A study of Bayesian deep network uncertainty and its application to synthetic CT generation for MR-only radiotherapy treatment planning

被引:3
|
作者
Law, Max Wai-Kong [1 ,3 ]
Tse, Mei-Yan [1 ]
Ho, Leon Chin-Chak [1 ]
Lau, Ka-Ki [1 ]
Wong, Oi Lei [2 ]
Yuan, Jing [2 ]
Cheung, Kin Yin [1 ]
Yu, Siu Ki [1 ]
机构
[1] Hong Kong Sanat & Hosp, Med Phys Dept, Hong Kong, Peoples R China
[2] Hong Kong Sanat & Hosp, Res Dept, Hong Kong, Peoples R China
[3] Hong Kong Sanat & Hosp, Eastern Med Ctr, Med Phys Dept, Hong Kong, Peoples R China
关键词
Bayesian; MR-Only planning; Synthetic CT; CONVOLUTIONAL NEURAL-NETWORK; THERAPY; IMAGE; SIMULATION;
D O I
10.1002/mp.16666
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundThe use of synthetic computed tomography (CT) for radiotherapy treatment planning has received considerable attention because of the absence of ionizing radiation and close spatial correspondence to source magnetic resonance (MR) images, which have excellent tissue contrast. However, in an MR-only environment, little effort has been made to examine the quality of synthetic CT images without using the original CT images.PurposeTo estimate synthetic CT quality without referring to original CT images, this study established the relationship between synthetic CT uncertainty and Bayesian uncertainty, and proposed a new Bayesian deep network for generating synthetic CT images and estimating synthetic CT uncertainty for MR-only radiotherapy treatment planning.Methods and MaterialsA novel deep Bayesian network was formulated using probabilistic network weights. Two mathematical expressions were proposed to quantify the Bayesian uncertainty of the network and synthetic CT uncertainty, which was closely related to the mean absolute error (MAE) in Hounsfield Unit (HU) of synthetic CT. These uncertainties were examined to demonstrate the accuracy of representing the synthetic CT uncertainty using a Bayesian counterpart. We developed a hybrid Bayesian architecture and a new data normalization scheme, enabling the Bayesian network to generate both accurate synthetic CT and reliable uncertainty information when probabilistic weights were applied. The proposed method was evaluated in 59 patients (13/12/32/2 for training/validation/testing/uncertainty visualization) diagnosed with prostate cancer, who underwent same-day pelvic CT- and MR-acquisitions. To assess the relationship between Bayesian and synthetic CT uncertainties, linear and non-linear correlation coefficients were calculated on per-voxel, per-tissue, and per-patient bases. For accessing the accuracy of the CT number and dosimetric accuracy, the proposed method was compared with a commercially available atlas-based method (MRCAT) and a U-Net conditional-generative adversarial network (UcGAN).ResultsThe proposed model exhibited 44.33 MAE, outperforming UcGAN 52.51 and MRCAT 54.87. The gamma rate (2%/2 mm dose difference/distance to agreement) of the proposed model was 98.68%, comparable to that of UcGAN (98.60%) and MRCAT (98.56%). The per-patient and per-tissue linear correlation coefficients between the Bayesian and synthetic CT uncertainties ranged from 0.53 to 0.83, implying a moderate to strong linear correlation. Per-voxel correlation coefficients varied from -0.13 to 0.67 depending on the regions-of-interest evaluated, indicating tissue-dependent correlation. The R2 value for estimating MAE solely using Bayesian uncertainty was 0.98, suggesting that the uncertainty of the proposed model was an ideal candidate for predicting synthetic CT error, without referring to the original CT.ConclusionThis study established a relationship between the Bayesian model uncertainty and synthetic CT uncertainty. A novel Bayesian deep network was proposed to generate a synthetic CT and estimate its uncertainty. Various metrics were used to thoroughly examine the relationship between the uncertainties of the proposed Bayesian model and the generated synthetic CT. Compared with existing approaches, the proposed model showed comparable CT number and dosimetric accuracies. The experiments showed that the proposed Bayesian model was capable of producing accurate synthetic CT, and was an effective indicator of the uncertainty and error associated with synthetic CT in MR-only workflows.
