Micro-CT Structure Analysis on Dental Implants: Preliminary In Vitro Trial

被引:0
|
作者
Galletti, Fulvia [1 ]
D'Angelo, Tommaso [1 ]
Fiorillo, Luca [1 ,2 ,3 ,4 ]
Lo Giudice, Paola [5 ]
Irrera, Natasha [4 ]
Rizzo, Giuseppina [4 ]
Cervino, Gabriele [1 ]
机构
[1] Univ Messina, Dept Biomed & Dent Sci & Morphofunct Imaging, Via Consolare Valeria 1, I-98125 Messina, Italy
[2] Univ Campania Luigi Vanvitelli, Multidisciplinary Dept Med Surg & Odontostomatol S, I-80121 Naples, Italy
[3] Dr DY Patil Vidyapeeth, Dr DY Patil Dent Coll & Hosp, Dept Dent Cell Res, Pune 411018, India
[4] Univ Messina, Dept Clin & Expt Med, Via Consolare Valeria 1, I-98125 Messina, Italy
[5] Univ Catania, Dept Med & Surg Sci, Sect Dent, I-95123 Catania, Italy
来源
PROSTHESIS | 2024年 / 6卷 / 06期
关键词
dental implants; microcomputed tomography (micro-CT); osseointegration; implant stability; OSSEOINTEGRATION;
D O I
10.3390/prosthesis6060104
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Introduction: This preliminary in vitro study aims to evaluate the application of micro-CT in analyzing the microstructural coupling between dental implant fixtures and prosthetic abutments, with an emphasis on understanding the effectiveness and limitations of this technique in dental implantology. Materials and Methods: A search of PubMed, MEDLINE, and the Cochrane Library up to May 2024 identified eight relevant studies that examined different facets of dental implantology, such as osseointegration, implant stability, and the comparative accuracy of micro-CT versus other imaging techniques. A comparative micro-CT radiographic analysis was performed on five different implant fixtures with respective prosthetic and healing abutments, by using SkyScan1174 micro-CT. Results: The reviewed studies demonstrated that micro-CT is reliable for assessing bone quality, implant stability, and the microstructural integrity of dental implants. Micro-computed tomography (micro-CT) studies reveal bone-implant contact (BIC) ratios of 40-80%, bone volume per total volume (BV/TV) values of 20-60%, and detect microgaps as small as 0.3 mu m, highlighting its high-resolution capability (5-10 mu m) for detailed implant analysis. The comparative analysis of the implant fixtures analyzed the implant-abutment connection, highlighting the relevance of implant design for ensuring stability. Conclusions: Micro-CT analysis has proven to be a valuable tool for evaluating the intricate microstructural properties of dental implants, offering insights into implant stability, bone quality, and osseointegration. The literature reviewed highlights consistent findings that underscore micro-CT's accuracy and reliability in capturing high-resolution data, suggesting its potential as a standard imaging modality in implant research and clinical assessment.
引用
收藏
页码:1437 / 1447
页数:11
相关论文
共 50 条
  • [1] Primary Stability of Implants Inserted into Polyurethane Blocks: Micro-CT and Analysis In Vitro
    Haddad, Chadi Dura
    Andreatti, Ludovica
    Zelezetsky, Igor
    Porrelli, Davide
    Turco, Gianluca
    Bevilacqua, Lorenzo
    Maglione, Michele
    BIOENGINEERING-BASEL, 2024, 11 (04):
  • [2] SEM Analysis and Micro-CT Evaluation of Four Dental Implants after Three Different Mechanical Requests-In Vitro Study
    Vinhas, Ana Sofia
    Salazar, Filomena
    Mendes, Jose Manuel
    Silva, Antonio Sergio
    Rios-Carrasco, Blanca
    Rios-Santos, Jose Vicente
    Gil, Javier
    Herrero-Climent, Mariano
    Aroso, Carlos
    MATERIALS, 2024, 17 (02)
  • [3] Bone Regeneration Using Bilayer Bone Augmentation around Dental Implants: A Preliminary Study by Micro-CT in Dogs
    Choi, Woo-Sung
    Yoon, Hyun-Joong
    TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2016, 13 (03) : 304 - 310
  • [4] Bone regeneration using bilayer bone augmentation around dental implants: A preliminary study by micro-CT in dogs
    Woo-Sung Choi
    Hyun-Joong Yoon
    Tissue Engineering and Regenerative Medicine, 2016, 13 : 304 - 310
  • [5] Bone Quantification Around Chitosan-Coated Titanium Dental Implants: A Preliminary Study by Micro-CT Analysis in Jaw of a Canine Model
    Lopez-Valverde, Nansi
    Lopez-Valverde, Antonio
    Paz Cortes, Marta
    Rodriguez, Cinthia
    De Sousa, Bruno Macedo
    Manuel Aragoneses, Juan
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [6] Osseointegration of Tantalum Trabecular Metal in Titanium Dental Implants: Histological and Micro-CT Study
    Al Deeb, Modhi
    Aldosari, Abdullah AlFarraj
    Anil, Sukumaran
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2023, 14 (07)
  • [7] MICRO-CT ANALYSIS OF GLASS KNITTED FABRIC STRUCTURE
    Harjkova, Galina
    Barburski, Marcin
    Lomov, Stepan V.
    Kononova, Olga
    12TH INTERNATIONAL SCIENTIFIC CONFERENCE ENGINEERING FOR RURAL DEVELOPMENT, 2013, : 223 - 227
  • [8] Analysis of atherosclerosis with micro-CT
    Mohr, A
    Roemer, F
    Genant, H
    RADIOLOGY, 2005, 235 (01) : 338 - 339
  • [9] Micro-CT Analysis of Microgap at a Novel Two-Piece Dental Implant Comprising a Replaceable Sleeve In Vitro
    Kapishnikov, Sergey
    Gadyukov, Adir
    Chaushu, Gavriel
    Chaushu, Liat
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (03) : 451 - 459
  • [10] Effect of low-level laser therapy on osseointegration of titanium dental implants in ovariectomized rabbits: biomechanics and micro-CT analysis
    Karakaya, Mustafa
    Demirbas, Ahmet Emin
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)