Failure experiment on CFRP-strengthened prestressed concrete cylinder pipe with broken wires

被引:20
|
作者
Zhai, Kejie [1 ,2 ]
Fang, Hongyuan [1 ]
Li, Bin [1 ]
Guo, Chengchao [2 ]
Yang, Kangjian [1 ]
Du, Xueming [1 ]
Du, Mingrui [1 ]
Wang, Niannian [1 ]
机构
[1] Zhengzhou Univ, Yellow River Lab, Zhengzhou 450001, Peoples R China
[2] Sun Yat Sen Univ, Sch Civil Engn, Guangzhou 510275, Peoples R China
基金
中国国家自然科学基金;
关键词
Prestressed concrete cylinder pipe (PCCP); Broken wires; Carbon fiber reinforced polymer (CFRP); Strain gauging; Failure experiment; COATING DELAMINATION; RADIAL TENSION; PERFORMANCE; PCCP;
D O I
10.1016/j.tust.2023.105032
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The prestressed concrete cylinder pipe (PCCP) has been used widely in hydraulic engineering. However, due to hydrogen embrittlement and corrosion, the prestressing wires in PCCP can break and cause pipe failure. In this study, a retrofitting technique of using externally bonded carbon fiber reinforced polymer (CFRP) to repair PCCP was proposed. The technique is particularly useful when shutting down water is not possible. The proposed strategy was evaluated by using a full-scale PCCP with a 2.8 m inside diameter loaded with internal water pressure. First, the PCCP strains before and after repair were compared under different internal pressures. In the presence of CFRP, the strains near the broken wires significantly decreased under the same internal pressure, and the carrying capacity of the PCCP increased. PCCPs with 13 %, 15 %, and 18 % wire breakage ratios were then evaluated and compared. The strain in each material increased with increasing wire breakage ratio, and the maximum strain in CFRP was observed at the location of wire breakage. Considering the PCCP with 18 % wire breakage ratio, the section 2300 mm from the pipe end was in the linear state under an internal pressure of 0-0.9 MPa, and the PCCP reached its serviceability and elastic limit states when the internal pressure increased to about 1.0 MPa and 1.2 MPa, respectively. Finally, when the internal water pressure was increased to 1.27 MPa, which was higher than the internal design pressure of 1.12 MPa, the PCCP failed due to the rupture of CFRP.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Prestressed steel wires impact on axial bearing capacity of ultra-large section jacking prestressed concrete cylinder pipe (JPCCP): Field experiment and simulation
    Zhou, Hao
    Huang, Sheng
    Ma, Baosong
    Zhao, Yahong
    Tan, Xuhong
    Zhang, Haifeng
    ENGINEERING FAILURE ANALYSIS, 2025, 167
  • [42] Ductility and cracking behavior of prestressed concrete beams strengthened with prestressed CFRP sheets
    Kim, Yail J.
    Shi, Chen
    Green, Mark F.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2008, 12 (03) : 274 - 283
  • [43] Effect of the location of broken wire wraps on the failure pressure of prestressed concrete cylinder pipes
    Hajali, Masood
    Alavinasab, Ali
    Shdid, Caesar Abi
    STRUCTURAL CONCRETE, 2015, 16 (02) : 297 - 303
  • [44] Design method for concrete columns strengthened with prestressed CFRP sheets
    Cheng, Donghui
    Yang, Yanhong
    CONSTRUCTION AND BUILDING MATERIALS, 2017, 151 : 331 - 344
  • [45] Concrete beams strengthened with prestressed near surface mounted CFRP
    Nordin, H
    Täljsten, B
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2006, 10 (01) : 60 - 68
  • [46] Experimental studies of concrete beams strengthened with prestressed CFRP laminates
    Xue, Weichen
    Tan, Yuan
    Zeng, Lei
    PCI JOURNAL, 2008, 53 (05): : 70 - 85
  • [47] A YOLOX-Based Automatic Monitoring Approach of Broken Wires in Prestressed Concrete Cylinder Pipe Using Fiber-Optic Distributed Acoustic Sensors
    Ma, Baolong
    Gao, Ruizhen
    Zhang, Jingjun
    Zhu, Xinmin
    SENSORS, 2023, 23 (04)
  • [48] Experimental and numerical study on CFRP-lined prestressed concrete cylinder pipe under internal pressure
    Hu, He
    Dou, Tiesheng
    Niu, Fujun
    Zhang, Heng
    Su, Wenji
    ENGINEERING STRUCTURES, 2019, 190 : 480 - 492
  • [49] Performance of concrete beam strengthened with prestressed sprial steel wires
    Yahong D.
    Meixiang Z.
    Xianggang Z.
    Journal of Engineering Science and Technology Review, 2019, 12 (05) : 31 - 35
  • [50] A Prestressed Concrete Cylinder Pipe Broken Wire Detection Algorithm Based on Improved YOLOv5
    Li, Haoze
    Gao, Ruizhen
    Sun, Fang
    Wang, Yv
    Ma, Baolong
    SENSORS, 2025, 25 (03)