Micro-CT and nano-CT analysis of filling quality of three different endodontic sealers

被引:44
|
作者
Huang, Yan [1 ,2 ]
Celikten, Berkan [1 ]
Vasconcelos, Karla de Faria [1 ,3 ]
Pinheiro Nicolielo, Laura Ferreira [1 ]
Lippiatt, Nicholas [4 ]
Buyuksungur, Arda [5 ,6 ]
Jacobs, Reinhilde [1 ,7 ]
Orhan, Kaan [8 ]
机构
[1] Katholieke Univ Leuven, OMFS IMPATH, Oral & Maxillofacial Surg Imaging & Pathol, Leuven, Belgium
[2] Sichuan Univ, State Key Lab Oral Dis, West China Coll Stomatol, Chengdu, Sichuan, Peoples R China
[3] Univ Estadual Campinas, Piracicaba Dent Sch, Div Oral Radiol, Dept Oral Diag, Piracicaba, Brazil
[4] Katholieke Univ Leuven, Dept Mat Engn Mat Performance & Nondestruct Testi, Leuven, Belgium
[5] Middle East Tech Univ, BIOMATEN, Ankara, Turkey
[6] Middle East Tech Univ, Dept Biotechnol, Ankara, Turkey
[7] Karolinska Inst, Dept Dent Med, Stockholm, Sweden
[8] Ankara Univ, Dept Dento Maxillofacial Radiol, Ankara, Turkey
基金
比利时弗兰德研究基金会; 巴西圣保罗研究基金会;
关键词
MicroCT; nanostructures; root canal filling materials; dental seal; endotonic obturation; ROOT FILLINGS; SINGLE-POINT; ABILITY; LEAKAGE;
D O I
10.1259/dmfr.20170223
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To investigate voids in different root canal sealers using micro-CT and nano-CT, and to explore the feasibility of using nano-CT for quantitative analysis of sealer filling quality. Methods: 30 extracted mandibular central incisors were randomly assigned into three groups according to the applied root canal sealers (Total BC Sealer, Sure Seal Root, AH Plus) by the single cone technique. Subsequently, micro-CT and nano-CT were performed to analyse the incidence rate of voids, void fraction, void volume and their distribution in each sample. Results: Micro-CT evaluation showed no significant difference among sealers for the incidence rate of voids or void fraction in the whole filling materials (p > 0.05), whereas a significant difference was found between AH Plus and the other two sealers using nano-CT (p < 0.05). All three sealers presented less void volume in the apical third; however, higher void volumes were observed in the apical and coronal thirds in AH Plus using micro-CT (p < 0.05), while nano-CT results displayed higher void volume in AH Plus among all the sealers and regions (p < 0.05). Conclusions: Bioactive sealers showed higher root filling rate, lower incidence rate of voids, void fraction and void volume than AH Plus under nano-CT analysis, when round root canals were treated by the single cone technique. The disparate results suggest that the higher resolution of nano-CT have a greater ability of distinguishing internal porosity, and therefore suggesting the potential use of nano-CT in quantitative analysis of filling quality of sealers.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Compensation of mechanical inaccuracies in micro-CT and nano-CT
    Sasov, Alexander
    Liu, Xuan
    Salmon, Phil L.
    [J]. DEVELOPMENTS IN X-RAY TOMOGRAPHY VI, 2008, 7078
  • [2] Evaluation of Threshold Values for Root Canal Filling Voids in Micro-CT and Nano-CT Images
    Orhan, Kaan
    Jacobs, Reinhilde
    Celikten, Berkan
    Huang, Yan
    Vasconcelos, Karla de Faria
    Nicolielo, Laura Ferreira Pinheiro
    Buyuksungur, Arda
    Van Dessel, Jeroen
    [J]. SCANNING, 2018,
  • [3] Key components for artifact-free micro-CT and nano-CT instruments
    Sasov, Alexander
    Pauwels, Bart
    Liu, Xuan
    Bruyndonckx, Peter
    [J]. DEVELOPMENTS IN X-RAY TOMOGRAPHY VII, 2010, 7804
  • [4] Assessment of the root filling volume in C-shaped root canal on cone-beam CT and micro-CT in relation to nano-CT
    Candemil, Amanda Pelegrin
    Mazzi-Chaves, Jardel Francisco
    Oliveira, Matheus Lima
    Ambrosano, Guilherme Bovi
    Vasconcelos, Karla Farias
    Pauwels, Ruben
    Jacobs, Reinhilde
    Sousa-Neto, Manoel Damiao
    [J]. CLINICAL ORAL INVESTIGATIONS, 2023, 27 (11) : 6413 - 6420
  • [5] Assessment of the root filling volume in C-shaped root canal on cone-beam CT and micro-CT in relation to nano-CT
    Amanda Pelegrin Candemil
    Jardel Francisco Mazzi-Chaves
    Matheus Lima Oliveira
    Guilherme Bovi Ambrosano
    Karla Farias Vasconcelos
    Ruben Pauwels
    Reinhilde Jacobs
    Manoel Damião Sousa-Neto
    [J]. Clinical Oral Investigations, 2023, 27 : 6413 - 6420
  • [6] A Micro-CT Analysis of Initial and Long-Term Pores Volume and Porosity of Bioactive Endodontic Sealers
    Radwanski, Mateusz
    Leski, Michal
    Puszkarz, Adam K.
    Sokolowski, Jerzy
    Hardan, Louis
    Bourgi, Rim
    Sauro, Salvatore
    Lukomska-Szymanska, Monika
    [J]. BIOMEDICINES, 2022, 10 (10)
  • [7] Application of nano-CT and high-resolution micro-CT to study bone quality and ultrastructure, scaffold biomaterials and vascular networks
    Salmon, Phil L.
    Sasov, Alexander Y.
    [J]. ADVANCED BIOIMAGING TECHNOLOGIES IN ASSESSMENT OF THE QUALITY OF BONE AND SCAFFOLD MATERIALS: TECHNIQUES AND APPLICATIONS, 2007, : 323 - +
  • [8] Micro-CT assessment of two different endodontic preparation systems
    Moura-Netto, Cacio
    Palo, Renato Miotto
    Ribeiro Camargo, Carlos Henrique
    Pameijer, Cornelis Hans
    Ramalho da Silva Bardauil, Marcia Regina
    [J]. BRAZILIAN ORAL RESEARCH, 2013, 27 (01) : 26 - 30
  • [9] Root canal filling quality of mandibular molars with EndoSequence BC and AH Plus sealers: A micro-CT study
    Roizenblit, Rafael Nigri
    Soares, Fabiola Ormiga
    Lopes, Ricardo Tadeu
    dos Santos, Bernardo Camargo
    Gusman, Heloisa
    [J]. AUSTRALIAN ENDODONTIC JOURNAL, 2020, 46 (01) : 82 - 87
  • [10] Dissolution, dislocation and dimensional changes of endodontic sealers after a solubility challenge: a micro-CT approach
    Silva, E. J.
    Perez, R.
    Valentim, R. M.
    Belladonna, F. G.
    De-Deus, G. A.
    Lima, I. C.
    Neves, A. A.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2017, 50 (04) : 407 - 414