Dosimetric delivery validation of dynamically collimated pencil beam scanning proton therapy

被引:4
|
作者
Nelson, Nicholas P. [1 ]
Culberson, Wesley S. [1 ]
Hyer, Daniel E. [2 ]
Geoghegan, Theodore J. [2 ]
Patwardhan, Kaustubh A. [2 ]
Smith, Blake R. [2 ]
Flynn, Ryan T. [2 ]
Yu, Jen [3 ]
Gutierrez, Alonso N. [3 ]
Hill, Patrick M. [4 ]
机构
[1] Univ Wisconsin Madison, Sch Med & Publ Hlth, Dept Med Phys, 1111 Highland Ave, Madison, WI 53705 USA
[2] Univ Iowa Hosp & Clin, Dept Radiat Oncol, 200 Hawkins Dr, Iowa City, IA 52242 USA
[3] Baptist Hlth South Florida, Miami Canc Inst, Dept Radiat Oncol, 8900 N Kendall Dr, Miami, FL 33176 USA
[4] Univ Wisconsin Madison, Sch Med & Publ Hlth, Dept Human Oncol, 600 Highland Ave, Madison, WI 53792 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2023年 / 68卷 / 05期
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
proton therapy; collimation; Monte Carlo; dosimetry; IONIZATION-CHAMBER ARRAY; BRAIN-TUMORS; SPOT SIZE; QUALITY; SYSTEM; IMPACT;
D O I
10.1088/1361-6560/acb6cd
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Pencil beam scanning (PBS) proton therapy target dose conformity can be improved with energy layer-specific collimation. One such collimator is the dynamic collimation system (DCS), which consists of four nickel trimmer blades that intercept the scanning beam as it approaches the lateral extent of the target. While the dosimetric benefits of the DCS have been demonstrated through computational treatment planning studies, there has yet to be experimental verification of these benefits for composite multi-energy layer fields. The objective of this work is to dosimetrically characterize and experimentally validate the delivery of dynamically collimated proton therapy with the DCS equipped to a clinical PBS system. Approach. Optimized single field, uniform dose treatment plans for 3 x 3 x 3 cm(3) target volumes were generated using Monte Carlo dose calculations with depths ranging from 5 to 15 cm, trimmer-to-surface distances ranging from 5 to 18.15 cm, with and without a 4 cm thick polyethylene range shifter. Treatment plans were then delivered to a water phantom using a prototype DCS and an IBA dedicated nozzle system and measured with a Zebra multilayer ionization chamber, a MatriXX PT ionization chamber array, and Gafchromic (TM) EBT3 film. Main results. For measurements made within the SOBPs, average 2D gamma pass rates exceeded 98.5% for the MatriXX PT and 96.5% for film at the 2%/2 mm criterion across all measured uncollimated and collimated plans, respectively. For verification of the penumbra width reduction with collimation, film agreed with Monte Carlo with differences within 0.3 mm on average compared to 0.9 mm for the MatriXX PT. Significance. We have experimentally verified the delivery of DCS-collimated fields using a clinical PBS system and commonly available dosimeters and have also identified potential weaknesses for dosimeters subject to steep dose gradients.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Dosimetric Comparison of Pencil Beam Scanning Proton Plans with Different Aperture Modes
    Yuan, Y.
    DeBlois, D.
    Chen, Y.
    Frame, C.
    Pang, D.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [32] Optimization of proton pencil beam positioning in collimated fields
    Behrends, Carina
    Baeumer, Christian
    Verbeek, Nico Gerd
    Wulff, Joerg
    Timmermann, Beate
    MEDICAL PHYSICS, 2023, 50 (04) : 2540 - 2551
  • [33] Clinical validation of Monte Carlo dose calculation for pencil beam scanning proton therapy.
    Widesott, L.
    Lorentini, S.
    Fracchiolla, F.
    Farace, P.
    Schwarz, M.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S45 - S46
  • [34] Validation of automated complex head and neck treatment planning with pencil beam scanning proton therapy
    Hedrick, Samantha Grace
    Petro, Scott
    Ward, Alex
    Morris, Bart
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (02):
  • [35] Conformal Pencil Beam Scanning Proton Therapy for Delivery of Flank Radiation in Children with Renal Tumors
    Hill-Kayser, C. E.
    Vogel, J.
    Li, Y.
    Lustig, R. A.
    Kurtz, G.
    LaRiviere, M. J.
    Cummings, E. R.
    Mattei, P.
    Balamuth, N.
    Bagatell, R.
    MacFarland, S.
    Evageliou, N.
    Tochner, Z. A.
    Balis, F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2022, 114 (03): : S71 - S72
  • [36] Validation and clinical implementation of an accurate Monte Carlo code for pencil beam scanning proton therapy
    Huang, Sheng
    Kang, Minglei
    Souris, Kevin
    Ainsley, Christopher
    Solberg, Timothy D.
    McDonough, James E.
    Simone, Charles B.
    Lin, Liyong
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (05): : 558 - 572
  • [37] Technical note: Delivery benefit and dosimetric implication of synchrotron-based proton pencil beam scanning using continuous scanning mode
    Liang, Xiaoying
    Beltran, Chris J.
    Liu, Chunbo
    Shen, Jiajian
    Li, Heng
    Furutani, Keith M.
    MEDICAL PHYSICS, 2023, 50 (08) : 5252 - 5261
  • [38] Pencil-beam scanning proton therapy for anal cancer: a dosimetric comparison with intensity-modulated radiotherapy
    Ojerholm, Eric
    Kirk, Maura L.
    Thompson, Reid F.
    Zhai, Huifang
    Metz, James M.
    Both, Stefan
    Ben-Josef, Edgar
    Plastaras, John P.
    ACTA ONCOLOGICA, 2015, 54 (08) : 1209 - 1217
  • [39] Pencil beam scanning proton therapy for treatment of the retroperitoneum after nephrectomy for Wilms tumor: A dosimetric comparison study
    Vogel, Jennifer
    Lin, Haibo
    Both, Stefan
    Tochner, Zelig
    Balis, Frank
    Hill-Kayser, Christine
    PEDIATRIC BLOOD & CANCER, 2017, 64 (01) : 39 - 45
  • [40] An approach for estimating dosimetric uncertainties in deformable dose accumulation in pencil beam scanning proton therapy for lung cancer
    Amstutz, Florian
    Nenoff, Lena
    Albertini, Francesca
    Ribeiro, Cassia O.
    Knopf, Antje C.
    Unkelbach, Jan
    Weber, Damien C.
    Lomax, Antony J.
    Zhang, Ye
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (10):