner with a radially undersampled phase contrast (PC) sequence. Reference ferumoxytol-enhanced angiograms were acquired with a 3D ultrashort echo time sequence with a center-out radial trajectory. Assessment Repeatability of flow measurements was assessed with scans performed same-day and on consecutive days in the uterine arteries and ovarian veins. In-flow was compared against out-flow in the uterus, umbilical cord, and fetal heart with a conservation of mass analysis. Conspicuity of uteroplacental vessels was qualitatively compared between PC angiograms derived from 4D flow data and ferumoxytol-enhanced angiograms. Statistical Tests Bland-Altman analysis was used to quantify same-day and consecutive-day repeatability. Results Same-day flow measurements showed an average difference between scans of 13% in both the uterine arteries and ovarian veins, while consecutive-day measurements showed average differences of 22% and 24%, respectively. Comparisons of in-flow and out-flow showed average differences of 15% in the uterus, 8% in fetal heart, and 15% in the umbilical cord. PC angiograms showed similar depiction of main uteroplacental vessels as high-resolution, ferumoxytol-enhanced angiograms. Data Conclusion 4D flow MRI could be used in the rhesus macaque for repeatable flow measurements in the uteroplacental and fetal vasculature, setting the stage for future human studies. Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:534-545.
引用
收藏
页码:534 / 545
页数:12
相关论文
共 50 条
  • [41] A physiologic flow phantom for the evaluation of 4D flow MRI in the left ventricle
    Ikechukwu (Ikay) Okafor
    Christine Garcia
    Alex J Barker
    John Oshinski
    Ajit P Yoganathan
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [42] 4D magnetic resonance flow imaging (4D flow MRI) in neonates Normal values, changes over time and feasibility
    Vejlstrup, A. M.
    Kromann, J.
    Bundgaard, H.
    Iversen, K.
    Vejlstrup, N.
    EUROPEAN HEART JOURNAL, 2018, 39 : 162 - 162
  • [43] Sketch-based Registration of 3D Cine MRI to 4D flow MRI
    Sabokrohiyeh, Samin
    Ang, Kathleen
    Elbaz, Mohammed
    Samavati, Faramarz
    ICBBT 2019: 2019 11TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL TECHNOLOGY, 2019, : 14 - 21
  • [44] Improved respiratory navigator gating for thoracic 4D flow MRI
    van Ooij, Pim
    Semaan, Edouard
    Schnell, Susanne
    Giri, Shivraman
    Stankovic, Zoran
    Carr, James
    Barker, Alex J.
    Markl, Michael
    MAGNETIC RESONANCE IMAGING, 2015, 33 (08) : 992 - 999
  • [45] Clinical Applications of 4D Flow MRI in the Portal Venous System
    Oechtering, Thekla H.
    Roberts, Grant S.
    Panagiotopoulos, Nikolaos
    Wieben, Oliver
    Reeder, Scott B.
    Roldan-Alzate, Alejandro
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2022, 21 (02) : 340 - 353
  • [46] An analysis of reconstruction noise from undersampled 4D flow MRI
    Partin, Lauren
    Schiavazzi, Daniele E.
    Long, Carlos A. Sing
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 84
  • [47] Modeling Bias Error in 4D Flow MRI Velocity Measurements
    Rothenberger, Sean M.
    Zhang, Jiacheng
    Brindise, Melissa C.
    Schnell, Susanne
    Markl, Michael
    Vlachos, Pavlos P.
    Rayz, Vitaliy L.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2022, 41 (07) : 1802 - 1812
  • [48] Cerebral Sinus Hemodynamics in Adults Revealed by 4D Flow MRI
    Dai, Chihang
    Zhao, Pengfei
    Ding, Heyu
    Lv, Han
    Qiu, Xiaoyu
    Tang, Ruowei
    Xu, Ning
    Huang, Yan
    Han, Xu
    Yang, Zhenghan
    Wang, Zhenchang
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 60 (04) : 1706 - 1717
  • [49] Deep variational network for rapid 4D flow MRI reconstruction
    Valery Vishnevskiy
    Jonas Walheim
    Sebastian Kozerke
    Nature Machine Intelligence, 2020, 2 : 228 - 235
  • [50] Advances in machine learning applications for cardiovascular 4D flow MRI
    Peper, Eva S. S.
    van Ooij, Pim
    Jung, Bernd
    Huber, Adrian
    Graeni, Christoph
    Bastiaansen, Jessica A. M.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9