引用
收藏
页码:1244 / 1262
页数:19
相关论文
共 50 条
  • [1] Multicentre, deep learning, synthetic-CT generation for ano-rectal MR-only radiotherapy treatment planning
    Bird, David
    Nix, Michael G.
    McCallum, Hazel
    Teo, Mark
    Gilbert, Alexandra
    Casanova, Nathalie
    Cooper, Rachel
    Buckley, David L.
    Sebag-Montefiore, David
    Speight, Richard
    Al-Qaisieh, Bashar
    Henry, Ann M.
    RADIOTHERAPY AND ONCOLOGY, 2021, 156 : 23 - 28
  • [2] CycleSeg: Simultaneous synthetic CT generation and unsupervised segmentation for MR-only radiotherapy treatment planning of prostate cancer
    Luu, Huan Minh
    Yoo, Gyu Sang
    Park, Won
    Park, Sung-Hong
    MEDICAL PHYSICS, 2024, 51 (06) : 4365 - 4379
  • [3] Towards MR-Only Radiotherapy Treatment Planning: Synthetic CT Generation Using Multi-view Deep Convolutional Neural Networks
    Zhao, Yu
    Liao, Shu
    Guo, Yimo
    Zhao, Liang
    Yan, Zhennan
    Hong, Sungmin
    Hermosillo, Gerardo
    Liu, Tianming
    Zhou, Xiang Sean
    Zhan, Yiqiang
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2018, PT I, 2018, 11070 : 286 - 294
  • [4] A deep learning model to generate synthetic CT for prostate MR-only radiotherapy dose planning: a multicenter study
    Tahri, Safaa
    Texier, Blanche
    Nunes, Jean-Claude
    Hemon, Cedric
    Lekieffre, Pauline
    Collot, Emma
    Chourak, Hilda
    Le Guevelou, Jennifer
    Greer, Peter
    Dowling, Jason
    Acosta, Oscar
    Bessieres, Igor
    Marage, Louis
    Boue-Rafle, Adrien
    De Crevoisier, Renaud
    Lafond, Caroline
    Barateau, Anais
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [5] Dosimetric evaluation of deep learning based synthetic-CT generation for MR-only brain radiotherapy
    Dinkla, A. M.
    Wolterink, J. M.
    Maspero, M.
    Savenije, M. H. F.
    Verhoeff, J. J. C.
    Isgum, I.
    Seevinck, P. R.
    Lagendijk, J. J. W.
    Van den Berg, C. A. T.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S151 - S151
  • [6] Preserving Structural Consistency in the Generation of Synthetic CT in Pelvic MR-Only Radiation Treatment Planning
    Li, X.
    Lin, F. Y.
    Jia, L. C.
    Liu, T.
    He, S. M.
    Zhang, W.
    Zhang, M.
    Wang, Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E686 - E686
  • [7] Abdominal Synthetic CT Generation for MR-Only Liver Radiotherapy Using Conditional Generative Adversarial Network
    Fu, J.
    Santhanam, A.
    Cao, M.
    Guo, M.
    Singhrao, K.
    Yu, V.
    Ruan, D.
    Low, D.
    Lewis, J.
    MEDICAL PHYSICS, 2018, 45 (06) : E701 - E701
  • [8] Structurally-constrained optical-flow-guided adversarial generation of synthetic CT for MR-only radiotherapy treatment planning
    Vajpayee, Rajat
    Agrawal, Vismay
    Krishnamurthi, Ganapathy
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [9] Structurally-constrained optical-flow-guided adversarial generation of synthetic CT for MR-only radiotherapy treatment planning
    Rajat Vajpayee
    Vismay Agrawal
    Ganapathy Krishnamurthi
    Scientific Reports, 12
  • [10] The rationale for MR-only treatment planning for external radiotherapy
    Jonsson, Joakim
    Nyholm, Tufve
    Soderkvist, Karin
    CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2019, 18 : 60 - 65