A method to derive appropriate exposure parameters from target exposure index and patient thickness in pediatric digital radiography
被引:11
|
作者:
Zhang, Menglong
论文数: 0引用数: 0
h-index: 0
机构:
Shandong Med Imaging Res Inst, Dept Radiog, Jinan 250021, Shangdong, Peoples R ChinaShandong Med Imaging Res Inst, Dept Radiog, Jinan 250021, Shangdong, Peoples R China
Zhang, Menglong
[1
]
Liu, Kai
论文数: 0引用数: 0
h-index: 0
机构:
Shandong Med Imaging Res Inst, Dept Radiog, Jinan 250021, Shangdong, Peoples R ChinaShandong Med Imaging Res Inst, Dept Radiog, Jinan 250021, Shangdong, Peoples R China
Liu, Kai
[1
]
Niu, Xuecai
论文数: 0引用数: 0
h-index: 0
机构:
Fourth Hosp Jinan, Dept Radiat Oncol, Jinan, Shandong, Peoples R ChinaShandong Med Imaging Res Inst, Dept Radiog, Jinan 250021, Shangdong, Peoples R China
Niu, Xuecai
[2
]
Liu, Xinli
论文数: 0引用数: 0
h-index: 0
机构:
Fourth Hosp Jinan, Dept Radiat Oncol, Jinan, Shandong, Peoples R ChinaShandong Med Imaging Res Inst, Dept Radiog, Jinan 250021, Shangdong, Peoples R China
Liu, Xinli
[2
]
机构:
[1] Shandong Med Imaging Res Inst, Dept Radiog, Jinan 250021, Shangdong, Peoples R China
[2] Fourth Hosp Jinan, Dept Radiat Oncol, Jinan, Shandong, Peoples R China
Little information exists concerning appropriate exposure and measuring overall patient dose in pediatric digital radiography. To establish a convenient method of appropriate exposure from target exposure index (EI) and thickness in pediatric digital radiography and estimate patient entrance-surface dose (ESD) and dose-area product (DAP) associated with chest, abdomen and pelvis radiography. A formula was deduced to calculate appropriate mAs changed with children's weight and height. EI was used to control image quality. With this formula, dose-optimized procedures were carried out. Data were collected from 180 pediatric examinations, including chest, abdomen and pelvis anterior-posterior (AP) projections. The children were divided into the following age bands: newborns (0-28 days), infants (28 days-2 years) and older children (2-7 years). In each age band, ten children were exposed with the calculated appropriate mAs and EI values were kept steady in appropriate range (referred as target group) and ten children were exposed to the factors routinely used in practice (referred to as the routine group). DAP to children was measured with a DAP meter, and ESD was calculated using measured DAP and data from the National Radiological Protection Board. Data were compared between groups. ESD ranges in the target group were 32-202 mu Gy (chest AP), 57-333 mu Gy (abdomen AP) and 52-372 mu Gy (pelvis AP). For every radiographic procedure, chi-square Student's t tests showed a significant difference in average ESD and DAP between the two groups (P < 0.005). Most ESD values from the routine group were two times higher than those from the target group. The study established a convenient method to set appropriate exposure parameters (mAs) to reach a target EI using the child's weight and height in pediatric radiography. By this method, ESD and DAP can be significantly reduced in children.
机构:
Bundang Jesaeng Gen Hosp, Dept Radiol, Songnam 463774, South KoreaSungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiol, Seoul 135710, South Korea
Yoo, Jin Young
Chung, Myung Jin
论文数: 0引用数: 0
h-index: 0
机构:
Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiol, Seoul 135710, South KoreaSungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiol, Seoul 135710, South Korea
Chung, Myung Jin
Choi, Boram
论文数: 0引用数: 0
h-index: 0
机构:
Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiol, Seoul 135710, South KoreaSungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiol, Seoul 135710, South Korea
Choi, Boram
Jung, Hye Na
论文数: 0引用数: 0
h-index: 0
机构:
Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiol, Seoul 135710, South KoreaSungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiol, Seoul 135710, South Korea
Jung, Hye Na
Koo, Ji Hyun
论文数: 0引用数: 0
h-index: 0
机构:
Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiol, Seoul 135710, South KoreaSungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiol, Seoul 135710, South Korea
Koo, Ji Hyun
Bae, Young A.
论文数: 0引用数: 0
h-index: 0
机构:
Bundang Jesaeng Gen Hosp, Dept Radiol, Songnam 463774, South KoreaSungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiol, Seoul 135710, South Korea
Bae, Young A.
Jeon, Kyeongman
论文数: 0引用数: 0
h-index: 0
机构:
Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Div Pulmonol,Dept Internal Med, Seoul 135710, South KoreaSungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiol, Seoul 135710, South Korea
Jeon, Kyeongman
Byun, Hong Sik
论文数: 0引用数: 0
h-index: 0
机构:
Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiol, Seoul 135710, South KoreaSungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiol, Seoul 135710, South Korea
Byun, Hong Sik
Lee, Kyung Soo
论文数: 0引用数: 0
h-index: 0
机构:
Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiol, Seoul 135710, South KoreaSungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiol, Seoul 135710, South Korea
机构:
Univ Sao Paulo, Fac Filosofia Ciencias & Letras Ribeirao Preto, Dept Fis, BR-14040901 Ribeirao Preto, SP, BrazilUniv Sao Paulo, Fac Filosofia Ciencias & Letras Ribeirao Preto, Dept Fis, BR-14040901 Ribeirao Preto, SP, Brazil
Costa, A. M.
Pelegrino, M. S.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sao Paulo, Fac Filosofia Ciencias & Letras Ribeirao Preto, Dept Fis, BR-14040901 Ribeirao Preto, SP, BrazilUniv Sao Paulo, Fac Filosofia Ciencias & Letras Ribeirao Preto, Dept Fis, BR-14040901 Ribeirao Preto, SP, Brazil