A study of Bayesian deep network uncertainty and its application to synthetic CT generation for MR-only radiotherapy treatment planning

被引:3
|
作者
Law, Max Wai-Kong [1 ,3 ]
Tse, Mei-Yan [1 ]
Ho, Leon Chin-Chak [1 ]
Lau, Ka-Ki [1 ]
Wong, Oi Lei [2 ]
Yuan, Jing [2 ]
Cheung, Kin Yin [1 ]
Yu, Siu Ki [1 ]
机构
[1] Hong Kong Sanat & Hosp, Med Phys Dept, Hong Kong, Peoples R China
[2] Hong Kong Sanat & Hosp, Res Dept, Hong Kong, Peoples R China
[3] Hong Kong Sanat & Hosp, Eastern Med Ctr, Med Phys Dept, Hong Kong, Peoples R China
关键词
Bayesian; MR-Only planning; Synthetic CT; CONVOLUTIONAL NEURAL-NETWORK; THERAPY; IMAGE; SIMULATION;
D O I
10.1002/mp.16666
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundThe use of synthetic computed tomography (CT) for radiotherapy treatment planning has received considerable attention because of the absence of ionizing radiation and close spatial correspondence to source magnetic resonance (MR) images, which have excellent tissue contrast. However, in an MR-only environment, little effort has been made to examine the quality of synthetic CT images without using the original CT images.PurposeTo estimate synthetic CT quality without referring to original CT images, this study established the relationship between synthetic CT uncertainty and Bayesian uncertainty, and proposed a new Bayesian deep network for generating synthetic CT images and estimating synthetic CT uncertainty for MR-only radiotherapy treatment planning.Methods and MaterialsA novel deep Bayesian network was formulated using probabilistic network weights. Two mathematical expressions were proposed to quantify the Bayesian uncertainty of the network and synthetic CT uncertainty, which was closely related to the mean absolute error (MAE) in Hounsfield Unit (HU) of synthetic CT. These uncertainties were examined to demonstrate the accuracy of representing the synthetic CT uncertainty using a Bayesian counterpart. We developed a hybrid Bayesian architecture and a new data normalization scheme, enabling the Bayesian network to generate both accurate synthetic CT and reliable uncertainty information when probabilistic weights were applied. The proposed method was evaluated in 59 patients (13/12/32/2 for training/validation/testing/uncertainty visualization) diagnosed with prostate cancer, who underwent same-day pelvic CT- and MR-acquisitions. To assess the relationship between Bayesian and synthetic CT uncertainties, linear and non-linear correlation coefficients were calculated on per-voxel, per-tissue, and per-patient bases. For accessing the accuracy of the CT number and dosimetric accuracy, the proposed method was compared with a commercially available atlas-based method (MRCAT) and a U-Net conditional-generative adversarial network (UcGAN).ResultsThe proposed model exhibited 44.33 MAE, outperforming UcGAN 52.51 and MRCAT 54.87. The gamma rate (2%/2 mm dose difference/distance to agreement) of the proposed model was 98.68%, comparable to that of UcGAN (98.60%) and MRCAT (98.56%). The per-patient and per-tissue linear correlation coefficients between the Bayesian and synthetic CT uncertainties ranged from 0.53 to 0.83, implying a moderate to strong linear correlation. Per-voxel correlation coefficients varied from -0.13 to 0.67 depending on the regions-of-interest evaluated, indicating tissue-dependent correlation. The R2 value for estimating MAE solely using Bayesian uncertainty was 0.98, suggesting that the uncertainty of the proposed model was an ideal candidate for predicting synthetic CT error, without referring to the original CT.ConclusionThis study established a relationship between the Bayesian model uncertainty and synthetic CT uncertainty. A novel Bayesian deep network was proposed to generate a synthetic CT and estimate its uncertainty. Various metrics were used to thoroughly examine the relationship between the uncertainties of the proposed Bayesian model and the generated synthetic CT. Compared with existing approaches, the proposed model showed comparable CT number and dosimetric accuracies. The experiments showed that the proposed Bayesian model was capable of producing accurate synthetic CT, and was an effective indicator of the uncertainty and error associated with synthetic CT in MR-only workflows.
