An approach for estimating dosimetric uncertainties in deformable dose accumulation in pencil beam scanning proton therapy for lung cancer

被引:17
|
作者
Amstutz, Florian [1 ,2 ]
Nenoff, Lena [1 ,2 ]
Albertini, Francesca [1 ]
Ribeiro, Cassia O. [3 ]
Knopf, Antje C. [3 ,4 ]
Unkelbach, Jan [5 ]
Weber, Damien C. [1 ,5 ,6 ]
Lomax, Antony J. [1 ,2 ]
Zhang, Ye [1 ]
机构
[1] Paul Scherrer Inst, Ctr Proton Therapy, Villigen, Switzerland
[2] Swiss Fed Inst Technol, Dept Phys, Zurich, Switzerland
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Radiat Oncol, Groningen, Netherlands
[4] Carl von Ossietzky Univ Oldenburg, Div Med Radiat Phys, Oldenburg, Germany
[5] Univ Hosp Zurich, Dept Radiat Oncol, Zurich, Switzerland
[6] Univ Hosp Bern, Dept Radiat Oncol, Bern, Switzerland
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2021年 / 66卷 / 10期
关键词
deformable image registration; uncertainties; proton therapy; dose accumulation; lung cancer; IMAGE REGISTRATION; ACCURACY; RADIOTHERAPY; INTERPLAY; IMPACT; DISTANCE; PHOTON; PLANS; TOOL;
D O I
10.1088/1361-6560/abf8f5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Deformable image registration (DIR) is an important component for dose accumulation and associated clinical outcome evaluation in radiotherapy. However, the resulting deformation vector field (DVF) is subject to unavoidable discrepancies when different algorithms are applied, leading to dosimetric uncertainties of the accumulated dose. We propose here an approach for proton therapy to estimate dosimetric uncertainties as a consequence of modeled or estimated DVF uncertainties. A patient-specific DVF uncertainty model was built on the first treatment fraction, by correlating the magnitude differences of five DIR results at each voxel to the magnitude of any single reference DIR. In the following fractions, only the reference DIR needs to be applied, and DVF geometric uncertainties were estimated by this model. The associated dosimetric uncertainties were then derived by considering the estimated geometric DVF uncertainty, the dose gradient of fractional recalculated dose distribution and the direction factor from the applied reference DIR of this fraction. This estimated dose uncertainty was respectively compared to the reference dose uncertainty when different DIRs were applied individually for each dose warping. This approach was validated on seven NSCLC patients, each with nine repeated CTs. The proposed model-based method is able to achieve dose uncertainty distribution on a conservative voxel-to-voxel comparison within +/- 5% of the prescribed dose to the 'reference' dosimetric uncertainty, for 77% of the voxels in the body and 66%-98% of voxels in investigated structures. We propose a method to estimate DIR induced uncertainties in dose accumulation for proton therapy of lung tumor treatments.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Dosimetric uncertainties in pencil beam proton therapy for breast cancer
    Tommasino, F.
    Lorentini, S.
    Schwarz, M.
    Fellin, F.
    Farace, P.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S68 - S68
  • [2] Pencil Beam Scanning:: a dynamical approach to proton therapy
    Sepulchre, R
    Gérard, M
    Marchand, B
    Prieels, D
    Bauvir, B
    [J]. IEEE INTERNATIONAL SYMPOSIUM ON BIO-INFORMATICS AND BIOMEDICAL ENGINEERING, PROCEEDINGS, 2000, : 370 - 375
  • [3] Dosimetric Comparison of Patient Alignment Techniques in Pencil Beam Scanning Proton Therapy for Prostate Cancer
    Remick, J.
    Snider, J. W., III
    Diwanji, T.
    Houser, T.
    Langner, U.
    Zhu, M.
    Bentzen, S. M.
    Feigenberg, S. J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E714 - E714
  • [4] Determination of surface dose in pencil beam scanning proton therapy
    Kern, A.
    Baeumer, C.
    Kroeninger, K.
    Mertens, L.
    Timmermann, B.
    Walbersloh, J.
    Wulff, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S483 - S483
  • [5] Determination of surface dose in pencil beam scanning proton therapy
    Kern, A.
    Baeumer, C.
    Kroeninger, K.
    Mertens, L.
    Timmermann, B.
    Walbersloh, J.
    Wulff, J.
    [J]. MEDICAL PHYSICS, 2020, 47 (05) : 2277 - 2288
  • [6] Dosimetric delivery validation of dynamically collimated pencil beam scanning proton therapy
    Nelson, Nicholas P.
    Culberson, Wesley S.
    Hyer, Daniel E.
    Geoghegan, Theodore J.
    Patwardhan, Kaustubh A.
    Smith, Blake R.
    Flynn, Ryan T.
    Yu, Jen
    Gutierrez, Alonso N.
    Hill, Patrick M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (05):
  • [7] Collimating individual beamlets in pencil beam scanning proton therapy, a dosimetric investigation
    Holmes, Jason
    Shen, Jiajian
    Patel, Samir H.
    Wong, William W.
    Foote, Robert L.
    Bues, Martin
    Liu, Wei
    [J]. FRONTIERS IN ONCOLOGY, 2022, 12
  • [8] Dosimetric Delivery Validation of Dynamically Collimated Pencil Beam Scanning Proton Therapy
    Nelson, N.
    Culberson, W.
    Hyer, D.
    Geoghegan, T.
    Patwardhan, K.
    Smith, B.
    Flynn, R.
    Yu, J.
    Gutierrez, A.
    Hill, P.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E509 - E510
  • [9] Impact of dose engine algorithm in pencil beam scanning proton therapy for breast cancer
    Tommasino, Francesco
    Fellin, Francesco
    Lorentini, Stefano
    Farace, Paolo
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 50 : 7 - 12
  • [10] Proton pencil beam scanning with motion emulated as spot shifts: dose reconstruction for lung cancer
    Damkjaer, S.
    Hoffmann, L.
    Moller, D. S.
    Petersen, J. B. B.
    Josipovic, M.
    Persson, G. F.
    af Rosenschold, P. Munck
    Poulsen, P. R.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S974 - S975