Robot-assisted percutaneous pedicle screw placement accuracy compared with alternative guidance in lateral single-position surgery: a systematic review and meta-analysis

被引:7
|
作者
Patel, Neal A. [1 ]
Kuo, Cathleen C. [2 ]
Pennington, Zach [3 ]
Brown, Nolan J. [4 ]
Gendreau, Julian [5 ]
Singh, Rohin [6 ]
Shahrestani, Shane [7 ,8 ]
Boyett, Candler [1 ]
Diaz-Aguilar, Luis Daniel [9 ]
Pham, Martin H. [9 ,10 ]
机构
[1] Mercer Univ, Sch Med, Columbus, GA USA
[2] Univ Buffalo, Dept Neurosurg, New York, NY USA
[3] Mayo Clin, Dept Neurosurg, Rochester, MN USA
[4] Univ Calif Irvine, Dept Neurosurg, Orange, CA USA
[5] Johns Hopkins Univ, Whiting Sch Engn, Dept Biomed Engn, Baltimore, MD 21218 USA
[6] Mayo Clin, Alix Sch Med, Scottsdale, AZ USA
[7] Univ Southern Calif, Keck Sch Med, Los Angeles, CA USA
[8] CALTECH, Dept Med Engn, Pasadena, CA 91125 USA
[9] Univ Calif San Diego, Dept Neurosurg, La Jolla, CA 92093 USA
[10] UC San Diego Hlth, La Jolla, CA 92122 USA
关键词
meta-analysis; percutaneous pedicle screw; screw accuracy; single-position surgery; robot-assisted; lumbar; LUMBAR INTERBODY FUSION; COMPUTED-TOMOGRAPHY; CIRCUMFERENTIAL FUSION; CLINICAL ACCURACY; FLUOROSCOPY; NAVIGATION; FIXATION;
D O I
10.3171/2023.3.SPINE2329
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE While single-position surgery (SPS) eliminates the need for patient repositioning, the placement of screws in the unconventional lateral position poses unique challenges related to asymmetry relative to the surgical table. Use of robotic guidance or intraoperative navigation can help to overcome this. The aim of this study was to compare the relative accuracies offered by these various navigation modalities for pedicle screws placed in lateral SPS. METHODS According to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, the PubMed/Medline, Embase, and Cochrane Library databases were queried for studies reporting pedicle screw placement accuracy using fluoroscopic, CT-navigated, O-arm, or robotic guidance in lateral SPS, and a systematic review and meta-analysis was performed. Included studies all compared evaluated screw placement accuracy in lateral SPS using a single navigation method. Quality assessment was performed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system; risk of bias was assessed using the Newcastle-Ottawa Scale and the Joanna Briggs Institute checklist. The primary outcome, rate of pedicle screw breach, was analyzed using random-effects meta-analysis. RESULTS Eleven studies were included comprising 548 patients who underwent the placement of instrumentation with 2488 screws. For the fluoroscopic, CT-navigated, O-arm, and robotic guidance cohorts, there were 3, 2, 3, and 3 studies, respectively. Breach rates by modality were as follows: fluoroscopic guidance (6.6%), CT navigation (4.7%), O-arm (3.9%), and robotic guidance (3.9%). Random-effects meta-analysis showed a significant difference between studies, with an overall breach rate of 4.9% (95% CI 3.1%-7.5%; p < 0.001); however, testing for subgroup differences failed to show a significant difference between guidance modalities (Q(M) = 0.69, df = 3; p = 0.88). Heterogeneity between studies was significant (I-2 = 79.0%, tau(2) = 0.41, chi(2) = 47.65, df = 10; p < 0.001). CONCLUSIONS Robotic guidance of screws is noninferior to alternative guidance modalities in lateral SPS; however, additional prospective studies directly comparing different guidance types are merited.
