A method to derive appropriate exposure parameters from target exposure index and patient thickness in pediatric digital radiography

被引:11
|
作者
Zhang, Menglong [1 ]
Liu, Kai [1 ]
Niu, Xuecai [2 ]
Liu, Xinli [2 ]
机构
[1] Shandong Med Imaging Res Inst, Dept Radiog, Jinan 250021, Shangdong, Peoples R China
[2] Fourth Hosp Jinan, Dept Radiat Oncol, Jinan, Shandong, Peoples R China
关键词
Radiation dose; Pediatrics; Digital radiography; Exposure index; Radiation protection; COMPUTED RADIOGRAPHY; IMAGE QUALITY; X-RAY; OPTIMIZATION; CHILDREN; CHEST;
D O I
10.1007/s00247-012-2555-3
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Little information exists concerning appropriate exposure and measuring overall patient dose in pediatric digital radiography. To establish a convenient method of appropriate exposure from target exposure index (EI) and thickness in pediatric digital radiography and estimate patient entrance-surface dose (ESD) and dose-area product (DAP) associated with chest, abdomen and pelvis radiography. A formula was deduced to calculate appropriate mAs changed with children's weight and height. EI was used to control image quality. With this formula, dose-optimized procedures were carried out. Data were collected from 180 pediatric examinations, including chest, abdomen and pelvis anterior-posterior (AP) projections. The children were divided into the following age bands: newborns (0-28 days), infants (28 days-2 years) and older children (2-7 years). In each age band, ten children were exposed with the calculated appropriate mAs and EI values were kept steady in appropriate range (referred as target group) and ten children were exposed to the factors routinely used in practice (referred to as the routine group). DAP to children was measured with a DAP meter, and ESD was calculated using measured DAP and data from the National Radiological Protection Board. Data were compared between groups. ESD ranges in the target group were 32-202 mu Gy (chest AP), 57-333 mu Gy (abdomen AP) and 52-372 mu Gy (pelvis AP). For every radiographic procedure, chi-square Student's t tests showed a significant difference in average ESD and DAP between the two groups (P < 0.005). Most ESD values from the routine group were two times higher than those from the target group. The study established a convenient method to set appropriate exposure parameters (mAs) to reach a target EI using the child's weight and height in pediatric radiography. By this method, ESD and DAP can be significantly reduced in children.
引用
收藏
页码:568 / 574
页数:7
相关论文
共 50 条
  • [31] Digital Tomosynthesis for PNS Evaluation: Comparisons of Patient Exposure and Image Quality with Plain Radiography
    Yoo, Jin Young
    Chung, Myung Jin
    Choi, Boram
    Jung, Hye Na
    Koo, Ji Hyun
    Bae, Young A.
    Jeon, Kyeongman
    Byun, Hong Sik
    Lee, Kyung Soo
    KOREAN JOURNAL OF RADIOLOGY, 2012, 13 (02) : 136 - 143
  • [32] DIGITAL CHEST RADIOGRAPHY WITH A LARGE IMAGE INTENSIFIER - EVALUATION OF DIAGNOSTIC PERFORMANCE AND PATIENT EXPOSURE
    MANSSON, LG
    KHEDDACHE, S
    SCHLOSSMAN, D
    BORJESSON, J
    HAKANSSON, E
    MATTSSON, S
    TYLEN, U
    ACTA RADIOLOGICA, 1989, 30 (04) : 337 - 342
  • [33] Implementation of Flag Criteria to Establish Target Exposure Indices and Identify Practice Variation in Digital Radiography
    Chaudhary, P.
    Hulme, K.
    Li, X.
    MEDICAL PHYSICS, 2020, 47 (06) : E321 - E321
  • [34] Survey of patient exposure from general radiography and mammography in Japan in 2014
    Asada, Y.
    Suzuki, S.
    Minami, K.
    Shirakawa, S.
    Kobayashi, M.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2016, 36 (02) : N8 - N18
  • [35] Evaluation of entrance Surface air kerma from exposure index in computed radiography
    Costa, A. M.
    Pelegrino, M. S.
    RADIATION PHYSICS AND CHEMISTRY, 2014, 104 : 198 - 200
  • [36] Investigation of Relationship Between Different Body Parameters and Exposure Factor (mAs) in Digital Chest Radiography
    Lin, J. R.
    Tsai, R. M.
    Huang, S. L.
    Chou, M. C.
    MEDICAL PHYSICS, 2019, 46 (06) : E271 - E271
  • [37] FEASIBILITY OF DISPLAYED EXPOSURE INDEX IN IEC STANDARD FRAMEWORK AS A DOSE OPTIMISATION TOOL FOR DIGITAL RADIOGRAPHY SYSTEMS
    Park, Hyemin
    Yoon, Yongsu
    Tanaka, Nobukazu
    Kim, Jungsu
    Kim, Jungmin
    Morishita, Junji
    RADIATION PROTECTION DOSIMETRY, 2020, 189 (03) : 384 - 394
  • [38] Exposure parameters in sens-a-ray direct digital radiography and their effects on diagnostic accuracy of carious lesions
    Bjön Svenson
    Xie-Qi Shi
    Harry Stamatakis
    Ulf Welander
    Björn Söderfeldt
    Gunilla Tronje
    Kazunori Yoshiura
    John Kristoffersen
    Charlotte Strömberg
    Oral Radiology, 1997, 13 (2) : 83 - 91
  • [39] Evaluation of the different exposure parameters for the accurate diagnosis of peri-implantitis severity in digital panoramic radiography
    Sadik, Elif
    Gokmenoglu, Ceren
    Altun, Gokcen
    Kara, Cankat
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2023, 28 (01): : E16 - E24
  • [40] Using Exposure Index to Develop Thickness-Based Technique Chart for Cross-Table Lateral Hip Radiography
    Topbas, C.
    Fong, G.
    Singh, V.
    Hulme, K.
    Li, X.
    MEDICAL PHYSICS, 2020, 47 (06) : E402 - E403