Uteroplacental and Fetal 4D Flow MRI in the Pregnant Rhesus Macaque

被引:19
|
作者
Macdonald, Jacob A. [1 ]
Corrado, Philip A. [1 ]
Nguyen, Sydney M. [2 ]
Johnson, Kevin M. [1 ]
Francois, Christopher J. [3 ]
Magness, Ronald R. [4 ]
Shah, Dinesh M. [5 ]
Golos, Thaddeus G. [2 ,6 ]
Wieben, Oliver [1 ,3 ]
机构
[1] Univ Wisconsin, Dept Med Phys, 1530 Med Sci Ctr, Madison, WI 53706 USA
[2] Univ Wisconsin, Wisconsin Natl Primate Ctr, Madison, WI USA
[3] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
[4] Univ S Florida, Dept Obstet & Gynecol, Tampa, FL USA
[5] Univ Wisconsin, Dept Obstet & Gynecol, Madison, WI 53706 USA
[6] Univ Wisconsin, Dept Comparat Biosci, 2015 Linden Dr W, Madison, WI 53706 USA
基金
美国国家卫生研究院;
关键词
BLOOD-FLOW; UTERINE ARTERIES; ULTRASOUND; RESISTANCE; PREECLAMPSIA; RESOLUTION; OVARIAN;
D O I
10.1002/jmri.26206
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Pregnancy complications are often associated with poor uteroplacental vascular adaptation and standard diagnostics are unable to reliably quantify flow in all uteroplacental vessels and have poor sensitivity early in gestation. Purpose To investigate the feasibility of using 4D flow MRI to assess total uteroplacental blood flow in pregnant rhesus macaques as a precursor to human studies. Study Type Retrospective feasibility study. Animal Model Fifteen healthy, pregnant rhesus macaques ranging from the 1(st) trimester to 3(rd) trimester of gestation. Field Strength/Sequence Abdominal 4D flow MRI was performed on a 3.0T scanner with a radially undersampled phase contrast (PC) sequence. Reference ferumoxytol-enhanced angiograms were acquired with a 3D ultrashort echo time sequence with a center-out radial trajectory. Assessment Repeatability of flow measurements was assessed with scans performed same-day and on consecutive days in the uterine arteries and ovarian veins. In-flow was compared against out-flow in the uterus, umbilical cord, and fetal heart with a conservation of mass analysis. Conspicuity of uteroplacental vessels was qualitatively compared between PC angiograms derived from 4D flow data and ferumoxytol-enhanced angiograms. Statistical Tests Bland-Altman analysis was used to quantify same-day and consecutive-day repeatability. Results Same-day flow measurements showed an average difference between scans of 13% in both the uterine arteries and ovarian veins, while consecutive-day measurements showed average differences of 22% and 24%, respectively. Comparisons of in-flow and out-flow showed average differences of 15% in the uterus, 8% in fetal heart, and 15% in the umbilical cord. PC angiograms showed similar depiction of main uteroplacental vessels as high-resolution, ferumoxytol-enhanced angiograms. Data Conclusion 4D flow MRI could be used in the rhesus macaque for repeatable flow measurements in the uteroplacental and fetal vasculature, setting the stage for future human studies. Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:534-545.
引用
收藏
页码:534 / 545
页数:12
相关论文
共 50 条
  • [21] Author Correction: Fetal whole heart blood flow imaging using 4D cine MRI
    Thomas A. Roberts
    Joshua F. P. van Amerom
    Alena Uus
    David F. A. Lloyd
    Milou P. M. van Poppel
    Anthony N. Price
    Jacques-Donald Tournier
    Chloe A. Mohanadass
    Laurence H. Jackson
    Shaihan J. Malik
    Kuberan Pushparajah
    Mary A. Rutherford
    Reza Razavi
    Maria Deprez
    Joseph V. Hajnal
    Nature Communications, 11
  • [22] Comparison of turbulent flow measurement schemes for 4D flow MRI
    Ha, Hoijn
    Park, Hanwook
    JOURNAL OF VISUALIZATION, 2019, 22 (03) : 541 - 553
  • [23] Comparison of turbulent flow measurement schemes for 4D flow MRI
    Hoijn Ha
    Hanwook Park
    Journal of Visualization, 2019, 22 : 541 - 553
  • [24] Mpox Virus Vertical Transmission and Fetal Demise in a Pregnant Rhesus Macaque Model.
    Mitzey, Ann M.
    Bhattacharya, Saswati
    Krabbe, Nick P.
    Razo, Elaina R.
    Weiler, Andrea M.
    Bekiares, Nell
    Kamholz, Amy
    Daggett, Greg
    Simmons, Heather
    Basu, Puja
    Hayes, Jennifer M.
    Capuano, Saverio
    O'Connor, David H.
    Friedrich, Thomas C.
    Golos, Thaddeus G.
    Mohr, Emma L.
    REPRODUCTIVE SCIENCES, 2024, 31 : 169A - 170A
  • [25] Stochastic 4D Flow Vector-Field Signatures: A New Approach for Comprehensive 4D Flow MRI Quantification
    Elbaz, Mohammed S. M.
    Malaisrie, Chris
    McCarthy, Patrick
    Markl, Michael
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2021, PT V, 2021, 12905 : 215 - 224
  • [26] MPOX VIRUS (MPXV) VERTICAL TRANSMISSION AND FETAL DEMISE IN A PREGNANT RHESUS MACAQUE MODEL
    Krabbe, Nicholas
    Mitzey, Ann
    Bhattacharya, Saswati
    Razo, Elaina
    Zeng, Xiankun
    Bekiares, Nell
    Moy, Amy
    Kamholz, Amy
    Karl, Julie
    Daggett, Gregory
    Capuano, Saverio
    Simmons, Heather
    Basu, Puja
    Weiler, Andrea M.
    Vansleet, Grace
    O'Connor, David H.
    Friedrich, Thomas
    Golos, Thaddeus
    Mohr, Emma
    PLACENTA, 2024, 154 : E39 - E40
  • [27] Evaluation of Circulation, Γ, as a quantifying metric in 4D flow MRI
    Aaron T Hess
    Malenka M Bissell
    Steffan J Glaze
    Alex Pitcher
    Saul Myerson
    Stefan Neubauer
    Matthew D Robson
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [28] Characterization of cerebral aneurysms using 4D FLOW MRI
    Susanne Schnell
    Sameer A Ansari
    Parmede Vakil
    Michael Hurley
    James Carr
    Hunt Batjer
    Bernard R Bendok
    Timothy J Carroll
    Michael Markl
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [29] 4D flow MRI applications in congenital heart disease
    Rizk, Judy
    EUROPEAN RADIOLOGY, 2021, 31 (02) : 1160 - 1174
  • [30] 4D flow MRI hemodynamic biomarkers for cerebrovascular diseases
    Wahlin, Anders
    Eklund, Anders
    Malm, Jan
    JOURNAL OF INTERNAL MEDICINE, 2022, 291 (02) : 115 - 127