A method to derive appropriate exposure parameters from target exposure index and patient thickness in pediatric digital radiography

被引:11
|
作者
Zhang, Menglong [1 ]
Liu, Kai [1 ]
Niu, Xuecai [2 ]
Liu, Xinli [2 ]
机构
[1] Shandong Med Imaging Res Inst, Dept Radiog, Jinan 250021, Shangdong, Peoples R China
[2] Fourth Hosp Jinan, Dept Radiat Oncol, Jinan, Shandong, Peoples R China
关键词
Radiation dose; Pediatrics; Digital radiography; Exposure index; Radiation protection; COMPUTED RADIOGRAPHY; IMAGE QUALITY; X-RAY; OPTIMIZATION; CHILDREN; CHEST;
D O I
10.1007/s00247-012-2555-3
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Little information exists concerning appropriate exposure and measuring overall patient dose in pediatric digital radiography. To establish a convenient method of appropriate exposure from target exposure index (EI) and thickness in pediatric digital radiography and estimate patient entrance-surface dose (ESD) and dose-area product (DAP) associated with chest, abdomen and pelvis radiography. A formula was deduced to calculate appropriate mAs changed with children's weight and height. EI was used to control image quality. With this formula, dose-optimized procedures were carried out. Data were collected from 180 pediatric examinations, including chest, abdomen and pelvis anterior-posterior (AP) projections. The children were divided into the following age bands: newborns (0-28 days), infants (28 days-2 years) and older children (2-7 years). In each age band, ten children were exposed with the calculated appropriate mAs and EI values were kept steady in appropriate range (referred as target group) and ten children were exposed to the factors routinely used in practice (referred to as the routine group). DAP to children was measured with a DAP meter, and ESD was calculated using measured DAP and data from the National Radiological Protection Board. Data were compared between groups. ESD ranges in the target group were 32-202 mu Gy (chest AP), 57-333 mu Gy (abdomen AP) and 52-372 mu Gy (pelvis AP). For every radiographic procedure, chi-square Student's t tests showed a significant difference in average ESD and DAP between the two groups (P < 0.005). Most ESD values from the routine group were two times higher than those from the target group. The study established a convenient method to set appropriate exposure parameters (mAs) to reach a target EI using the child's weight and height in pediatric radiography. By this method, ESD and DAP can be significantly reduced in children.
引用
收藏
页码:568 / 574
页数:7
相关论文
共 50 条
  • [21] Subjective image quality in digital panoramic radiography in relation to patient exposure
    Scheifele, C
    Hadjizadeh, H
    Thole, U
    Wree, A
    Hopfenmüller, W
    CARS 2001: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2001, 1230 : 1183 - 1183
  • [22] DIGITAL RADIOGRAPHY VERSUS CONVENTIONAL RADIOGRAPHY FOR THE DETECTION OF A SKULL FRACTURE UNDER VARYING EXPOSURE PARAMETERS
    LANGEN, HJ
    KLEIN, HM
    WEIN, B
    SCHIWYBOCHAT, KH
    STARGARDT, A
    GUNTHER, RW
    INVESTIGATIVE RADIOLOGY, 1993, 28 (03) : 231 - 234
  • [23] Feasibility of Anatomy-Specific Exposure Index in Clinical Digital Radiography Images
    Long, Z.
    Littrell, L.
    Schueler, B.
    MEDICAL PHYSICS, 2020, 47 (06) : E536 - E536
  • [24] A Landmark Detection Approach Applied to Robust Estimation of the Exposure Index in Digital Radiography
    Irrera, P.
    Bloch, I.
    Delplanque, M.
    IRBM, 2017, 38 (01) : 42 - 55
  • [25] Paediatric entrance doses from exposure index in computed radiography
    Vano, E.
    Martinez, D.
    Fernandez, J. M.
    Ordiales, J. M.
    Prieto, C.
    Floriano, A.
    Ten, J. I.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (12): : 3365 - 3380
  • [26] OPTIMIZATION OF FILTERING AND EXPOSURE PARAMETERS IN HAND-OPERATED DIGITAL LUMINESCENCE RADIOGRAPHY
    GROTE, R
    NAST, J
    ROSENTHAL, H
    CALLEJA, R
    VONFALKENHAUSEN, U
    RIEDER, P
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1992, 156 (06): : 564 - 569
  • [27] Patient exposure from TMJ radiography with a panoramic unit.
    Rödig, T
    Visser, H
    Hermann, KP
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 286 - 286
  • [28] A Landmark-Based Approach for Robust Estimation of Exposure Index Values in Digital Radiography
    Irrera, Paolo
    Bloch, Isabelle
    Delplanque, Maurice
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2015, PT II, 2015, 9350 : 627 - 634
  • [29] Feasibility of new patient dose management tool in digital radiography: Using clinical exposure index data of mobile chest radiography in a large university hospital
    Park, Hyemin
    Kim, Jungsu
    Kang, Eun-Ju
    Kim, Yeji
    Jo, Hyejin
    Heo, Jin-Haeng
    Yang, Wonseok
    Yoon, Yongsu
    HELIYON, 2023, 9 (10)
  • [30] Proper Management of the Clinical Exposure Index Based on Body Thickness Using Dose Optimization Tools in Digital Chest Radiography: A Phantom Study
    Yoon, Yongsu
    Park, Hyemin
    Kim, Jungmin
    Kim, Jungsu
    Roh, Younghoon
    Tanaka, Nobukazu
    Morishita, Junji
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (10)