SEM Analysis and Micro-CT Evaluation of Four Dental Implants after Three Different Mechanical Requests-In Vitro Study

被引:2
|
作者
Vinhas, Ana Sofia [1 ]
Salazar, Filomena [1 ]
Mendes, Jose Manuel [1 ]
Silva, Antonio Sergio [1 ]
Rios-Carrasco, Blanca [2 ]
Rios-Santos, Jose Vicente [2 ]
Gil, Javier [3 ]
Herrero-Climent, Mariano [4 ]
Aroso, Carlos [1 ]
机构
[1] Univ Inst Hlth Sci IUCS, Oral Pathol & Rehabil Res Unit UNIPRO, CESPU, Rua Cent Gandra, P-4585116 Gandra, Portugal
[2] Univ Seville, Sch Dent, Dept Periodontol, C Avicena S-N, Seville 41009, Spain
[3] Univ Int Catalunya, Bioengn Inst Technol, Fac Med & Hlth Sci, St Cugat Barcelona 08195, Spain
[4] Porto Dent Inst, P-4150518 Porto, Portugal
关键词
implant-abutment connection; implant-abutment axial displacement; implant-abutment wear; fatigue-test; mechanical stresses; SEM analysis; Micro-CT evaluation; EXTERNAL HEXAGON; ABUTMENT CONNECTION; INTERNAL CONNECTION; AXIAL DISPLACEMENT; FRACTURE-BEHAVIOR; REVERSE TORQUE; FATIGUE; TITANIUM; ROUGHNESS; PERFORMANCE;
D O I
10.3390/ma17020434
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Statement of problem: Implant-supported rehabilitations are an increasingly frequent practice to replace lost teeth. Before clinical application, all implant components should demonstrate suitable durability in laboratory studies, through fatigue tests. Objective: The purpose of this in vitro study was to evaluate the integrity and wear of implant components using SEM, and to assess the axial displacement of the implant-abutment assembly by Micro-CT, in different implant connections, after three distinct mechanical requests. Materials and methods: Four KLOCKNER implants (external connection SK2 and KL; and internal connection VEGA and ESSENTIAL) were submitted to three different mechanical requests: single tightening, multiple tightening, and multiple tightening and cyclic loading (500 N x 100 cycles). A total of 16 samples were evaluated by SEM, by the X-ray Bragg-Brentano method to obtain residual stresses, and scratch tests were realized for each surface and Micro-CT (4 control samples; 4 single tightening; 4 multiple tightening; 4 multiple tightening and cyclic loading). All dental implants were fabricated with commercially pure titanium (grade 3 titanium). Surface topography and axial displacement of abutment into the implant, from each group, were evaluated by SEM and Micro-CT. Results: In the manufacturing state, implants and abutments revealed minor structural changes and minimal damage from the machining process. The application of the tightening torque and loading was decisive in the appearance and increase in contact marks on the faces of the hexagon of the abutment and the implant. Vega has the maximum compressive residual stress and, as a consequence, higher scratch force. The abutment-implant distances in SK2 and KL samples did not show statistically significant differences, for any of the mechanical demands analyzed. In contrast, statistically significant differences were observed in abutment-implant distance in the internal connection implants Vega and Essential. Conclusions: The application of mechanical compression loads caused deformation and contact marks in all models tested. Only internal connection implants revealed an axial displacement of the abutment into the implant, but at a general level, a clear intrusion of the abutment into the implant could only be confirmed in the Essential model, which obtained its maximal axial displacement with cyclic loading.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Micro-CT Structure Analysis on Dental Implants: Preliminary In Vitro Trial
    Galletti, Fulvia
    D'Angelo, Tommaso
    Fiorillo, Luca
    Lo Giudice, Paola
    Irrera, Natasha
    Rizzo, Giuseppina
    Cervino, Gabriele
    PROSTHESIS, 2024, 6 (06): : 1437 - 1447
  • [2] Evaluation of the sealing ability of different root canal sealers: a combined SEM and micro-CT study
    Huang, Yan
    Orhan, Kaan
    Celikten, Berkan
    Orhan, Ayse Isil
    Tufenkci, Pelin
    Sevimay, Semra
    JOURNAL OF APPLIED ORAL SCIENCE, 2018, 26
  • [3] Primary Stability of Implants Inserted into Polyurethane Blocks: Micro-CT and Analysis In Vitro
    Haddad, Chadi Dura
    Andreatti, Ludovica
    Zelezetsky, Igor
    Porrelli, Davide
    Turco, Gianluca
    Bevilacqua, Lorenzo
    Maglione, Michele
    BIOENGINEERING-BASEL, 2024, 11 (04):
  • [4] Osseointegration of Tantalum Trabecular Metal in Titanium Dental Implants: Histological and Micro-CT Study
    Al Deeb, Modhi
    Aldosari, Abdullah AlFarraj
    Anil, Sukumaran
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2023, 14 (07)
  • [5] Effectiveness of Different Methods in Removing Dentin Caries of Primary Teeth: Micro-CT and SEM Evaluation
    Duruk, Gulsum
    Kizilci, Esra
    Malkoc, Meral Arslan
    JOURNAL OF CLINICAL PEDIATRIC DENTISTRY, 2022, 46 (03) : 211 - 218
  • [6] Evaluation of the Loss of Surface Roughness Following the Use of Four Different Instruments for Mechanical Debridement of Dental Implants: An In-vitro Pilot Study
    Kumar S.
    Yewale M.
    Parthasarathi N.L.
    Balasundaram R.
    Gopalkrishna P.
    Bhat S.G.
    Journal of Bio- and Tribo-Corrosion, 2024, 10 (4)
  • [7] Micro-CT and nano-CT analysis of filling quality of three different endodontic sealers
    Huang, Yan
    Celikten, Berkan
    Vasconcelos, Karla de Faria
    Pinheiro Nicolielo, Laura Ferreira
    Lippiatt, Nicholas
    Buyuksungur, Arda
    Jacobs, Reinhilde
    Orhan, Kaan
    DENTOMAXILLOFACIAL RADIOLOGY, 2017, 46 (08)
  • [8] Micro-CT observation of rat dental pulp healing after pulpotomy in in vivo study
    Osuga, Naoto
    Yang, Jing
    Yamakawa, Yoko
    Ninomiya, Tadashi
    Arai, Yoshinori
    Wang Raorao
    Iwasaki, Hiroshi
    Miyazawa, Hiroo
    PEDIATRIC DENTAL JOURNAL, 2006, 16 (02) : 132 - 137
  • [9] An evaluation of insertion sites for mini-implants A micro-CT study of human autopsy material
    Laursen, Morten G.
    Melsen, Birte
    Cattaneo, Paolo M.
    ANGLE ORTHODONTIST, 2013, 83 (02) : 222 - 229
  • [10] Bone regeneration using bilayer bone augmentation around dental implants: A preliminary study by micro-CT in dogs
    Woo-Sung Choi