A study of Bayesian deep network uncertainty and its application to synthetic CT generation for MR-only radiotherapy treatment planning

被引:3
|
作者
Law, Max Wai-Kong [1 ,3 ]
Tse, Mei-Yan [1 ]
Ho, Leon Chin-Chak [1 ]
Lau, Ka-Ki [1 ]
Wong, Oi Lei [2 ]
Yuan, Jing [2 ]
Cheung, Kin Yin [1 ]
Yu, Siu Ki [1 ]
机构
[1] Hong Kong Sanat & Hosp, Med Phys Dept, Hong Kong, Peoples R China
[2] Hong Kong Sanat & Hosp, Res Dept, Hong Kong, Peoples R China
[3] Hong Kong Sanat & Hosp, Eastern Med Ctr, Med Phys Dept, Hong Kong, Peoples R China
关键词
Bayesian; MR-Only planning; Synthetic CT; CONVOLUTIONAL NEURAL-NETWORK; THERAPY; IMAGE; SIMULATION;
D O I
10.1002/mp.16666
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundThe use of synthetic computed tomography (CT) for radiotherapy treatment planning has received considerable attention because of the absence of ionizing radiation and close spatial correspondence to source magnetic resonance (MR) images, which have excellent tissue contrast. However, in an MR-only environment, little effort has been made to examine the quality of synthetic CT images without using the original CT images.PurposeTo estimate synthetic CT quality without referring to original CT images, this study established the relationship between synthetic CT uncertainty and Bayesian uncertainty, and proposed a new Bayesian deep network for generating synthetic CT images and estimating synthetic CT uncertainty for MR-only radiotherapy treatment planning.Methods and MaterialsA novel deep Bayesian network was formulated using probabilistic network weights. Two mathematical expressions were proposed to quantify the Bayesian uncertainty of the network and synthetic CT uncertainty, which was closely related to the mean absolute error (MAE) in Hounsfield Unit (HU) of synthetic CT. These uncertainties were examined to demonstrate the accuracy of representing the synthetic CT uncertainty using a Bayesian counterpart. We developed a hybrid Bayesian architecture and a new data normalization scheme, enabling the Bayesian network to generate both accurate synthetic CT and reliable uncertainty information when probabilistic weights were applied. The proposed method was evaluated in 59 patients (13/12/32/2 for training/validation/testing/uncertainty visualization) diagnosed with prostate cancer, who underwent same-day pelvic CT- and MR-acquisitions. To assess the relationship between Bayesian and synthetic CT uncertainties, linear and non-linear correlation coefficients were calculated on per-voxel, per-tissue, and per-patient bases. For accessing the accuracy of the CT number and dosimetric accuracy, the proposed method was compared with a commercially available atlas-based method (MRCAT) and a U-Net conditional-generative adversarial network (UcGAN).ResultsThe proposed model exhibited 44.33 MAE, outperforming UcGAN 52.51 and MRCAT 54.87. The gamma rate (2%/2 mm dose difference/distance to agreement) of the proposed model was 98.68%, comparable to that of UcGAN (98.60%) and MRCAT (98.56%). The per-patient and per-tissue linear correlation coefficients between the Bayesian and synthetic CT uncertainties ranged from 0.53 to 0.83, implying a moderate to strong linear correlation. Per-voxel correlation coefficients varied from -0.13 to 0.67 depending on the regions-of-interest evaluated, indicating tissue-dependent correlation. The R2 value for estimating MAE solely using Bayesian uncertainty was 0.98, suggesting that the uncertainty of the proposed model was an ideal candidate for predicting synthetic CT error, without referring to the original CT.ConclusionThis study established a relationship between the Bayesian model uncertainty and synthetic CT uncertainty. A novel Bayesian deep network was proposed to generate a synthetic CT and estimate its uncertainty. Various metrics were used to thoroughly examine the relationship between the uncertainties of the proposed Bayesian model and the generated synthetic CT. Compared with existing approaches, the proposed model showed comparable CT number and dosimetric accuracies. The experiments showed that the proposed Bayesian model was capable of producing accurate synthetic CT, and was an effective indicator of the uncertainty and error associated with synthetic CT in MR-only workflows.
