Impact of iterative reconstruction on image quality and radiation dose in multidetector CT of large body size adults

被引:98
|
作者
Desai, Gaurav S. [2 ]
Uppot, Raul N. [2 ]
Yu, Elaine W. [3 ]
Kambadakone, Avinash R. [2 ]
Sahani, Dushyant V. [1 ,2 ]
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Div Abdominal Imaging & Intervent,Dept Radiol, Boston, MA 02114 USA
[2] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Abdominal Imaging & Intervent, Boston, MA 02114 USA
[3] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Endocrine Unit, Boston, MA 02114 USA
关键词
Iterative reconstruction; Computed tomography; Image quality; Radiation dose; Obesity; TUBE CURRENT MODULATION; ABDOMINAL CT; COMPUTED-TOMOGRAPHY; PATIENT SIZE; REDUCTION; EXPOSURE; OBESITY; ALGORITHM; MDCT; OPTIMIZATION;
D O I
10.1007/s00330-012-2424-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare image quality and radiation dose using Adaptive Statistical Iterative Reconstruction (ASiR) and Filtered Back Projection (FBP) in patients weighing a parts per thousand yen91 kg. In this Institution Review Board-approved retrospective study, single-phase contrast-enhanced abdominopelvic CT examinations of 100 adults weighing a parts per thousand yen91 kg (mean body weight: 107.6 +/- 17.4 kg range: 91-181.9 kg) with (1) ASiR and (2) FBP were reviewed by two readers in a blinded fashion for subjective measures of image quality (using a subjective standardized numerical scale and objective noise) and for radiation exposure. Imaging parameters and radiation dose results of the two techniques were compared within weight and BMI sub-categories. All examinations were found to be of adequate quality. Both subjective (mean = 1.4 +/- 0.5 vs. 1.6 +/- 0.6, P < 0.05) and objective noise (13.0 +/- 3.2 vs.19.5 +/- 5.7, P < 0.0001) were lower with ASiR. Average radiation dose reduction of 31.5 % was achieved using ASiR (mean CTDIvol. ASiR: 13.5 +/- 7.3 mGy; FBP: 19.7 +/- 9.0 mGy, P < 0.0001). Other measures of image quality were comparable between the two techniques. Trends for all parameters were similar in patients across weight and BMI sub-categories. In obese individuals, abdominal CT images reconstructed using ASiR provide diagnostic images with reduced image noise at lower radiation dose. aEuro cent CT images in obese adults are noisy, even with high radiation dose. aEuro cent Newer iterative reconstruction techniques have theoretical advantages in obese patients. aEuro cent Adaptive statistical iterative reconstruction should reduce image noise and radiation dose. aEuro cent This has been proven in abdominopelvic CT images of obese patients.
引用
收藏
页码:1631 / 1640
页数:10
相关论文
共 50 条
  • [11] A New Era in Computed Tomographic Dose Optimization: The Impact of Iterative Reconstruction on Image Quality and Radiation Dose
    Kordolaimi, Sofia D.
    Argentos, Stylianos
    Pantos, Ioannis
    Kelekis, Nikolaos L.
    Efstathopoulos, Efstathios P.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (06) : 924 - 931
  • [12] Impact of radiation dose reduction and iterative image reconstruction on CT-guided spine biopsies
    Karolin J. Paprottka
    Karina Kupfer
    Vivian Schultz
    Meinrad Beer
    Claus Zimmer
    Thomas Baum
    Jan S. Kirschke
    Nico Sollmann
    Scientific Reports, 13
  • [13] Impact of radiation dose reduction and iterative image reconstruction on CT-guided spine biopsies
    Paprottka, Karolin J.
    Kupfer, Karina
    Schultz, Vivian
    Beer, Meinrad
    Zimmer, Claus
    Baum, Thomas
    Kirschke, Jan S.
    Sollmann, Nico
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [14] Reducing CT radiation dose with iterative reconstruction algorithms: The influence of scan and reconstruction parameters on image quality and CTDIvol
    Klink, Thorsten
    Obmann, Verena
    Heverhagen, Johannes
    Stork, Alexander
    Adam, Gerhard
    Begemann, Philipp
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (09) : 1645 - 1654
  • [15] Objective assessment of image quality and dose reduction in CT iterative reconstruction
    Vaishnav, J. Y.
    Jung, W. C.
    Popescu, L. M.
    Zeng, R.
    Myers, K. J.
    MEDICAL PHYSICS, 2014, 41 (07)
  • [16] Multidetector-row CT image quality and radiation dose: Imaging the lung
    Judy, PF
    SEMINARS IN ROENTGENOLOGY, 2003, 38 (02) : 186 - 192
  • [17] Comparative assessment of three image reconstruction techniques for image quality and radiation dose in patients undergoing abdominopelvic multidetector CT examinations
    Desai, G. S.
    Thabet, A.
    Elias, A. Y. A.
    Sahani, D. V.
    BRITISH JOURNAL OF RADIOLOGY, 2013, 86 (1021):
  • [18] Adaptive Statistical Iterative Reconstruction of Body CT Data Reduces Dose While Maintaining Image Quality
    Kaplan, J.
    Simpson, W.
    Lee, K.
    Tanenbaum, L.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [19] Cranial CT with Adaptive Statistical Iterative Reconstruction: Improved Image Quality with Concomitant Radiation Dose Reduction
    Rapalino, O.
    Kamalian, Shervin
    Kamalian, Shahmir
    Payabvash, S.
    Souza, L. C. S.
    Zhang, D.
    Mukta, J.
    Sahani, D. V.
    Lev, M. H.
    Pomerantz, S. R.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (04) : 609 - 615
  • [20] Hybrid iterative reconstruction algorithm in brain CT: a radiation dose reduction and image quality assessment study
    Love, Askell
    Siemund, Roger
    Hoglund, Peter
    Van Westen, Danielle
    Stenberg, Lars
    Petersen, Cecilia
    Bjorkman-Burtscher, Isabella M.
    ACTA RADIOLOGICA, 2014, 55 (02) : 208 - 217