A study of Bayesian deep network uncertainty and its application to synthetic CT generation for MR-only radiotherapy treatment planning

被引:3
|
作者
Law, Max Wai-Kong [1 ,3 ]
Tse, Mei-Yan [1 ]
Ho, Leon Chin-Chak [1 ]
Lau, Ka-Ki [1 ]
Wong, Oi Lei [2 ]
Yuan, Jing [2 ]
Cheung, Kin Yin [1 ]
Yu, Siu Ki [1 ]
机构
[1] Hong Kong Sanat & Hosp, Med Phys Dept, Hong Kong, Peoples R China
[2] Hong Kong Sanat & Hosp, Res Dept, Hong Kong, Peoples R China
[3] Hong Kong Sanat & Hosp, Eastern Med Ctr, Med Phys Dept, Hong Kong, Peoples R China
关键词
Bayesian; MR-Only planning; Synthetic CT; CONVOLUTIONAL NEURAL-NETWORK; THERAPY; IMAGE; SIMULATION;
D O I
10.1002/mp.16666
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundThe use of synthetic computed tomography (CT) for radiotherapy treatment planning has received considerable attention because of the absence of ionizing radiation and close spatial correspondence to source magnetic resonance (MR) images, which have excellent tissue contrast. However, in an MR-only environment, little effort has been made to examine the quality of synthetic CT images without using the original CT images.PurposeTo estimate synthetic CT quality without referring to original CT images, this study established the relationship between synthetic CT uncertainty and Bayesian uncertainty, and proposed a new Bayesian deep network for generating synthetic CT images and estimating synthetic CT uncertainty for MR-only radiotherapy treatment planning.Methods and MaterialsA novel deep Bayesian network was formulated using probabilistic network weights. Two mathematical expressions were proposed to quantify the Bayesian uncertainty of the network and synthetic CT uncertainty, which was closely related to the mean absolute error (MAE) in Hounsfield Unit (HU) of synthetic CT. These uncertainties were examined to demonstrate the accuracy of representing the synthetic CT uncertainty using a Bayesian counterpart. We developed a hybrid Bayesian architecture and a new data normalization scheme, enabling the Bayesian network to generate both accurate synthetic CT and reliable uncertainty information when probabilistic weights were applied. The proposed method was evaluated in 59 patients (13/12/32/2 for training/validation/testing/uncertainty visualization) diagnosed with prostate cancer, who underwent same-day pelvic CT- and MR-acquisitions. To assess the relationship between Bayesian and synthetic CT uncertainties, linear and non-linear correlation coefficients were calculated on per-voxel, per-tissue, and per-patient bases. For accessing the accuracy of the CT number and dosimetric accuracy, the proposed method was compared with a commercially available atlas-based method (MRCAT) and a U-Net conditional-generative adversarial network (UcGAN).ResultsThe proposed model exhibited 44.33 MAE, outperforming UcGAN 52.51 and MRCAT 54.87. The gamma rate (2%/2 mm dose difference/distance to agreement) of the proposed model was 98.68%, comparable to that of UcGAN (98.60%) and MRCAT (98.56%). The per-patient and per-tissue linear correlation coefficients between the Bayesian and synthetic CT uncertainties ranged from 0.53 to 0.83, implying a moderate to strong linear correlation. Per-voxel correlation coefficients varied from -0.13 to 0.67 depending on the regions-of-interest evaluated, indicating tissue-dependent correlation. The R2 value for estimating MAE solely using Bayesian uncertainty was 0.98, suggesting that the uncertainty of the proposed model was an ideal candidate for predicting synthetic CT error, without referring to the original CT.ConclusionThis study established a relationship between the Bayesian model uncertainty and synthetic CT uncertainty. A novel Bayesian deep network was proposed to generate a synthetic CT and estimate its uncertainty. Various metrics were used to thoroughly examine the relationship between the uncertainties of the proposed Bayesian model and the generated synthetic CT. Compared with existing approaches, the proposed model showed comparable CT number and dosimetric accuracies. The experiments showed that the proposed Bayesian model was capable of producing accurate synthetic CT, and was an effective indicator of the uncertainty and error associated with synthetic CT in MR-only workflows.
