Does intraoperative CT navigation increase the accuracy of pedicle screw placement in pediatric spinal deformity surgery? A systematic review and meta-analysis

被引:33
|
作者
Baldwin, Keith D. [1 ,2 ]
Kadiyala, Manasa [2 ]
Talwar, Divya [1 ]
Sankar, Wudbhav N. [1 ]
Flynn, John Jack M. [1 ]
Anari, Jason B. [1 ]
机构
[1] Childrens Hosp Philadelphia, Div Orthopaed, Philadelphia, PA 19104 USA
[2] Univ Penn, Perelman Sch Med, Philadelphia, PA 19104 USA
关键词
Pediatric Spinal deformity; Navigation; Intraoperative imaging; surgical safety; TOMOGRAPHY-GUIDED NAVIGATION; DOSE O-ARM; COMPUTED-TOMOGRAPHY; IDIOPATHIC SCOLIOSIS; RADIATION-EXPOSURE; OPERATING-ROOM; AORTIC INJURY; PATIENT; FLUOROSCOPY; COMPLICATIONS;
D O I
10.1007/s43390-021-00385-5
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose Although pediatric spinal deformity correction using pedicle screws has a very low rate of complications, the long-term consequences of screw malposition is unknown. CT navigation has been proposed to improve screw accuracy. The aim of this study was to determine whether intraoperative navigation during pedicle screw placement in pediatric scoliosis makes screw placement more accurate. We also examined radiation exposure, operative time blood loss and complications with and without the use of CT navigation in pediatric spinal deformity surgery. Methods A systematic review of the literature was conducted. After screening, 13 articles were qualitatively and quantitatively analyzed to be used for the review. A random effects meta-analysis using REML methodology was employed to compare outcomes of screw accuracy, estimated blood loss, radiation exposure, and surgical duration. Results Screws placed with CT navigation surgery were three times as likely to be deemed "acceptable" compared with screws placed with freehand and 2D fluoroscopy assistance, twice as likely to be "perfect", and only 1/3 as likely to be potentially unsafe (all p value < 0.01). EBL was not significantly different between groups; however, operative time was roughly thirty minutes longer on average. Random effects analysis showed no significant difference in effective dose radiation while using CT navigation (p = 0.06). Conclusion This systematic review of the literature demonstrates that intraoperative navigation results in more accurate pedicle screw placement compared to non-navigated techniques. We found that blood loss was similar in navigated and non-navigated surgery. Operative time was found to be approximately a half hour longer on average in navigated compared to non-navigated surgery. Effective radiation dose trended higher in navigated cases compared to non-navigated cases but did not reach statistical significance.
引用
收藏
页码:19 / 29
页数:11
相关论文
共 50 条
  • [21] Comparison of the accuracy between robot-assisted and conventional freehand pedicle screw placement: a systematic review and meta-analysis
    Liu, Hao
    Chen, Weikai
    Wang, Zongyi
    Lin, Jun
    Meng, Bin
    Yang, Huilin
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2016, 11 (12) : 2273 - 2281
  • [22] Comparison of the accuracy between robot-assisted and conventional freehand pedicle screw placement: a systematic review and meta-analysis
    Hao Liu
    Weikai Chen
    Zongyi Wang
    Jun Lin
    Bin Meng
    Huilin Yang
    International Journal of Computer Assisted Radiology and Surgery, 2016, 11 : 2273 - 2281
  • [23] A systematic review with meta-analysis of the diagnostic test accuracy of pedicle screw electrical stimulation
    Pedro Fonseca
    Márcio Goethel
    João Paulo Vilas-Boas
    Manuel Gutierres
    Miguel Velhote Correia
    European Spine Journal, 2022, 31 : 1599 - 1610
  • [24] A systematic review with meta-analysis of the diagnostic test accuracy of pedicle screw electrical stimulation
    Fonseca, Pedro
    Goethel, Marcio
    Vilas-Boas, Joao Paulo
    Gutierres, Manuel
    Correia, Miguel Velhote
    EUROPEAN SPINE JOURNAL, 2022, 31 (07) : 1599 - 1610
  • [25] Meta-analysis of fluoroscopic and navigation-based cervical pedicle screw placement
    Soliman, Mohamed A. R.
    Khan, Asham
    Pollina, John
    Mullin, Jeffrey P.
    JOURNAL OF NEUROSURGERY-SPINE, 2022, 36 (03) : 522 - 523
  • [26] Comparison of the perioperative parameters between computer navigation and fluoroscopy guidance for pedicle screw placement A protocol for a systematic review and meta-analysis
    Li, Qianchun
    Chen, Botao
    Chen, Rigao
    Yu, Yang
    Jiang, Leiming
    Fan, Xiaohong
    MEDICINE, 2020, 99 (28) : E21064
  • [27] Accuracy of Pedicle Screw Placement Using Intraoperative CT-Guided Navigation and Conventional Fluoroscopy for Lumbar Spondylosis
    Alqurashi, Ashwaq
    Alomar, Soha A.
    Bakhaidar, Mohamad
    Alfiky, Mohammed
    Baeesa, Saleh S.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (08)
  • [28] Accuracy of dynamic navigation in implant surgery: A systematic review and meta-analysis
    Wei, Shi-Min
    Zhu, Yu
    Wei, Jian-Xu
    Zhang, Chu-Nan
    Shi, Jun-Yu
    Lai, Hong-Chang
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (04) : 383 - 393
  • [29] Accuracy of robot-assisted versus conventional freehand pedicle screw placement in spine surgery: a systematic review and meta-analysis of randomized controlled trials
    Peng, Yu-Ning
    Tsai, Li-Cheng
    Hsu, Horng-Chaung
    Kao, Chia-Hung
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (13)
  • [30] Accuracy of Intraoperative Neuromonitoring in the Diagnosis of Intraoperative Neurological Decline in the Setting of Spinal Surgery-A Systematic Review and Meta-Analysis
    Alvi, Mohammed Ali
    Kwon, Brian K.
    Hejrati, Nader
    Tetreault, Lindsay A.
    Evaniew, Nathan
    Skelly, Andrea C.
    Fehlings, Michael G.
    GLOBAL SPINE JOURNAL, 2024, 14 (3_SUPPL) : 105S - 149S