引用
收藏
页码:1244 / 1262
页数:19
相关论文
共 50 条
  • [31] A combined automatic MR OAR contouring and synthetic CT solution for prostate MR-only radiotherapy
    Wyatt, Jonathan J.
    Kaushik, Sandeep
    Cozzini, Cristina
    Kolozsvari, Bernadett
    Deak-Karancsi, Borbala
    Pearson, Rachel A.
    Petit, Steven
    Capala, Marta
    Hernandez-Tamames, Juan A.
    Hideghety, Katalin
    Maxwell, Ross J.
    Rusko, Laszlo
    Wiesinger, Florian
    McCallum, Hazel M.
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3144 - S3147
  • [32] Deep Learning-Based Synthetic CT Generation for MR-Only Adaptive Radiation Therapy On MR-Linacs
    Hunt, B.
    Zaki, B.
    Russo, G.
    Asher, G.
    Gill, G.
    Thomas, C.
    Prioleau, T.
    Gladstone, D.
    Pogue, B.
    Zhang, R.
    MEDICAL PHYSICS, 2022, 49 (06) : E760 - E761
  • [33] Deep Learning-Based Synthetic CT Generation for MR-Only Adaptive Radiation Therapy on MR-Linacs
    Hunt, B.
    Zaki, B.
    Russo, G. A.
    Gill, G. S.
    Asher, G. L.
    Prioleau, T.
    Gladstone, D. J.
    Pogue, B. W.
    Zhang, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2022, 114 (03): : E584 - E584
  • [34] Dosimetric evaluation of an atlas-based synthetic CT generation approach for MR-only radiotherapy of pelvis anatomy
    Farjam, Reza
    Tyag, Neelam
    Deasy, Joseph O.
    Hun, Margie A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (01): : 101 - 109
  • [35] Comparison of four synthetic CT generators for brain and prostate MR-only workflow in radiotherapy
    Autret, Damien
    Guillerminet, Camille
    Roussel, Alban
    Cossec-Kerloc'h, Erwan
    Dufreneix, Stephane
    RADIATION ONCOLOGY, 2023, 18 (01)
  • [36] Feasibility of Synthetic CT Generated From Multi-Sequence MR Images Using An Adversarial Network for MR-Only Radiotherapy
    Koike, Y.
    Akino, Y.
    Sumida, I.
    Shiomi, H.
    Mizuno, H.
    Yagi, M.
    Isohashi, F.
    Seo, Y.
    Suzuki, O.
    Ogawa, K.
    MEDICAL PHYSICS, 2019, 46 (06) : E185 - E185
  • [37] Automated hallucination detection for synthetic CT images used in MR-only radiotherapy workflows
    Parchur, Abdul K.
    Zarenia, Mohammad
    Gage, Colette
    Paulson, Eric S.
    Ahunbay, Ergun
    PHYSICS IN MEDICINE AND BIOLOGY, 2025, 70 (05):
  • [38] Comparison of four synthetic CT generators for brain and prostate MR-only workflow in radiotherapy
    Damien Autret
    Camille Guillerminet
    Alban Roussel
    Erwan Cossec-Kerloc’h
    Stéphane Dufreneix
    Radiation Oncology, 18 (1)
  • [39] Evaluation of a DL based synthetic CT algorithm for pelvis and brain MR-Only radiotherapy
    Badey, Aurelien
    Jaegle, Enric
    Biarnes, Maria-Elena Alayrach
    Martinez, Paul
    Lauzin, Yann
    Mazars, Pauline
    Zinutti, Marianne
    Saadi, Oussama
    Le Brun, Hugo
    Bodez, Veronique
    Vieillevigne, Laure
    Khamphan, Catherine
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3961 - S3963
  • [40] Does dose calculation algorithm affect the dosimetric accuracy of synthetic CT for MR-only radiotherapy planning in brain tumors?
    Lui, Jeffrey C. F.
    Lee, Francis K. H.
    Law, C. C.
    Chow, James C. H.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2025,