Impact of iterative reconstruction on image quality and radiation dose in multidetector CT of large body size adults

被引:98
|
作者
Desai, Gaurav S. [2 ]
Uppot, Raul N. [2 ]
Yu, Elaine W. [3 ]
Kambadakone, Avinash R. [2 ]
Sahani, Dushyant V. [1 ,2 ]
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Div Abdominal Imaging & Intervent,Dept Radiol, Boston, MA 02114 USA
[2] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Abdominal Imaging & Intervent, Boston, MA 02114 USA
[3] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Endocrine Unit, Boston, MA 02114 USA
关键词
Iterative reconstruction; Computed tomography; Image quality; Radiation dose; Obesity; TUBE CURRENT MODULATION; ABDOMINAL CT; COMPUTED-TOMOGRAPHY; PATIENT SIZE; REDUCTION; EXPOSURE; OBESITY; ALGORITHM; MDCT; OPTIMIZATION;
D O I
10.1007/s00330-012-2424-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare image quality and radiation dose using Adaptive Statistical Iterative Reconstruction (ASiR) and Filtered Back Projection (FBP) in patients weighing a parts per thousand yen91 kg. In this Institution Review Board-approved retrospective study, single-phase contrast-enhanced abdominopelvic CT examinations of 100 adults weighing a parts per thousand yen91 kg (mean body weight: 107.6 +/- 17.4 kg range: 91-181.9 kg) with (1) ASiR and (2) FBP were reviewed by two readers in a blinded fashion for subjective measures of image quality (using a subjective standardized numerical scale and objective noise) and for radiation exposure. Imaging parameters and radiation dose results of the two techniques were compared within weight and BMI sub-categories. All examinations were found to be of adequate quality. Both subjective (mean = 1.4 +/- 0.5 vs. 1.6 +/- 0.6, P < 0.05) and objective noise (13.0 +/- 3.2 vs.19.5 +/- 5.7, P < 0.0001) were lower with ASiR. Average radiation dose reduction of 31.5 % was achieved using ASiR (mean CTDIvol. ASiR: 13.5 +/- 7.3 mGy; FBP: 19.7 +/- 9.0 mGy, P < 0.0001). Other measures of image quality were comparable between the two techniques. Trends for all parameters were similar in patients across weight and BMI sub-categories. In obese individuals, abdominal CT images reconstructed using ASiR provide diagnostic images with reduced image noise at lower radiation dose. aEuro cent CT images in obese adults are noisy, even with high radiation dose. aEuro cent Newer iterative reconstruction techniques have theoretical advantages in obese patients. aEuro cent Adaptive statistical iterative reconstruction should reduce image noise and radiation dose. aEuro cent This has been proven in abdominopelvic CT images of obese patients.
引用
收藏
页码:1631 / 1640
页数:10
相关论文
共 50 条
  • [41] Adaptive statistical iterative reconstruction use for radiation dose reduction in pediatric lower-extremity CT: impact on diagnostic image quality
    Amisha Shah
    Mitchell Rees
    Erica Kar
    Kimberly Bolton
    Vincent Lee
    Ashok Panigrahy
    Skeletal Radiology, 2018, 47 : 785 - 793
  • [42] Image quality guided iterative reconstruction for low-dose CT based on CT image statistics
    Duan, Jiayu
    Mou, Xuanqin
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (18):
  • [43] Dose reduction in oncological staging multidetector CT: effect of iterative reconstruction
    Karpitschka, M.
    Augart, D.
    Becker, H-C
    Reiser, M.
    Graser, A.
    BRITISH JOURNAL OF RADIOLOGY, 2013, 86 (1021):
  • [44] Radiation dose and image quality in pediatric chest CT: effects of iterative reconstruction in normal weight and overweight children
    Haesung Yoon
    Myung-Joon Kim
    Choon-Sik Yoon
    Jiin Choi
    Hyun Joo Shin
    Hyun Gi Kim
    Mi-Jung Lee
    Pediatric Radiology, 2015, 45 : 337 - 344
  • [45] Radiation dose reduction and image quality in pediatric abdominal CT with kVp and mAs modulation and an iterative reconstruction technique
    Kim, Jun-Hwee
    Kim, Myung-Joon
    Kim, Ha Yan
    Lee, Mi-Jung
    CLINICAL IMAGING, 2014, 38 (05) : 710 - 714
  • [46] Evaluation of image quality and radiation dose by adaptive statistical iterative reconstruction technique level for chest CT examination
    Hong, Sun Suk
    Lee, Jong-Woong
    Seo, Jeong Beom
    Jung, Jae-Eun
    Choi, Jiwon
    Kweon, Dae Cheol
    RADIATION PROTECTION DOSIMETRY, 2013, 157 (02) : 163 - 171
  • [47] Performance of Iterative Reconstruction and Automated Tube Voltage Selection on the Image Quality and Radiation Dose in Abdominal CT Scans
    Desai, Gaurav S.
    Orrego, Jorge M. Fuentes
    Kambadakone, Avinash R.
    Sahani, Dushyant V.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (06) : 897 - 903
  • [48] Improved image quality and low radiation dose with hybrid iterative reconstruction with 80 kV CT pulmonary angiography
    Laqmani, Azien
    Regier, Marc
    Veldhoen, Simon
    Backhaus, Alexandra
    Wassenberg, Felicia
    Sehner, Susanne
    Groth, Michael
    Nagel, Hans-Dieter
    Adam, Gerhard
    Henes, Frank O.
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (10) : 1962 - 1969
  • [49] Evaluation of an Iterative model-based reconstruction of pediatric abdominal CT with regard to image quality and radiation dose
    Aurumskjold, Marie-Louise
    Soderberg, Marcus
    Stalhammar, Fredrik
    von Steyern, Kristina Vult
    Tingberg, Anders
    Ydstrom, Kristina
    ACTA RADIOLOGICA, 2018, 59 (06) : 740 - 747
  • [50] Six iterative reconstruction algorithms in brain CT: a phantom study on image quality at different radiation dose levels
    Love, A.
    Olsson, M-L
    Siemund, R.
    Stalhammar, F.
    Bjorkman-Burtscher, I. M.
    Soderberg, M.
    BRITISH JOURNAL OF RADIOLOGY, 2013, 86 (1031):