引用
收藏
页码:1244 / 1262
页数:19
相关论文
共 50 条
  • [11] Deep learning-based synthetic CT generation for paediatric brain MR-only photon and proton radiotherapy
    Maspero, Matteo
    Bentvelzen, Laura G.
    Savenije, Mark H. F.
    Guerreiro, Filipa
    Seravalli, Enrica
    Janssens, Geert O.
    van den Berg, Cornelis A. T.
    Philippens, Marielle E. P.
    RADIOTHERAPY AND ONCOLOGY, 2020, 153 : 197 - 204
  • [12] Generation of synthetic CT with 3D deep convolutional neural networks for brain MR-only radiotherapy
    Aouadi, S.
    Hammoud, R.
    Torfeh, T.
    Paloor, S.
    Al-hammadi, N.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1377 - S1378
  • [13] Evaluation of Synthetic CT Image Generated Using a Neural Network for MR-Only Radiotherapy
    Tang, B.
    Fan, W.
    Wang, X.
    Li, J.
    Wang, P.
    Kang, S.
    Xiao, M.
    Orlandini, L. C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E296 - E297
  • [14] MR-Based Synthetic-CT Generation Using Generative Adversarial Network for Head and Neck MR-Only Radiotherapy
    Qi, M.
    Li, Y.
    Wu, A.
    Guo, F.
    Jia, Q.
    Zhou, L.
    Song, T.
    MEDICAL PHYSICS, 2019, 46 (06) : E112 - E112
  • [15] The benefit of MR-only radiotherapy treatment planning for anal and rectal cancers: A planning study
    Bird, David
    Nix, Michael G.
    McCallum, Hazel
    Teo, Mark
    Gilbert, Alexandra
    Casanova, Nathalie
    Cooper, Rachel
    Buckley, David L.
    Sebag-Montefiore, David
    Speight, Richard
    Al-Qaisieh, Bashar
    Henry, Ann M.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (11): : 41 - 53
  • [16] Toward MR-only radiotherapy treatment planning for moving targets
    Chugh, Brige
    Al-Ward, Shahad
    Soliman, Abraam
    Sarfehnia, Arman
    Kim, Anthony
    Lau, Angus
    Sahgal, Arjun
    Stanisz, Greg
    Keller, Brian
    MEDICAL PHYSICS, 2017, 44 (08) : 4395 - 4396
  • [17] Uncertainty in Multitask Learning: Joint Representations for Probabilistic MR-only Radiotherapy Planning
    Bragman, Felix J. S.
    Tanno, Ryutaro
    Eaton-Rosen, Zach
    Li, Wenqi
    Hawkes, David J.
    Ourselin, Sebastien
    Alexander, Daniel C.
    McClelland, Jamie R.
    Cardoso, M. Jorge
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2018, PT IV, 2018, 11073 : 3 - 11
  • [18] A Dixon Based Pseudo-CT Generation Method for MR-Only Radiotherapy Treatment Planning of the Pelvis and Head and Neck
    Maspero, M.
    Seevinck, P. R.
    Meijer, G. J.
    Lagendijk, J. J. W.
    Viergever, M. A.
    van den Berg, C. A. T.
    MEDICAL PHYSICS, 2015, 42 (06) : 3316 - 3316
  • [19] Joint MR to CT Synthesis and Organs-at-Risk Segmentation with Uncertainty Estimation for MR-Only Brain Radiotherapy Planning
    Mekki, L.
    Acharya, S.
    Ladra, M.
    Lee, J.
    MEDICAL PHYSICS, 2024, 51 (09) : 6618 - 6618
  • [20] Unsupervised AutoConfidence estimation for deep-learning synthetic-CT in MR-only liver radiotherapy
    Nix, M.
    Bird, D.
    Tyyger, M.
    Al-Qaisieh, B.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S584 - S585