Robot-assisted percutaneous pedicle screw placement accuracy compared with alternative guidance in lateral single-position surgery: a systematic review and meta-analysis

被引:7
|
作者
Patel, Neal A. [1 ]
Kuo, Cathleen C. [2 ]
Pennington, Zach [3 ]
Brown, Nolan J. [4 ]
Gendreau, Julian [5 ]
Singh, Rohin [6 ]
Shahrestani, Shane [7 ,8 ]
Boyett, Candler [1 ]
Diaz-Aguilar, Luis Daniel [9 ]
Pham, Martin H. [9 ,10 ]
机构
[1] Mercer Univ, Sch Med, Columbus, GA USA
[2] Univ Buffalo, Dept Neurosurg, New York, NY USA
[3] Mayo Clin, Dept Neurosurg, Rochester, MN USA
[4] Univ Calif Irvine, Dept Neurosurg, Orange, CA USA
[5] Johns Hopkins Univ, Whiting Sch Engn, Dept Biomed Engn, Baltimore, MD 21218 USA
[6] Mayo Clin, Alix Sch Med, Scottsdale, AZ USA
[7] Univ Southern Calif, Keck Sch Med, Los Angeles, CA USA
[8] CALTECH, Dept Med Engn, Pasadena, CA 91125 USA
[9] Univ Calif San Diego, Dept Neurosurg, La Jolla, CA 92093 USA
[10] UC San Diego Hlth, La Jolla, CA 92122 USA
关键词
meta-analysis; percutaneous pedicle screw; screw accuracy; single-position surgery; robot-assisted; lumbar; LUMBAR INTERBODY FUSION; COMPUTED-TOMOGRAPHY; CIRCUMFERENTIAL FUSION; CLINICAL ACCURACY; FLUOROSCOPY; NAVIGATION; FIXATION;
D O I
10.3171/2023.3.SPINE2329
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE While single-position surgery (SPS) eliminates the need for patient repositioning, the placement of screws in the unconventional lateral position poses unique challenges related to asymmetry relative to the surgical table. Use of robotic guidance or intraoperative navigation can help to overcome this. The aim of this study was to compare the relative accuracies offered by these various navigation modalities for pedicle screws placed in lateral SPS. METHODS According to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, the PubMed/Medline, Embase, and Cochrane Library databases were queried for studies reporting pedicle screw placement accuracy using fluoroscopic, CT-navigated, O-arm, or robotic guidance in lateral SPS, and a systematic review and meta-analysis was performed. Included studies all compared evaluated screw placement accuracy in lateral SPS using a single navigation method. Quality assessment was performed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system; risk of bias was assessed using the Newcastle-Ottawa Scale and the Joanna Briggs Institute checklist. The primary outcome, rate of pedicle screw breach, was analyzed using random-effects meta-analysis. RESULTS Eleven studies were included comprising 548 patients who underwent the placement of instrumentation with 2488 screws. For the fluoroscopic, CT-navigated, O-arm, and robotic guidance cohorts, there were 3, 2, 3, and 3 studies, respectively. Breach rates by modality were as follows: fluoroscopic guidance (6.6%), CT navigation (4.7%), O-arm (3.9%), and robotic guidance (3.9%). Random-effects meta-analysis showed a significant difference between studies, with an overall breach rate of 4.9% (95% CI 3.1%-7.5%; p < 0.001); however, testing for subgroup differences failed to show a significant difference between guidance modalities (Q(M) = 0.69, df = 3; p = 0.88). Heterogeneity between studies was significant (I-2 = 79.0%, tau(2) = 0.41, chi(2) = 47.65, df = 10; p < 0.001). CONCLUSIONS Robotic guidance of screws is noninferior to alternative guidance modalities in lateral SPS; however, additional prospective studies directly comparing different guidance types are merited.
引用
收藏
页码:443 / 451
页数:9
相关论文
共 50 条
  • [31] Accuracy and clinical characteristics of robot-assisted cervical spine surgery: a systematic review and meta-analysis
    Wu, Jiayuan
    Fan, Mingxing
    He, Da
    Wei, Yi
    Duan, Fangfang
    Jiang, Xieyuan
    Tian, Wei
    INTERNATIONAL ORTHOPAEDICS, 2024, 48 (07) : 1903 - 1914
  • [32] Is robot-assisted pedicle screw placement really superior to conventional surgery? An overview of systematic reviews and meta-analyses
    Sun, Wen-Xi
    Qiu, Ming-Wang
    Gao, Ze-Hui
    Wang, Hong-Shen
    Chen, Bo-Lai
    Lin, Yong-Peng
    EFORT OPEN REVIEWS, 2024, 9 (11) : 1077 - 1086
  • [33] Association of robot-assisted techniques with the accuracy rates of pedicle screw placement: A network pooling analysis
    Wei, Fei-Long
    Gao, Quan-You
    Heng, Wei
    Zhu, Kai-Long
    Yang, Fan
    Du, Ming-Rui
    Zhou, Cheng-Pei
    Qian, Ji-Xian
    Yan, Xiao-Dong
    ECLINICALMEDICINE, 2022, 48
  • [34] Technique, Safety, and Accuracy Assessment of Percutaneous Pedicle Screw Placement Utilizing Computer- Assisted Navigation in Lateral Decubitus Single- Position Surgery
    Calek, Anna-Katharina
    Hochreiter, Bettina
    Buckland, Aaron J.
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2024, 18 (04):
  • [35] Accuracy of pedicle screw placement comparing robot-assisted technology and the free-hand with fluoroscopy-guided method in spine surgery: An updated meta-analysis
    Fan, Yong
    Du, Jin Peng
    Liu, Ji Jun
    Zhang, Jia Nan
    Qiao, Huan Huan
    Liu, Shi Chang
    Hao, Ding Jun
    MEDICINE, 2018, 97 (22)
  • [36] Commentary on "Simultaneous Single-Position Lateral Lumbar Interbody Fusion Surgery and Unilateral Percutaneous Pedicle Screw Fixation for Spondylolisthesis"
    Toktas, Zafer Orkun
    NEUROSPINE, 2023, 20 (03) : 835 - 836
  • [37] Accuracy of implant placement with computer-aided static, dynamic, and robot-assisted surgery: a systematic review and meta-analysis of clinical trials
    Angkoon Khaohoen
    Warit Powcharoen
    Tanapon Sornsuwan
    Pisaisit Chaijareenont
    Chaiy Rungsiyakull
    Pimduen Rungsiyakull
    BMC Oral Health, 24
  • [38] Accuracy of implant placement with computer-aided static, dynamic, and robot-assisted surgery: a systematic review and meta-analysis of clinical trials
    Khaohoen, Angkoon
    Powcharoen, Warit
    Sornsuwan, Tanapon
    Chaijareenont, Pisaisit
    Rungsiyakull, Chaiy
    Rungsiyakull, Pimduen
    BMC ORAL HEALTH, 2024, 24 (01)
  • [39] Accuracy and safety of C2 pedicle or pars screw placement: a systematic review and meta-analysis
    Azimi, Parisa
    Yazdanian, Taravat
    Benzel, Edward C.
    Aghaei, Hossein Nayeb
    Azhari, Shirzad
    Sadeghi, Sohrab
    Montazeri, Ali
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [40] Accuracy and safety of C2 pedicle or pars screw placement: a systematic review and meta-analysis
    Parisa Azimi
    Taravat Yazdanian
    Edward C. Benzel
    Hossein Nayeb Aghaei
    Shirzad Azhari
    Sohrab Sadeghi
    Ali Montazeri
    Journal of Orthopaedic Surgery and Research, 15