Robot-assisted percutaneous pedicle screw placement accuracy compared with alternative guidance in lateral single-position surgery: a systematic review and meta-analysis

被引:7
|
作者
Patel, Neal A. [1 ]
Kuo, Cathleen C. [2 ]
Pennington, Zach [3 ]
Brown, Nolan J. [4 ]
Gendreau, Julian [5 ]
Singh, Rohin [6 ]
Shahrestani, Shane [7 ,8 ]
Boyett, Candler [1 ]
Diaz-Aguilar, Luis Daniel [9 ]
Pham, Martin H. [9 ,10 ]
机构
[1] Mercer Univ, Sch Med, Columbus, GA USA
[2] Univ Buffalo, Dept Neurosurg, New York, NY USA
[3] Mayo Clin, Dept Neurosurg, Rochester, MN USA
[4] Univ Calif Irvine, Dept Neurosurg, Orange, CA USA
[5] Johns Hopkins Univ, Whiting Sch Engn, Dept Biomed Engn, Baltimore, MD 21218 USA
[6] Mayo Clin, Alix Sch Med, Scottsdale, AZ USA
[7] Univ Southern Calif, Keck Sch Med, Los Angeles, CA USA
[8] CALTECH, Dept Med Engn, Pasadena, CA 91125 USA
[9] Univ Calif San Diego, Dept Neurosurg, La Jolla, CA 92093 USA
[10] UC San Diego Hlth, La Jolla, CA 92122 USA
关键词
meta-analysis; percutaneous pedicle screw; screw accuracy; single-position surgery; robot-assisted; lumbar; LUMBAR INTERBODY FUSION; COMPUTED-TOMOGRAPHY; CIRCUMFERENTIAL FUSION; CLINICAL ACCURACY; FLUOROSCOPY; NAVIGATION; FIXATION;
D O I
10.3171/2023.3.SPINE2329
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE While single-position surgery (SPS) eliminates the need for patient repositioning, the placement of screws in the unconventional lateral position poses unique challenges related to asymmetry relative to the surgical table. Use of robotic guidance or intraoperative navigation can help to overcome this. The aim of this study was to compare the relative accuracies offered by these various navigation modalities for pedicle screws placed in lateral SPS. METHODS According to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, the PubMed/Medline, Embase, and Cochrane Library databases were queried for studies reporting pedicle screw placement accuracy using fluoroscopic, CT-navigated, O-arm, or robotic guidance in lateral SPS, and a systematic review and meta-analysis was performed. Included studies all compared evaluated screw placement accuracy in lateral SPS using a single navigation method. Quality assessment was performed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system; risk of bias was assessed using the Newcastle-Ottawa Scale and the Joanna Briggs Institute checklist. The primary outcome, rate of pedicle screw breach, was analyzed using random-effects meta-analysis. RESULTS Eleven studies were included comprising 548 patients who underwent the placement of instrumentation with 2488 screws. For the fluoroscopic, CT-navigated, O-arm, and robotic guidance cohorts, there were 3, 2, 3, and 3 studies, respectively. Breach rates by modality were as follows: fluoroscopic guidance (6.6%), CT navigation (4.7%), O-arm (3.9%), and robotic guidance (3.9%). Random-effects meta-analysis showed a significant difference between studies, with an overall breach rate of 4.9% (95% CI 3.1%-7.5%; p < 0.001); however, testing for subgroup differences failed to show a significant difference between guidance modalities (Q(M) = 0.69, df = 3; p = 0.88). Heterogeneity between studies was significant (I-2 = 79.0%, tau(2) = 0.41, chi(2) = 47.65, df = 10; p < 0.001). CONCLUSIONS Robotic guidance of screws is noninferior to alternative guidance modalities in lateral SPS; however, additional prospective studies directly comparing different guidance types are merited.
引用
收藏
页码:443 / 451
页数:9
相关论文
共 50 条
  • [41] Robot-assisted abdominal wall surgery: a systematic review of the literature and meta-analysis
    Henriksen, N. A.
    Jensen, K. K.
    Muysoms, F.
    HERNIA, 2019, 23 (01) : 17 - 27
  • [42] Robot-assisted abdominal wall surgery: a systematic review of the literature and meta-analysis
    N. A. Henriksen
    K. K. Jensen
    F. Muysoms
    Hernia, 2019, 23 : 17 - 27
  • [43] Robot-assisted hysterectomy compared to open and laparoscopic approaches: systematic review and meta-analysis
    Michelle O’Neill
    Patrick S. Moran
    Conor Teljeur
    Orfhlaith E. O’Sullivan
    Barry A. O’Reilly
    Matt Hewitt
    Martin Flattery
    Máirín Ryan
    Archives of Gynecology and Obstetrics, 2013, 287 : 907 - 918
  • [44] Robot-assisted hysterectomy compared to open and laparoscopic approaches: systematic review and meta-analysis
    O'Neill, Michelle
    Moran, Patrick S.
    Teljeur, Conor
    O'Sullivan, Orfhlaith E.
    O'Reilly, Barry A.
    Hewitt, Matt
    Flattery, Martin
    Ryan, Mairin
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2013, 287 (05) : 907 - 918
  • [45] Comparison of accuracy and safety between robot-assisted and conventional fluoroscope assisted placement of pedicle screws in thoracolumbar spine A meta-analysis
    Li, Chuntao
    Li, Wenyi
    Gao, Shangju
    Cao, Can
    Li, Changren
    He, Liang
    Ma, Xu
    Li, Meng
    MEDICINE, 2021, 100 (38)
  • [46] Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studies
    Tian, Nai-Feng
    Huang, Qi-Shan
    Zhou, Ping
    Zhou, Yang
    Wu, Rui-Kai
    Lou, Yi
    Xu, Hua-Zi
    EUROPEAN SPINE JOURNAL, 2011, 20 (06) : 846 - 859
  • [47] Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studies
    Nai-Feng Tian
    Qi-Shan Huang
    Ping Zhou
    Yang Zhou
    Rui-Kai Wu
    Yi Lou
    Hua-Zi Xu
    European Spine Journal, 2011, 20 : 846 - 859
  • [48] Accuracy of Pedicle Screw Placement and Clinical Outcomes of Robot-assisted Technique Versus Conventional Freehand Technique in Spine Surgery From Nine Randomized Controlled Trials: A Meta-analysis
    Li, Hui-Min
    Zhang, Ren-Jie
    Shen, Cai-Liang
    SPINE, 2020, 45 (02) : E111 - E119
  • [49] Does intraoperative CT navigation increase the accuracy of pedicle screw placement in pediatric spinal deformity surgery? A systematic review and meta-analysis
    Baldwin, Keith D.
    Kadiyala, Manasa
    Talwar, Divya
    Sankar, Wudbhav N.
    Flynn, John Jack M.
    Anari, Jason B.
    SPINE DEFORMITY, 2022, 10 (01) : 19 - 29
  • [50] Does intraoperative CT navigation increase the accuracy of pedicle screw placement in pediatric spinal deformity surgery? A systematic review and meta-analysis
    Keith D. Baldwin
    Manasa Kadiyala
    Divya Talwar
    Wudbhav N. Sankar
    John (Jack) M. Flynn
    Jason B. Anari
    Spine Deformity, 2022, 10 : 19 - 29