Failure experiment on CFRP-strengthened prestressed concrete cylinder pipe with broken wires

被引:20
|
作者
Zhai, Kejie [1 ,2 ]
Fang, Hongyuan [1 ]
Li, Bin [1 ]
Guo, Chengchao [2 ]
Yang, Kangjian [1 ]
Du, Xueming [1 ]
Du, Mingrui [1 ]
Wang, Niannian [1 ]
机构
[1] Zhengzhou Univ, Yellow River Lab, Zhengzhou 450001, Peoples R China
[2] Sun Yat Sen Univ, Sch Civil Engn, Guangzhou 510275, Peoples R China
基金
中国国家自然科学基金;
关键词
Prestressed concrete cylinder pipe (PCCP); Broken wires; Carbon fiber reinforced polymer (CFRP); Strain gauging; Failure experiment; COATING DELAMINATION; RADIAL TENSION; PERFORMANCE; PCCP;
D O I
10.1016/j.tust.2023.105032
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The prestressed concrete cylinder pipe (PCCP) has been used widely in hydraulic engineering. However, due to hydrogen embrittlement and corrosion, the prestressing wires in PCCP can break and cause pipe failure. In this study, a retrofitting technique of using externally bonded carbon fiber reinforced polymer (CFRP) to repair PCCP was proposed. The technique is particularly useful when shutting down water is not possible. The proposed strategy was evaluated by using a full-scale PCCP with a 2.8 m inside diameter loaded with internal water pressure. First, the PCCP strains before and after repair were compared under different internal pressures. In the presence of CFRP, the strains near the broken wires significantly decreased under the same internal pressure, and the carrying capacity of the PCCP increased. PCCPs with 13 %, 15 %, and 18 % wire breakage ratios were then evaluated and compared. The strain in each material increased with increasing wire breakage ratio, and the maximum strain in CFRP was observed at the location of wire breakage. Considering the PCCP with 18 % wire breakage ratio, the section 2300 mm from the pipe end was in the linear state under an internal pressure of 0-0.9 MPa, and the PCCP reached its serviceability and elastic limit states when the internal pressure increased to about 1.0 MPa and 1.2 MPa, respectively. Finally, when the internal water pressure was increased to 1.27 MPa, which was higher than the internal design pressure of 1.12 MPa, the PCCP failed due to the rupture of CFRP.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Effect of Partial Unbonding on Prestressed Near-Surface-Mounted CFRP-Strengthened Concrete T-Beams
    Choi, Han T.
    West, Jeffrey S.
    Soudki, Khaled A.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2011, 15 (01) : 93 - 102
  • [22] Research on broken wire identification method based on PoolConv for prestressed concrete cylinder pipe
    Wang, Yu
    Sun, Fang
    Gao, Ruizhen
    Ma, Baolong
    Li, Haoze
    SIGNAL IMAGE AND VIDEO PROCESSING, 2024, 18 (8-9) : 6029 - 6039
  • [23] Performance of preloaded CFRP-strengthened fiber reinforced concrete beams
    Helal, Kareem
    Yehia, Sherif
    Hawileh, Rami
    Abdalla, Jamal
    COMPOSITE STRUCTURES, 2020, 244
  • [24] Flexural behavior of CFRP-strengthened and corroded reinforced concrete beams
    Hussein, M.
    CONCRETE SOLUTIONS, 2012, : 673 - 680
  • [25] Overload test and failure mechanism analysis of prestressed concrete cylinder pipe
    Hu, Shaowei
    Liu, Xiaoxin
    Shuili Fadian Xuebao/Journal of Hydroelectric Engineering, 2012, 31 (01): : 103 - 107
  • [26] Strut Deformation in CFRP-Strengthened Reinforced Concrete Deep Beams
    Panjehpour, Mohammad
    Chai, Hwa Kian
    Voo, Yen Lei
    SCIENTIFIC WORLD JOURNAL, 2014,
  • [27] Serviceability assessment of prestressed concrete cylinder pipes with broken wires: Analytical solution and numerical simulation
    Zhai, Kejie
    Wang, Fuming
    Fang, Hongyuan
    Ni, Pengpeng
    Ji, Xinbo
    Guo, Chengchao
    Hu, Shaowei
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2022, 126
  • [28] Performance of concrete beams strengthened with prestressed CFRP plates
    Chen Hua
    Deng Langni
    Zhang Peng
    MATERIALS ENGINEERING FOR ADVANCED TECHNOLOGIES, PTS 1 AND 2, 2011, 480-481 : 170 - 174
  • [29] Performance of CFRP-strengthened concrete beams fastened with distributed CFRP dowel and fiber anchors
    Zaki, Mohammed A.
    Rasheed, Hayder A.
    Alkhrdaji, Tarek
    COMPOSITES PART B-ENGINEERING, 2019, 176
  • [30] Durability of Broken Concrete Specimens Strengthened with CFRP Sheets
    Lee, Ming-Ju
    Lee, Ming-Gin
    Huang, Yi-Shuo
    Liang, Yang-hsin
    MULTI-FUNCTIONAL MATERIALS AND STRUCTURES III, PTS 1 AND 2, 2010, 123-125 : 1119 - +