A study of Bayesian deep network uncertainty and its application to synthetic CT generation for MR-only radiotherapy treatment planning

被引:3
|
作者
Law, Max Wai-Kong [1 ,3 ]
Tse, Mei-Yan [1 ]
Ho, Leon Chin-Chak [1 ]
Lau, Ka-Ki [1 ]
Wong, Oi Lei [2 ]
Yuan, Jing [2 ]
Cheung, Kin Yin [1 ]
Yu, Siu Ki [1 ]
机构
[1] Hong Kong Sanat & Hosp, Med Phys Dept, Hong Kong, Peoples R China
[2] Hong Kong Sanat & Hosp, Res Dept, Hong Kong, Peoples R China
[3] Hong Kong Sanat & Hosp, Eastern Med Ctr, Med Phys Dept, Hong Kong, Peoples R China
关键词
Bayesian; MR-Only planning; Synthetic CT; CONVOLUTIONAL NEURAL-NETWORK; THERAPY; IMAGE; SIMULATION;
D O I
10.1002/mp.16666
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundThe use of synthetic computed tomography (CT) for radiotherapy treatment planning has received considerable attention because of the absence of ionizing radiation and close spatial correspondence to source magnetic resonance (MR) images, which have excellent tissue contrast. However, in an MR-only environment, little effort has been made to examine the quality of synthetic CT images without using the original CT images.PurposeTo estimate synthetic CT quality without referring to original CT images, this study established the relationship between synthetic CT uncertainty and Bayesian uncertainty, and proposed a new Bayesian deep network for generating synthetic CT images and estimating synthetic CT uncertainty for MR-only radiotherapy treatment planning.Methods and MaterialsA novel deep Bayesian network was formulated using probabilistic network weights. Two mathematical expressions were proposed to quantify the Bayesian uncertainty of the network and synthetic CT uncertainty, which was closely related to the mean absolute error (MAE) in Hounsfield Unit (HU) of synthetic CT. These uncertainties were examined to demonstrate the accuracy of representing the synthetic CT uncertainty using a Bayesian counterpart. We developed a hybrid Bayesian architecture and a new data normalization scheme, enabling the Bayesian network to generate both accurate synthetic CT and reliable uncertainty information when probabilistic weights were applied. The proposed method was evaluated in 59 patients (13/12/32/2 for training/validation/testing/uncertainty visualization) diagnosed with prostate cancer, who underwent same-day pelvic CT- and MR-acquisitions. To assess the relationship between Bayesian and synthetic CT uncertainties, linear and non-linear correlation coefficients were calculated on per-voxel, per-tissue, and per-patient bases. For accessing the accuracy of the CT number and dosimetric accuracy, the proposed method was compared with a commercially available atlas-based method (MRCAT) and a U-Net conditional-generative adversarial network (UcGAN).ResultsThe proposed model exhibited 44.33 MAE, outperforming UcGAN 52.51 and MRCAT 54.87. The gamma rate (2%/2 mm dose difference/distance to agreement) of the proposed model was 98.68%, comparable to that of UcGAN (98.60%) and MRCAT (98.56%). The per-patient and per-tissue linear correlation coefficients between the Bayesian and synthetic CT uncertainties ranged from 0.53 to 0.83, implying a moderate to strong linear correlation. Per-voxel correlation coefficients varied from -0.13 to 0.67 depending on the regions-of-interest evaluated, indicating tissue-dependent correlation. The R2 value for estimating MAE solely using Bayesian uncertainty was 0.98, suggesting that the uncertainty of the proposed model was an ideal candidate for predicting synthetic CT error, without referring to the original CT.ConclusionThis study established a relationship between the Bayesian model uncertainty and synthetic CT uncertainty. A novel Bayesian deep network was proposed to generate a synthetic CT and estimate its uncertainty. Various metrics were used to thoroughly examine the relationship between the uncertainties of the proposed Bayesian model and the generated synthetic CT. Compared with existing approaches, the proposed model showed comparable CT number and dosimetric accuracies. The experiments showed that the proposed Bayesian model was capable of producing accurate synthetic CT, and was an effective indicator of the uncertainty and error associated with synthetic CT in MR-only workflows.
引用
收藏
页码:1244 / 1262
页数:19
相关论文
共 50 条
  • [41] Dosimetric Evaluation of Multi-sequence MR Image-based Synthetic CT Generation for Head and Neck MR-only Radiotherapy
    Li, Y.
    Qi, M.
    Wu, A.
    Zhou, L.
    Deng, X.
    Song, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E291 - E292
  • [42] Does MR-only treatment planning live up to its expectations?
    Nyholm, T.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S92 - S92
  • [43] SARU: A self-attention ResUNet to generate synthetic CT images for MR-only BNCT treatment planning
    Zhao, Sheng
    Geng, Changran
    Guo, Chang
    Tian, Feng
    Tang, Xiaobin
    MEDICAL PHYSICS, 2023, 50 (01) : 117 - 127
  • [44] Transfer Learning-based synthetic CT generation for MR-only proton therapy planning in children with pelvic sarcomas
    Wang, Chuang
    Uh, Jinsoo
    He, Xiuxiu
    Hua, Chia-Ho
    Acharya, Sahaja
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [45] Deep learning-based synthetic CT generation for MR-only radiotherapy of prostate cancer patients with 0.35T MRI linear accelerator
    Farjam, Reza
    Nagar, Himanshu
    Kathy Zhou, Xi
    Ouellette, David
    Chiara Formenti, Silvia
    DeWyngaert, J. Keith
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (08): : 93 - 104
  • [46] Effect of synthetic CT on dose-derived toxicity predictors for MR-only prostate radiotherapy
    Thomas, Christopher
    Dregely, Isabel
    Oksuz, Ilkay
    Guerrero Urbano, Teresa
    Greener, Tony
    King, Andrew P.
    Barrington, Sally F.
    BJR OPEN, 2024, 6 (01):
  • [47] Dosimetric Evaluation of Midposition PseudoCT for MR-only Lung Radiotherapy Treatment planning.
    Freedman, J.
    Bainbridge, H.
    Wetscherek, A.
    Collins, D.
    Nill, S.
    Dunlop, A.
    Kachelriess, M.
    Leach, M.
    McDonald, F.
    Oelfke, U.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S526 - S527
  • [48] Generation of synthetic megavoltage CT for MRI-only radiotherapy treatment planning using a 3D deep convolutional neural network
    Scholey, Jessica E.
    Rajagopal, Abhejit
    Vasquez, Elena Grace
    Sudhyadhom, Atchar
    Larson, Peder Eric Zufall
    MEDICAL PHYSICS, 2022, 49 (10) : 6622 - 6634
  • [49] Dosimetric evaluation of MR-derived synthetic-CTs for MR-only proton treatment planning
    Nunez, David Aramburu
    Fontenla, Sandra
    Rydquist, Lauren
    Del Rosario, Gabriely
    Han, Zhiqiang
    Chen, Chin-Cheng
    Mah, Dennis
    Tyagi, Neelam
    MEDICAL DOSIMETRY, 2020, 45 (03) : 264 - 270
  • [50] Dosimetric Evaluation of MR-Derived Synthetic-CTs for MR-Only Proton Treatment Planning
    Nunez, D. Aramburu
    Fontenla, S.
    Rydquist, L.
    Del Rosario, G.
    Han, Z.
    Chen, C.
    Hunt, M.
    Mah, D.
    Tyagi, N.
    MEDICAL PHYSICS, 2018, 45 (06) : E468 - E468