Does intraoperative CT navigation increase the accuracy of pedicle screw placement in pediatric spinal deformity surgery? A systematic review and meta-analysis

被引:33
|
作者
Baldwin, Keith D. [1 ,2 ]
Kadiyala, Manasa [2 ]
Talwar, Divya [1 ]
Sankar, Wudbhav N. [1 ]
Flynn, John Jack M. [1 ]
Anari, Jason B. [1 ]
机构
[1] Childrens Hosp Philadelphia, Div Orthopaed, Philadelphia, PA 19104 USA
[2] Univ Penn, Perelman Sch Med, Philadelphia, PA 19104 USA
关键词
Pediatric Spinal deformity; Navigation; Intraoperative imaging; surgical safety; TOMOGRAPHY-GUIDED NAVIGATION; DOSE O-ARM; COMPUTED-TOMOGRAPHY; IDIOPATHIC SCOLIOSIS; RADIATION-EXPOSURE; OPERATING-ROOM; AORTIC INJURY; PATIENT; FLUOROSCOPY; COMPLICATIONS;
D O I
10.1007/s43390-021-00385-5
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose Although pediatric spinal deformity correction using pedicle screws has a very low rate of complications, the long-term consequences of screw malposition is unknown. CT navigation has been proposed to improve screw accuracy. The aim of this study was to determine whether intraoperative navigation during pedicle screw placement in pediatric scoliosis makes screw placement more accurate. We also examined radiation exposure, operative time blood loss and complications with and without the use of CT navigation in pediatric spinal deformity surgery. Methods A systematic review of the literature was conducted. After screening, 13 articles were qualitatively and quantitatively analyzed to be used for the review. A random effects meta-analysis using REML methodology was employed to compare outcomes of screw accuracy, estimated blood loss, radiation exposure, and surgical duration. Results Screws placed with CT navigation surgery were three times as likely to be deemed "acceptable" compared with screws placed with freehand and 2D fluoroscopy assistance, twice as likely to be "perfect", and only 1/3 as likely to be potentially unsafe (all p value < 0.01). EBL was not significantly different between groups; however, operative time was roughly thirty minutes longer on average. Random effects analysis showed no significant difference in effective dose radiation while using CT navigation (p = 0.06). Conclusion This systematic review of the literature demonstrates that intraoperative navigation results in more accurate pedicle screw placement compared to non-navigated techniques. We found that blood loss was similar in navigated and non-navigated surgery. Operative time was found to be approximately a half hour longer on average in navigated compared to non-navigated surgery. Effective radiation dose trended higher in navigated cases compared to non-navigated cases but did not reach statistical significance.
引用
收藏
页码:19 / 29
页数:11
相关论文
共 50 条
  • [31] The comparative accuracy and safety of fluoroscopic and navigation-based techniques in cervical pedicle screw fixation: systematic review and meta-analysis
    Tarawneh, Ahmad M.
    Haleem, Shahnawaz
    D'Aquino, Daniel
    Quraishi, Nasir
    JOURNAL OF NEUROSURGERY-SPINE, 2021, 35 (02) : 194 - 201
  • [32] Comparative efficacy of robotic-assisted and freehand techniques for pedicle screw placement in spinal disorders: a meta-analysis and systematic review
    Yang, Zhanhua
    Sun, Yuhang
    Deng, Changcui
    Dong, Xiuhui
    Hao, Liansheng
    JOURNAL OF ROBOTIC SURGERY, 2024, 18 (01)
  • [33] Computer navigation versus fluoroscopy-guided navigation for thoracic pedicle screw placement: a meta-analysis
    Xiao-tong Meng
    Xiao-fei Guan
    Hai-long Zhang
    Shi-sheng He
    Neurosurgical Review, 2016, 39 : 385 - 391
  • [34] Computer navigation versus fluoroscopy-guided navigation for thoracic pedicle screw placement: a meta-analysis
    Meng, Xiao-tong
    Guan, Xiao-fei
    Zhang, Hai-long
    He, Shi-sheng
    NEUROSURGICAL REVIEW, 2016, 39 (03) : 385 - 391
  • [35] Risk factors for surgical site infection following pediatric spinal deformity surgery: a systematic review and meta-analysis
    Meng, Fei
    Cao, Junming
    Meng, Xianzhong
    CHILDS NERVOUS SYSTEM, 2015, 31 (04) : 521 - 527
  • [36] Risk factors for surgical site infection following pediatric spinal deformity surgery: a systematic review and meta-analysis
    Fei Meng
    Junming Cao
    Xianzhong Meng
    Child's Nervous System, 2015, 31 : 521 - 527
  • [37] Robot-assisted percutaneous pedicle screw placement accuracy compared with alternative guidance in lateral single-position surgery: a systematic review and meta-analysis
    Patel, Neal A.
    Kuo, Cathleen C.
    Pennington, Zach
    Brown, Nolan J.
    Gendreau, Julian
    Singh, Rohin
    Shahrestani, Shane
    Boyett, Candler
    Diaz-Aguilar, Luis Daniel
    Pham, Martin H.
    JOURNAL OF NEUROSURGERY-SPINE, 2023, 39 (04) : 443 - 451
  • [38] Evaluating robotic pedicle screw placement against conventional modalities: a systematic review and network meta-analysis
    Naik, Anant
    Smith, Alexander D.
    Shaffer, Annabelle
    Krist, David T.
    Moawad, Christina M.
    MacInnis, Bailey R.
    Teal, Kevin
    Hassaneen, Wael
    Arnold, Paul M.
    NEUROSURGICAL FOCUS, 2022, 52 (01)
  • [39] Three-Dimensional Printing for Preoperative Planning and Pedicle Screw Placement in Adult Spinal Deformity: A Systematic Review
    Lopez, Cesar D.
    Boddapati, Venkat
    Lee, Nathan J.
    Dyrszka, Marc D.
    Sardar, Zeeshan M.
    Lehman, Ronald A.
    Lenke, Lawrence G.
    GLOBAL SPINE JOURNAL, 2021, 11 (06) : 936 - 949
  • [40] True accuracy of percutaneous pedicle screw placement in thoracic and lumbar spinal fixation with a CT-based navigation system: Intraoperative and postoperative assessment of 763 percutaneous pedicle screws
    Ouchida, Jun
    Kanemura, Tokumi
    Satake, Kotaro
    Nakashima, Hiroaki
    Segi, Naoki
    Suzuki, Kanae
    Imagama, Shiro
    JOURNAL OF CLINICAL NEUROSCIENCE, 2020, 79 : 1 - 6