SEM Analysis and Micro-CT Evaluation of Four Dental Implants after Three Different Mechanical Requests-In Vitro Study

被引:2
|
作者
Vinhas, Ana Sofia [1 ]
Salazar, Filomena [1 ]
Mendes, Jose Manuel [1 ]
Silva, Antonio Sergio [1 ]
Rios-Carrasco, Blanca [2 ]
Rios-Santos, Jose Vicente [2 ]
Gil, Javier [3 ]
Herrero-Climent, Mariano [4 ]
Aroso, Carlos [1 ]
机构
[1] Univ Inst Hlth Sci IUCS, Oral Pathol & Rehabil Res Unit UNIPRO, CESPU, Rua Cent Gandra, P-4585116 Gandra, Portugal
[2] Univ Seville, Sch Dent, Dept Periodontol, C Avicena S-N, Seville 41009, Spain
[3] Univ Int Catalunya, Bioengn Inst Technol, Fac Med & Hlth Sci, St Cugat Barcelona 08195, Spain
[4] Porto Dent Inst, P-4150518 Porto, Portugal
关键词
implant-abutment connection; implant-abutment axial displacement; implant-abutment wear; fatigue-test; mechanical stresses; SEM analysis; Micro-CT evaluation; EXTERNAL HEXAGON; ABUTMENT CONNECTION; INTERNAL CONNECTION; AXIAL DISPLACEMENT; FRACTURE-BEHAVIOR; REVERSE TORQUE; FATIGUE; TITANIUM; ROUGHNESS; PERFORMANCE;
D O I
10.3390/ma17020434
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Statement of problem: Implant-supported rehabilitations are an increasingly frequent practice to replace lost teeth. Before clinical application, all implant components should demonstrate suitable durability in laboratory studies, through fatigue tests. Objective: The purpose of this in vitro study was to evaluate the integrity and wear of implant components using SEM, and to assess the axial displacement of the implant-abutment assembly by Micro-CT, in different implant connections, after three distinct mechanical requests. Materials and methods: Four KLOCKNER implants (external connection SK2 and KL; and internal connection VEGA and ESSENTIAL) were submitted to three different mechanical requests: single tightening, multiple tightening, and multiple tightening and cyclic loading (500 N x 100 cycles). A total of 16 samples were evaluated by SEM, by the X-ray Bragg-Brentano method to obtain residual stresses, and scratch tests were realized for each surface and Micro-CT (4 control samples; 4 single tightening; 4 multiple tightening; 4 multiple tightening and cyclic loading). All dental implants were fabricated with commercially pure titanium (grade 3 titanium). Surface topography and axial displacement of abutment into the implant, from each group, were evaluated by SEM and Micro-CT. Results: In the manufacturing state, implants and abutments revealed minor structural changes and minimal damage from the machining process. The application of the tightening torque and loading was decisive in the appearance and increase in contact marks on the faces of the hexagon of the abutment and the implant. Vega has the maximum compressive residual stress and, as a consequence, higher scratch force. The abutment-implant distances in SK2 and KL samples did not show statistically significant differences, for any of the mechanical demands analyzed. In contrast, statistically significant differences were observed in abutment-implant distance in the internal connection implants Vega and Essential. Conclusions: The application of mechanical compression loads caused deformation and contact marks in all models tested. Only internal connection implants revealed an axial displacement of the abutment into the implant, but at a general level, a clear intrusion of the abutment into the implant could only be confirmed in the Essential model, which obtained its maximal axial displacement with cyclic loading.
引用
收藏
页数:21
相关论文
共 50 条
  • [41] Evaluation of interfacial adaptation of different resin filling techniques for class I and II restorations by micro-CT and OCT analysis: A systematic review of in vitro studies
    Silva, Claudia
    Novaes, Raquel
    Santos, Ana
    Edvaldo Filho
    Nascimento, Angela
    Assis, Paulo
    Braz, Rodivan
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2023, 147
  • [42] Evaluation of interfacial adaptation of different resin filling techniques for class I and II restorations by micro-CT and OCT analysis: A systematic review of in vitro studies
    Silva C.
    Novaes R.
    Santos A.
    Filho E.
    Nascimento A.
    Assis P.
    Braz R.
    Journal of the Mechanical Behavior of Biomedical Materials, 2023, 147
  • [43] Comparison of Three Different Orthodontic Adhesives Bonded to Metallic and Ceramic Brackets: SEM and SEM/EDX Analysis (In Vitro Study)
    Arifi, Arif
    Gjorgievska, Elizabeta S.
    Gavrilovic, Irena
    Coleman, Nichola J.
    Vuletic, Marko
    Gabric, Dragana
    ACTA STOMATOLOGICA CROATICA, 2024, 58 (01) : 18 - 29
  • [44] Evaluation of interfacial adaptation of different resin filling techniques for class I and II restorations by micro-CT and OCT analysis: A systematic review of in vitro studies
    Silva, Claudia
    Novaes, Raquel
    Santos, Ana
    Edvaldo Filho
    Nascimento, Angela
    Assis, Paulo
    Braz, Rodivan
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2023, 147
  • [45] Microcomputed tomography (micro-CT) analysis of apical mandibular premolar in relation to clinical sign presentation: An in vitro study
    Iwani, Samsudin Nurulaqmar
    Kamaruzaman, Marlena
    Jawami, Afiq Azizi
    SAUDI DENTAL JOURNAL, 2024, 36 (01) : 129 - 133
  • [46] Present and future in the use of micro-CT scanner 3D analysis for the study of dental and root canal morphology
    Grande, Nicola M.
    Plotino, Gianluca
    Gambarini, Gianluca
    Testarelli, Luca
    D'Ambrosio, Ferdinando
    Pecci, Raffaella
    Bedini, Rossella
    ANNALI DELL ISTITUTO SUPERIORE DI SANITA, 2012, 48 (01): : 26 - 34
  • [47] Micro-CT Analysis of Apical Plug Using Various Premixed Bio-ceramic Putties: An In Vitro Study
    Eldehna, Alaa M.
    Abdelkafy, Heba
    Salem, Nada A.
    Elzahar, Sherief
    Abdel-ghany, Dina M.
    Abd-allah, Nouralhouda F.
    Kharadly, Dina Yousry E. L.
    Elashiry, Mohamed Mohamed
    EUROPEAN ENDODONTIC JOURNAL, 2025, 10 (01): : 18 - 26
  • [48] Incidence of microcracks after preparation of straight and curved root canals with three different NiTi instrumentation techniques assessed by micro-CT
    Roedig, Tina
    Kraemer, Juliane
    Mueller, Christine
    Wiegand, Annette
    Haupt, Franziska
    Rizk, Marta
    AUSTRALIAN ENDODONTIC JOURNAL, 2019, 45 (03) : 394 - 399
  • [49] Micro-CT evaluation of ProTaper Next and WaveOne Gold shaping in maxillary first molars curved canals: an in vitro study
    Tutino, Fabio
    Alovisi, Mario
    Bernardi, Mattia
    Carpegna, Giorgia
    Comba, Allegra
    Pasqualini, Damiano
    Scotti, Nicola
    Berutti, Elio
    GIORNALE ITALIANO DI ENDODONZIA, 2019, 33 (01): : 65 - 69
  • [50] In-vitro analysis of maxillary first molars morphology using three dimensional Micro-CT imaging: considerations for restorative dentistry
    Baltacioglu, Ismail Hakki
    Demirel, Gulbike
    Kolsuz, Mehmet Eray
    Orhan, Kaan
    EUROPEAN ORAL RESEARCH, 2018, 52 (02) : 75 - 81