Dosimetric delivery validation of dynamically collimated pencil beam scanning proton therapy

被引:4
|
作者
Nelson, Nicholas P. [1 ]
Culberson, Wesley S. [1 ]
Hyer, Daniel E. [2 ]
Geoghegan, Theodore J. [2 ]
Patwardhan, Kaustubh A. [2 ]
Smith, Blake R. [2 ]
Flynn, Ryan T. [2 ]
Yu, Jen [3 ]
Gutierrez, Alonso N. [3 ]
Hill, Patrick M. [4 ]
机构
[1] Univ Wisconsin Madison, Sch Med & Publ Hlth, Dept Med Phys, 1111 Highland Ave, Madison, WI 53705 USA
[2] Univ Iowa Hosp & Clin, Dept Radiat Oncol, 200 Hawkins Dr, Iowa City, IA 52242 USA
[3] Baptist Hlth South Florida, Miami Canc Inst, Dept Radiat Oncol, 8900 N Kendall Dr, Miami, FL 33176 USA
[4] Univ Wisconsin Madison, Sch Med & Publ Hlth, Dept Human Oncol, 600 Highland Ave, Madison, WI 53792 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2023年 / 68卷 / 05期
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
proton therapy; collimation; Monte Carlo; dosimetry; IONIZATION-CHAMBER ARRAY; BRAIN-TUMORS; SPOT SIZE; QUALITY; SYSTEM; IMPACT;
D O I
10.1088/1361-6560/acb6cd
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Pencil beam scanning (PBS) proton therapy target dose conformity can be improved with energy layer-specific collimation. One such collimator is the dynamic collimation system (DCS), which consists of four nickel trimmer blades that intercept the scanning beam as it approaches the lateral extent of the target. While the dosimetric benefits of the DCS have been demonstrated through computational treatment planning studies, there has yet to be experimental verification of these benefits for composite multi-energy layer fields. The objective of this work is to dosimetrically characterize and experimentally validate the delivery of dynamically collimated proton therapy with the DCS equipped to a clinical PBS system. Approach. Optimized single field, uniform dose treatment plans for 3 x 3 x 3 cm(3) target volumes were generated using Monte Carlo dose calculations with depths ranging from 5 to 15 cm, trimmer-to-surface distances ranging from 5 to 18.15 cm, with and without a 4 cm thick polyethylene range shifter. Treatment plans were then delivered to a water phantom using a prototype DCS and an IBA dedicated nozzle system and measured with a Zebra multilayer ionization chamber, a MatriXX PT ionization chamber array, and Gafchromic (TM) EBT3 film. Main results. For measurements made within the SOBPs, average 2D gamma pass rates exceeded 98.5% for the MatriXX PT and 96.5% for film at the 2%/2 mm criterion across all measured uncollimated and collimated plans, respectively. For verification of the penumbra width reduction with collimation, film agreed with Monte Carlo with differences within 0.3 mm on average compared to 0.9 mm for the MatriXX PT. Significance. We have experimentally verified the delivery of DCS-collimated fields using a clinical PBS system and commonly available dosimeters and have also identified potential weaknesses for dosimeters subject to steep dose gradients.
引用
下载
收藏
页数:11
相关论文
共 50 条
  • [1] Dosimetric Delivery Validation of Dynamically Collimated Pencil Beam Scanning Proton Therapy
    Nelson, N.
    Culberson, W.
    Hyer, D.
    Geoghegan, T.
    Patwardhan, K.
    Smith, B.
    Flynn, R.
    Yu, J.
    Gutierrez, A.
    Hill, P.
    MEDICAL PHYSICS, 2022, 49 (06) : E509 - E510
  • [2] Dynamically Collimated Spatially Fractionated (GRID) Pencil Beam Scanning Proton Therapy
    Smith, B.
    Allen, B.
    Hyer, D.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [3] Integration and dosimetric validation of a dynamic collimation system for pencil beam scanning proton therapy
    Nelson, Nicholas P.
    Culberson, Wesley S.
    Hyer, Daniel E.
    Geoghegan, Theodore J.
    Patwardhan, Kaustubh A.
    Smith, Blake R.
    Flynn, Ryan T.
    Gutierrez, Alonso N.
    Boland, Thibault
    Hill, Patrick M.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2023, 9 (06)
  • [4] Validation of a Pencil Beam Model for Collimated Proton Therapy Dose Calculations
    Bennett, L.
    Smith, B.
    Wang, D.
    Flynn, R.
    Hyer, D.
    MEDICAL PHYSICS, 2019, 46 (06) : E167 - E167
  • [5] Determining the Optimal Collimator Position for Collimated Pencil Beam Scanning Proton Therapy
    Wang, D.
    Smith, B.
    Hill, P.
    Gelover, E.
    Flynn, R.
    Hyer, D.
    MEDICAL PHYSICS, 2014, 41 (06) : 550 - 551
  • [6] Biophysical characterization of collimated and uncollimated fields in pencil beam scanning proton therapy
    Nabha, Racell
    De Saint-Hubert, Marijke
    Marichal, Joachim
    Esser, Johannes
    Van Hoey, Olivier
    Baeumer, Christian
    Verbeek, Nico
    Struelens, Lara
    Sterpin, Edmond
    Tabury, Kevin
    Marek, Lukas
    Granja, Carlos
    Timmermann, Beate
    Vanhavere, Filip
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (06):
  • [7] Collimating individual beamlets in pencil beam scanning proton therapy, a dosimetric investigation
    Holmes, Jason
    Shen, Jiajian
    Patel, Samir H.
    Wong, William W.
    Foote, Robert L.
    Bues, Martin
    Liu, Wei
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [8] Dosimetric Impact of CT Metal Artifacts on Proton Pencil-Beam Scanning Delivery
    Verburg, J.
    Joshi, M.
    Bazalova, M.
    Madden, T.
    Kooy, H.
    Seco, J.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [9] A simulator of proton pencil beam scanning delivery
    Poulsen, P. R.
    Nystrom, H.
    Skyt, P. S.
    Jensen, M. F.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S124 - S125
  • [10] Innovations and the Use of Collimators in the Delivery of Pencil Beam Scanning Proton Therapy
    Hyer, Daniel E.
    Bennett, Laura C.
    Geoghegan, Theodore J.
    Bues, Martin
    Smith, Blake R.
    INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2021, 8 (01) : 73 - 83