Does intraoperative CT navigation increase the accuracy of pedicle screw placement in pediatric spinal deformity surgery? A systematic review and meta-analysis

被引:33
|
作者
Baldwin, Keith D. [1 ,2 ]
Kadiyala, Manasa [2 ]
Talwar, Divya [1 ]
Sankar, Wudbhav N. [1 ]
Flynn, John Jack M. [1 ]
Anari, Jason B. [1 ]
机构
[1] Childrens Hosp Philadelphia, Div Orthopaed, Philadelphia, PA 19104 USA
[2] Univ Penn, Perelman Sch Med, Philadelphia, PA 19104 USA
关键词
Pediatric Spinal deformity; Navigation; Intraoperative imaging; surgical safety; TOMOGRAPHY-GUIDED NAVIGATION; DOSE O-ARM; COMPUTED-TOMOGRAPHY; IDIOPATHIC SCOLIOSIS; RADIATION-EXPOSURE; OPERATING-ROOM; AORTIC INJURY; PATIENT; FLUOROSCOPY; COMPLICATIONS;
D O I
10.1007/s43390-021-00385-5
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose Although pediatric spinal deformity correction using pedicle screws has a very low rate of complications, the long-term consequences of screw malposition is unknown. CT navigation has been proposed to improve screw accuracy. The aim of this study was to determine whether intraoperative navigation during pedicle screw placement in pediatric scoliosis makes screw placement more accurate. We also examined radiation exposure, operative time blood loss and complications with and without the use of CT navigation in pediatric spinal deformity surgery. Methods A systematic review of the literature was conducted. After screening, 13 articles were qualitatively and quantitatively analyzed to be used for the review. A random effects meta-analysis using REML methodology was employed to compare outcomes of screw accuracy, estimated blood loss, radiation exposure, and surgical duration. Results Screws placed with CT navigation surgery were three times as likely to be deemed "acceptable" compared with screws placed with freehand and 2D fluoroscopy assistance, twice as likely to be "perfect", and only 1/3 as likely to be potentially unsafe (all p value < 0.01). EBL was not significantly different between groups; however, operative time was roughly thirty minutes longer on average. Random effects analysis showed no significant difference in effective dose radiation while using CT navigation (p = 0.06). Conclusion This systematic review of the literature demonstrates that intraoperative navigation results in more accurate pedicle screw placement compared to non-navigated techniques. We found that blood loss was similar in navigated and non-navigated surgery. Operative time was found to be approximately a half hour longer on average in navigated compared to non-navigated surgery. Effective radiation dose trended higher in navigated cases compared to non-navigated cases but did not reach statistical significance.
引用
收藏
页码:19 / 29
页数:11
相关论文
共 50 条
  • [1] Does intraoperative CT navigation increase the accuracy of pedicle screw placement in pediatric spinal deformity surgery? A systematic review and meta-analysis
    Keith D. Baldwin
    Manasa Kadiyala
    Divya Talwar
    Wudbhav N. Sankar
    John (Jack) M. Flynn
    Jason B. Anari
    Spine Deformity, 2022, 10 : 19 - 29
  • [2] Accuracy of Pedicle Screw Placement Methods in Pediatrics and Adolescents Spinal Surgery: A Systematic Review and Meta-Analysis
    De Vega, Brigita
    Navarro, Aida Ribera
    Gibson, Alexander
    Kalaskar, Deepak M.
    GLOBAL SPINE JOURNAL, 2022, 12 (04) : 677 - 688
  • [3] 3D-printed drill guide template, a promising tool to improve pedicle screw placement accuracy in spinal deformity surgery: A systematic review and meta-analysis
    Weishi Liang
    Bo Han
    Junrui Jonathan Hai
    Yong Hai
    Long Chen
    Nan Kang
    Peng Yin
    European Spine Journal, 2021, 30 : 1173 - 1183
  • [4] 3D-printed drill guide template, a promising tool to improve pedicle screw placement accuracy in spinal deformity surgery: A systematic review and meta-analysis
    Liang, Weishi
    Han, Bo
    Hai, Junrui Jonathan
    Hai, Yong
    Chen, Long
    Kang, Nan
    Yin, Peng
    EUROPEAN SPINE JOURNAL, 2021, 30 (05) : 1173 - 1183
  • [5] Pedicle screw placement accuracy - A meta-analysis
    Kosmopoulos, Victor
    Schizas, Constantin
    SPINE, 2007, 32 (03) : E111 - E120
  • [6] A Novel Intraoperative CT Navigation System for Spinal Fusion Surgery in Lumbar Degenerative Disease: Accuracy and Safety of Pedicle Screw Placement
    Kanno, Haruo
    Handa, Kyoichi
    Murotani, Motoki
    Ozawa, Hiroshi
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (07)
  • [7] Assessing Procedural Accuracy in Lateral Spine Surgery: A Retrospective Analysis of Percutaneous Pedicle Screw Placement with Intraoperative CT Navigation
    Hiyama, Akihiko
    Sakai, Daisuke
    Katoh, Hiroyuki
    Nomura, Satoshi
    Watanabe, Masahiko
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (21)
  • [8] Intraoperative computerized tomography for improved accuracy of spinal navigation in pedicle screw placement of the thoracic spine
    Ebmeier, K
    Giest, K
    Kalff, R
    INTRAOPERATIVE IMAGING IN NEUROSURGERY: MRI, CT, ULTRASOUND, 2003, 85 : 105 - 113
  • [9] Accuracy and safety of C2 pedicle or pars screw placement: a systematic review and meta-analysis
    Azimi, Parisa
    Yazdanian, Taravat
    Benzel, Edward C.
    Aghaei, Hossein Nayeb
    Azhari, Shirzad
    Sadeghi, Sohrab
    Montazeri, Ali
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [10] Accuracy and safety of C2 pedicle or pars screw placement: a systematic review and meta-analysis
    Parisa Azimi
    Taravat Yazdanian
    Edward C. Benzel
    Hossein Nayeb Aghaei
    Shirzad Azhari
    Sohrab Sadeghi
    Ali Montazeri
    Journal of Orthopaedic Surgery and Research, 15