Uteroplacental and Fetal 4D Flow MRI in the Pregnant Rhesus Macaque

被引:19
|
作者
Macdonald, Jacob A. [1 ]
Corrado, Philip A. [1 ]
Nguyen, Sydney M. [2 ]
Johnson, Kevin M. [1 ]
Francois, Christopher J. [3 ]
Magness, Ronald R. [4 ]
Shah, Dinesh M. [5 ]
Golos, Thaddeus G. [2 ,6 ]
Wieben, Oliver [1 ,3 ]
机构
[1] Univ Wisconsin, Dept Med Phys, 1530 Med Sci Ctr, Madison, WI 53706 USA
[2] Univ Wisconsin, Wisconsin Natl Primate Ctr, Madison, WI USA
[3] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[4] Univ S Florida, Dept Obstet & Gynecol, Tampa, FL USA
[5] Univ Wisconsin, Dept Obstet & Gynecol, Madison, WI 53706 USA
[6] Univ Wisconsin, Dept Comparat Biosci, 2015 Linden Dr W, Madison, WI 53706 USA
基金
美国国家卫生研究院;
关键词
BLOOD-FLOW; UTERINE ARTERIES; ULTRASOUND; RESISTANCE; PREECLAMPSIA; RESOLUTION; OVARIAN;
D O I
10.1002/jmri.26206
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Pregnancy complications are often associated with poor uteroplacental vascular adaptation and standard diagnostics are unable to reliably quantify flow in all uteroplacental vessels and have poor sensitivity early in gestation. Purpose To investigate the feasibility of using 4D flow MRI to assess total uteroplacental blood flow in pregnant rhesus macaques as a precursor to human studies. Study Type Retrospective feasibility study. Animal Model Fifteen healthy, pregnant rhesus macaques ranging from the 1(st) trimester to 3(rd) trimester of gestation. Field Strength/Sequence Abdominal 4D flow MRI was performed on a 3.0T scanner with a radially undersampled phase contrast (PC) sequence. Reference ferumoxytol-enhanced angiograms were acquired with a 3D ultrashort echo time sequence with a center-out radial trajectory. Assessment Repeatability of flow measurements was assessed with scans performed same-day and on consecutive days in the uterine arteries and ovarian veins. In-flow was compared against out-flow in the uterus, umbilical cord, and fetal heart with a conservation of mass analysis. Conspicuity of uteroplacental vessels was qualitatively compared between PC angiograms derived from 4D flow data and ferumoxytol-enhanced angiograms. Statistical Tests Bland-Altman analysis was used to quantify same-day and consecutive-day repeatability. Results Same-day flow measurements showed an average difference between scans of 13% in both the uterine arteries and ovarian veins, while consecutive-day measurements showed average differences of 22% and 24%, respectively. Comparisons of in-flow and out-flow showed average differences of 15% in the uterus, 8% in fetal heart, and 15% in the umbilical cord. PC angiograms showed similar depiction of main uteroplacental vessels as high-resolution, ferumoxytol-enhanced angiograms. Data Conclusion 4D flow MRI could be used in the rhesus macaque for repeatable flow measurements in the uteroplacental and fetal vasculature, setting the stage for future human studies. Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:534-545.
引用
收藏
页码:534 / 545
页数:12
相关论文
共 50 条
  • [31] Evaluation of Pulmonary Hypertension Using 4D Flow MRI
    Cerne, John W.
    Pathrose, Ashitha
    Gordon, Daniel Z.
    Sarnari, Roberto
    Veer, Manik
    Blaisdell, Julie
    Allen, Bradley D.
    Avery, Ryan
    Markl, Michael
    Ragin, Ann
    Carr, James C.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 56 (01) : 234 - 245
  • [32] Congenital Heart Disease Assessment With 4D Flow MRI
    Vasanawala, Shreyas S.
    Hanneman, Kate
    Alley, Marcus T.
    Hsiao, Albert
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (04) : 870 - 886
  • [33] Automated hemodynamic assessment for cranial 4D flow MRI
    Roberts, Grant S.
    Hoffman, Carson A.
    Rivera-Rivera, Leonardo A.
    Berman, Sara E.
    Eisenmenger, Laura B.
    Wieben, Oliver
    MAGNETIC RESONANCE IMAGING, 2023, 97 : 46 - 55
  • [34] Fast Interactive Exploration of 4D MRI Flow Data
    Hennemuth, A.
    Friman, O.
    Schumann, C.
    Bock, J.
    Drexl, J.
    Huellebrand, M.
    Markl, M.
    Peitgen, H. -O.
    MEDICAL IMAGING 2011: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2011, 7964
  • [35] 4D flow MRI applications in congenital heart disease
    Judy Rizk
    European Radiology, 2021, 31 : 1160 - 1174
  • [36] Creating Hemodynamic Atlases of Cardiac 4D Flow MRI
    Cibis, Merih
    Bustamante, Mariana
    Eriksson, Jonatan
    Carlhall, Carl-Johan
    Ebbers, Tino
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (05) : 1389 - 1399
  • [37] The Role of Imaging of Flow Patterns by 4D Flow MRI in Aortic Stenosis
    Garcia, Julio
    Barker, Alex J.
    Markl, Michael
    JACC-CARDIOVASCULAR IMAGING, 2019, 12 (02) : 252 - 266
  • [38] Turning Up the Flow: Cardiovascular 4D Flow MRI during Exercise
    Markl, Michael
    Lee, Jeesoo
    RADIOLOGY-CARDIOTHORACIC IMAGING, 2020, 2 (03):
  • [39] Aortocaval Fistula at 4D Flow MRI: Visualization and Quantification of Vascular Flow
    Lebenatus, Annett
    Ravesh, Mona Salehi
    RADIOLOGY, 2018, 289 (03) : 617 - 617
  • [40] Optimizing encoding strategies for 4D Flow MRI of mean and turbulent flow
    Dirix, Pietro
    Buoso, Stefano
    Kozerke, Sebastian
    SCIENTIFIC REPORTS, 2024, 14 (01):