Impact of iterative reconstruction on image quality and radiation dose in multidetector CT of large body size adults

被引:98
|
作者
Desai, Gaurav S. [2 ]
Uppot, Raul N. [2 ]
Yu, Elaine W. [3 ]
Kambadakone, Avinash R. [2 ]
Sahani, Dushyant V. [1 ,2 ]
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Div Abdominal Imaging & Intervent,Dept Radiol, Boston, MA 02114 USA
[2] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Abdominal Imaging & Intervent, Boston, MA 02114 USA
[3] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Endocrine Unit, Boston, MA 02114 USA
关键词
Iterative reconstruction; Computed tomography; Image quality; Radiation dose; Obesity; TUBE CURRENT MODULATION; ABDOMINAL CT; COMPUTED-TOMOGRAPHY; PATIENT SIZE; REDUCTION; EXPOSURE; OBESITY; ALGORITHM; MDCT; OPTIMIZATION;
D O I
10.1007/s00330-012-2424-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare image quality and radiation dose using Adaptive Statistical Iterative Reconstruction (ASiR) and Filtered Back Projection (FBP) in patients weighing a parts per thousand yen91 kg. In this Institution Review Board-approved retrospective study, single-phase contrast-enhanced abdominopelvic CT examinations of 100 adults weighing a parts per thousand yen91 kg (mean body weight: 107.6 +/- 17.4 kg range: 91-181.9 kg) with (1) ASiR and (2) FBP were reviewed by two readers in a blinded fashion for subjective measures of image quality (using a subjective standardized numerical scale and objective noise) and for radiation exposure. Imaging parameters and radiation dose results of the two techniques were compared within weight and BMI sub-categories. All examinations were found to be of adequate quality. Both subjective (mean = 1.4 +/- 0.5 vs. 1.6 +/- 0.6, P < 0.05) and objective noise (13.0 +/- 3.2 vs.19.5 +/- 5.7, P < 0.0001) were lower with ASiR. Average radiation dose reduction of 31.5 % was achieved using ASiR (mean CTDIvol. ASiR: 13.5 +/- 7.3 mGy; FBP: 19.7 +/- 9.0 mGy, P < 0.0001). Other measures of image quality were comparable between the two techniques. Trends for all parameters were similar in patients across weight and BMI sub-categories. In obese individuals, abdominal CT images reconstructed using ASiR provide diagnostic images with reduced image noise at lower radiation dose. aEuro cent CT images in obese adults are noisy, even with high radiation dose. aEuro cent Newer iterative reconstruction techniques have theoretical advantages in obese patients. aEuro cent Adaptive statistical iterative reconstruction should reduce image noise and radiation dose. aEuro cent This has been proven in abdominopelvic CT images of obese patients.
引用
收藏
页码:1631 / 1640
页数:10
相关论文
共 50 条
  • [31] CT evaluation of coronary artery stents with iterative image reconstruction: improvements in image quality and potential for radiation dose reduction
    Ebersberger, Ullrich
    Tricarico, Francesco
    Schoepf, U. Joseph
    Blanke, Philipp
    Spears, J. Reid
    Rowe, Garrett W.
    Halligan, William T.
    Henzler, Thomas
    Bamberg, Fabian
    Leber, Alexander W.
    Hoffmann, Ellen
    Apfaltrer, Paul
    EUROPEAN RADIOLOGY, 2013, 23 (01) : 125 - 132
  • [32] CT evaluation of coronary artery stents with iterative image reconstruction: improvements in image quality and potential for radiation dose reduction
    Ullrich Ebersberger
    Francesco Tricarico
    U. Joseph Schoepf
    Philipp Blanke
    J. Reid Spears
    Garrett W. Rowe
    William T. Halligan
    Thomas Henzler
    Fabian Bamberg
    Alexander W. Leber
    Ellen Hoffmann
    Paul Apfaltrer
    European Radiology, 2013, 23 : 125 - 132
  • [33] COMPARISON OF RADIATION DOSE AND IMAGE QUALITY IN HEAD CT SCANS AMONG MULTIDETECTOR CT SCANNERS
    Abuzaid, Mohamed M.
    Elshami, Wiam
    Tekin, H. O.
    Sulieman, Abdelmoneim
    Bradley, D. A.
    RADIATION PROTECTION DOSIMETRY, 2021, 196 (1-2) : 10 - 16
  • [34] CT Radiation Dose and Iterative Reconstruction Techniques
    Padole, Atul
    Khawaja, Ranish Deedar Ali
    Kalra, Mannudeep K.
    Singh, Sarabjeet
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (04) : W384 - W387
  • [35] Iterative Reconstruction Technique for Reducing Body Radiation Dose at CT: Feasibility Study
    Hara, Amy K.
    Paden, Robert G.
    Silva, Alvin C.
    Kujak, Jennifer L.
    Lawder, Holly J.
    Pavlicek, William
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (03) : 764 - 771
  • [36] Whole-body CT for lymphoma staging: Feasibility of halving radiation dose and risk by iterative image reconstruction
    Meyer, M.
    Klein, S. A.
    Brix, G.
    Fink, C.
    Pilz, L.
    Jafarov, H.
    Hofmann, W. K.
    Schoenberg, S. O.
    Henzler, T.
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (02) : 315 - 321
  • [37] The impact of tube current and iterative reconstruction algorithm on dose and image quality of infant CT head examination
    Muhammad, N. A.
    Karim, M. K. A.
    Harun, H. H.
    Rahman, M. A. A.
    Azlan, R. N. R. M.
    Sumardi, N. F.
    RADIATION PHYSICS AND CHEMISTRY, 2022, 200
  • [38] Chest CT at a dose below 0.3 mSv: impact of iterative reconstruction on image quality and lung analysis
    Nakajo, Chiaki
    Heinzer, Susanne
    Montandon, Stephane
    Dunet, Vincent
    Bize, Pierre
    Feldman, Andrei
    Beigelman-Aubry, Catherine
    ACTA RADIOLOGICA, 2016, 57 (03) : 311 - 317
  • [39] Impact of the adaptive statistical iterative reconstruction technique on image quality in ultra-low-dose CT
    Xu, Yan
    He, Wen
    Chen, Hui
    Hu, Zhihai
    Li, Juan
    Zhang, Tingting
    CLINICAL RADIOLOGY, 2013, 68 (09) : 902 - 908
  • [40] Adaptive statistical iterative reconstruction use for radiation dose reduction in pediatric lower-extremity CT: impact on diagnostic image quality
    Shah, Amisha
    Rees, Mitchell
    Kar, Erica
    Bolton, Kimberly
    Lee, Vincent
    Panigrahy, Ashok
    SKELETAL RADIOLOGY, 2018, 47 (06) : 785 - 793