引用
收藏
页码:1244 / 1262
页数:19
相关论文
共 50 条
  • [21] Dose comparison study for CT and MR-only prostate IMRT treatment planning
    Maspero, M.
    Schubert, G.
    Lindstrom, M.
    Hoesl, M.
    Seevinck, P. R.
    Meijer, G. J.
    Viergever, M. A.
    Lagendijk, J. J. W.
    Van den Berg, C. A. T.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S864 - S865
  • [22] Dose evaluation of fast synthetic-CT generation using a generative adversarial network for general pelvis MR-only radiotherapy
    Maspero, Matteo
    Savenije, Mark H. F.
    Dinkla, Anna M.
    Seevinck, Peter R.
    Intven, Martijn P. W.
    Jurgenliemk-Schulz, Ina M.
    Kerkmeijer, Linda G. W.
    van den Berg, Cornelis A. T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (18):
  • [23] CT synthesis with deep learning for MR-only radiotherap planning: a review
    Roh, Junghyun
    Ryu, Dongmin
    Lee, Jimin
    BIOMEDICAL ENGINEERING LETTERS, 2024, 14 (06) : 1259 - 1278
  • [24] Bony structure enhanced synthetic CT generation using Dixon sequences for pelvis MR-only radiotherapy
    Liang, Xiao
    Yen, Allen
    Bai, Ti
    Godley, Andrew
    Shen, Chenyang
    Wu, Junjie
    Meng, Boyu
    Lin, Mu-Han
    Medin, Paul
    Yan, Yulong
    Owrangi, Amir
    Desai, Neil
    Hannan, Raquibul
    Garant, Aurelie
    Jiang, Steve
    Deng, Jie
    MEDICAL PHYSICS, 2023, 50 (12) : 7368 - 7382
  • [25] Synthetic CT reconstruction using a deep spatial pyramid convolutional framework for MR-only breast radiotherapy
    Olberg, Sven
    Zhang, Hao
    Kennedy, William R.
    Chun, Jaehee
    Rodriguez, Vivian
    Zoberi, Imran
    Thomas, Maria A.
    Kim, Jin Sung
    Mutic, Sasa
    Green, Olga L.
    Park, Justin C.
    MEDICAL PHYSICS, 2019, 46 (09) : 4135 - 4147
  • [26] Patient specific quality assurance for synthetic CT in MR-only radiotherapy of the abdomen
    Dal Bello, R.
    Lapaeva, M.
    Agustina, A.
    Wallimann, P.
    Gunther, M.
    Konukoglu, E.
    Andratschke, N.
    Guckenberger, M.
    Tanadini-Lang, S.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S74 - S75
  • [27] Results of the ESTRO 2023 survey on the use of synthetic CT in MR-only radiotherapy
    Fusella, Marco
    Cusumano, Davide
    Alvarez-Andres, Emilie
    Dal Bello, Riccardo
    Dhont, Jennifer
    Garibaldi, Cristina
    Villegas, Fernanda
    Placidi, Lorenzo
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3801 - S3803
  • [28] Validation of a Commercial Continuous Hounsfield Unit (HU) Pelvis Synthetic CT Platform for MR-Only Prostate Radiotherapy Treatment Planning
    Yu, V.
    Hunt, M.
    Cervino, L.
    Damato, A.
    Tyagi, N.
    MEDICAL PHYSICS, 2020, 47 (06) : E669 - E669
  • [29] Dosimetric evaluation of synthetic CT image generated using a neural network for MR-only brain radiotherapy
    Tang, Bin
    Wu, Fan
    Fu, Yuchuan
    Wang, Xianliang
    Wang, Pei
    Orlandini, Lucia Clara
    Li, Jie
    Hou, Qing
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (03): : 55 - 62
  • [30] Robustness of Conditional Generative Adversarial Networks in Generating Head and Neck Synthetic CT Images for MR-Only Radiotherapy Treatment Planning
    Klages, P.
    Benslimane, I.
    Riyahi, S.
    Jiang, J.
    Hunt, M.
    Deasy, J.
    Veeraraghavan, H.
    Tyagi, N.
    MEDICAL PHYSICS, 2019, 46 (06) : E295 - E296