Biophysical characterization of collimated and uncollimated fields in pencil beam scanning proton therapy

被引:0
|
作者
Nabha, Racell [1 ,2 ]
De Saint-Hubert, Marijke [1 ]
Marichal, Joachim [3 ]
Esser, Johannes [4 ,5 ]
Van Hoey, Olivier [1 ]
Baeumer, Christian [4 ,5 ,6 ,7 ]
Verbeek, Nico [4 ,5 ]
Struelens, Lara [1 ]
Sterpin, Edmond [2 ,8 ]
Tabury, Kevin [9 ]
Marek, Lukas [10 ]
Granja, Carlos [10 ]
Timmermann, Beate [4 ,5 ,7 ,11 ]
Vanhavere, Filip [1 ,2 ]
机构
[1] Belgian Nucl Res Ctr SCK CEN, Radiat Protect Dosimetry & Calibrat Expert Grp, Mol, Belgium
[2] Katholieke Univ Leuven, Dept Oncol, Lab Expt Radiotherapy, Leuven, Belgium
[3] Katholieke Univ Leuven, Fac Sci, Leuven, Belgium
[4] West German Proton Therapy Ctr Essen, Essen, Germany
[5] Univ Hosp Essen, West German Canc Ctr WTZ, Essen, Germany
[6] TU Dortmund Univ, Dept Phys, Dortmund, Germany
[7] German Canc Consortium DKTK, Heidelberg, Germany
[8] UCLouvain, Inst Rech Expt & Clin, MIRO Lab, Brussels, Belgium
[9] Belgian Nucl Res Ctr SCK CEN, Radiobiol Unit, Mol, Belgium
[10] ADVACAM, Prague, Czech Republic
[11] Univ Hosp Essen, Dept Particle Therapy, Essen, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2023年 / 68卷 / 06期
关键词
proton therapy; pencil beam scanning; DNA damage; Timepix; aperture; collimation; RELATIVE BIOLOGICAL EFFECTIVENESS; MONTE-CARLO; PIXEL DETECTOR; SIMULATION; TIMEPIX; TRACK; TOPAS;
D O I
10.1088/1361-6560/acbe8d
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. The lateral dose fall-off in proton pencil beam scanning (PBS) technique remains the preferred choice for sparing adjacent organs at risk as opposed to the distal edge due to the proton range uncertainties and potentially high relative biological effectiveness. However, because of the substantial spot size along with the scattering in the air and in the patient, the lateral penumbra in PBS can be degraded. Combining PBS with an aperture can result in a sharper dose fall-off, particularly for shallow targets. Approach. The aim of this work was to characterize the radiation fields produced by collimated and uncollimated 100 and 140 MeV proton beams, using Monte Carlo simulations and measurements with a MiniPIX-Timepix detector. The dose and the linear energy transfer (LET) were then coupled with published in silico biophysical models to elucidate the potential biological effects of collimated and uncollimated fields. Main results. Combining an aperture with PBS reduced the absorbed dose in the lateral fall-off and out-of-field by 60%. However, the results also showed that the absolute frequency-averaged LET (LETF) values increased by a maximum of 3.5 keV mu m(-1) in collimated relative to uncollimated fields, while the dose-averaged LET (LETD) increased by a maximum of 7 keV mu m(-1). Despite the higher LET values produced by collimated fields, the predicted DNA damage yields remained lower, owing to the large dose reduction. Significance. This work demonstrated the dosimetric advantages of combining an aperture with PBS coupled with lower DNA damage induction. A methodology for calculating dose in water derived from measurements with a silicon-based detector was also presented. This work is the first to demonstrate experimentally the increase in LET caused by combining PBS with aperture, and to assess the potential DNA damage which is the initial step in the cascade of events leading to the majority of radiation-induced biological effects.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Dynamically Collimated Spatially Fractionated (GRID) Pencil Beam Scanning Proton Therapy
    Smith, B.
    Allen, B.
    Hyer, D.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [2] Dosimetric Delivery Validation of Dynamically Collimated Pencil Beam Scanning Proton Therapy
    Nelson, N.
    Culberson, W.
    Hyer, D.
    Geoghegan, T.
    Patwardhan, K.
    Smith, B.
    Flynn, R.
    Yu, J.
    Gutierrez, A.
    Hill, P.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E509 - E510
  • [3] Dosimetric delivery validation of dynamically collimated pencil beam scanning proton therapy
    Nelson, Nicholas P.
    Culberson, Wesley S.
    Hyer, Daniel E.
    Geoghegan, Theodore J.
    Patwardhan, Kaustubh A.
    Smith, Blake R.
    Flynn, Ryan T.
    Yu, Jen
    Gutierrez, Alonso N.
    Hill, Patrick M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (05):
  • [4] Optimization of proton pencil beam positioning in collimated fields
    Behrends, Carina
    Baeumer, Christian
    Verbeek, Nico Gerd
    Wulff, Joerg
    Timmermann, Beate
    [J]. MEDICAL PHYSICS, 2023, 50 (04) : 2540 - 2551
  • [5] Determining the Optimal Collimator Position for Collimated Pencil Beam Scanning Proton Therapy
    Wang, D.
    Smith, B.
    Hill, P.
    Gelover, E.
    Flynn, R.
    Hyer, D.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 550 - 551
  • [6] Parametric characterization of penumbra reduction for aperture-collimated pencil beam scanning (PBS) proton therapy
    Maes, Dominic
    Regmi, Rajesh
    Taddei, Phillip
    Bloch, Charles
    Bowen, Steven
    Nevitt, Alexander
    Leuro, Erick
    Wong, Tony
    Rosenfeld, Anatoly
    Saini, Jatinder
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (03):
  • [7] Tuning An Analytical Proton Therapy Dose Calculation Algorithm for Penumbra Agreement in Collimated Pencil Beam Scanning Proton Therapy
    Bennett, L.
    Erhart, K.
    Nelson, N.
    Yu, J.
    Gutierrez, A.
    Rana, S.
    Smith, B.
    Hill, P.
    Hyer, D.
    Geoghegan, T.
    Patwardhan, K.
    Culberson, W.
    Flynn, R.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E424 - E424
  • [8] Comparison between the lateral penumbra of a collimated double-scattered beam and uncollimated scanning beam in proton radiotherapy
    Safai, Sairos
    Bortfeld, Thomas
    Engelsman, Martijn
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (06): : 1729 - 1750
  • [9] Introduction to Pencil Beam Scanning Proton Therapy
    Zhu, M.
    Mossahebi, S.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E275 - E276
  • [10] Utilizing collimated aperture with proton pencil beam scanning (PBS) for stereotactic radiotherapy
    Chou, Chen-Yu
    Tsai, Tsung-Shiau
    Huang, Hsiao-Chieh
    Wang, Jiun-Jie
    Lee, Shen-Hao
    Hsu, Shih-Ming
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (07):