引用
收藏
页码:443 / 451
页数:9
相关论文
共 50 条
  • [21] Accuracy assessment of robot-assisted implant surgery in dentistry: A systematic review and meta-analysis
    Yang, Jun
    Li, Hainan
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (04):
  • [22] The safety and accuracy of robot-assisted pedicle screw internal fixation for spine disease A META-ANALYSIS
    Li, W.
    Li, G.
    Chen, W.
    Cong, L.
    BONE & JOINT RESEARCH, 2020, 9 (10): : 653 - 666
  • [23] Safety and risk factors of TINAVI robot-assisted percutaneous pedicle screw placement in spinal surgery
    Zhang, Ren-Jie
    Zhou, Lu-Ping
    Zhang, Lai
    Zhang, Hua-Qing
    Zhang, Jian-Xiang
    Shen, Cai-Liang
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [24] Safety and risk factors of TINAVI robot-assisted percutaneous pedicle screw placement in spinal surgery
    Ren-Jie Zhang
    Lu-Ping Zhou
    Lai Zhang
    Hua-Qing Zhang
    Jian-Xiang Zhang
    Cai-Liang Shen
    Journal of Orthopaedic Surgery and Research, 17
  • [25] Robotic-Assisted Versus Fluoroscopic-Guided Surgery on the Accuracy of Spine Pedicle Screw Placement: A Systematic Review and Meta-Analysis
    Jung, Bongseok
    Han, Justin
    Shahsavarani, Shaya
    Abbas, Anas M.
    Echevarria, Alexandra C.
    Carrier, Robert E.
    Ngan, Alex
    Katz, Austen D.
    Essig, David
    Verma, Rohit
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (02)
  • [26] A Systematic Review and Meta-analysis of Randomized Controlled Trials Comparing the Accuracy and Clinical Outcome of Pedicle Screw Placement Using Robot-Assisted Technology and Conventional Freehand Technique
    Tarawneh, Ahmad M.
    Salem, Khalid MI.
    GLOBAL SPINE JOURNAL, 2021, 11 (04) : 575 - 586
  • [27] Accuracy of Robot-Assisted Percutaneous Pedicle Screw Placement under Regional Anesthesia: A Retrospective Cohort Study
    Gao, Shangju
    Wei, Jingchao
    Li, Wenyi
    Zhang, Long
    Cao, Can
    Zhai, Jinshuai
    Gao, Bo
    PAIN RESEARCH & MANAGEMENT, 2021, 2021
  • [28] Accuracy of Robot-Assisted Percutaneous Pedicle Screw Placement for Treatment of Lumbar Spondylolisthesis: A Comparative Cohort Study
    Yang, Jun-Song
    He, Baorong
    Tian, Fang
    Liu, Tuan-Jiang
    Liu, Peng
    Zhang, Jia-Nan
    Liu, Shi-Chang
    Tuo, Yuan
    Chu, Lei
    Hao, Ding-Jun
    MEDICAL SCIENCE MONITOR, 2019, 25 : 2479 - 2487
  • [29] Simultaneous Single-Position Lateral Lumbar Interbody Fusion Surgery and Unilateral Percutaneous Pedicle Screw Fixation for Spondylolisthesis
    Lv, Hui
    Yang, Yu Sheng
    Zhou, Jian Hong
    Guo, Yuan
    Chen, Hui
    Luo, Fei
    Xu, Jian Zhong
    Zhang, Zhong Rong
    Zhang, Ze Hua
    NEUROSPINE, 2023, 20 (03) : 824 - 834
  • [30] Positioning accuracy and facet joints violation after percutaneous pedicle screws placement with robot-assisted versus fluoroscopy-guided technique: Systematic review and meta-analysis
    Perna, Andrea
    Velluto, Calogero
    Smakaj, Amarildo
    Tamburrelli, Francesco
    Borruto, Maria Ilaria
    Santagada, Domenico Alessandro
    Gorgoglione, Franco Lucio
    Liuzza, Francesco
    Proietti, Luca
    JOURNAL OF NEUROSCIENCES IN RURAL PRACTICE, 2023, 14 (03) : 406 - 412