Effect of Radiant Exposure on the Physical and Mechanical Properties of 10 Flowable and High-viscosity Bulk-fill Resin Composites

被引:1
|
作者
de Deus, R. a [1 ]
Oliveira, L. r s [1 ]
Braga, S. s l [1 ]
Price, M. T. H. Ribeiro R. B. [1 ,2 ]
Nunez, A. [3 ]
Loguercio, A. d [4 ]
Soares, C. j [1 ,5 ]
机构
[1] Univ Fed Uberlandia, Sch Dent, Dept Operat Dent & Dent Mat, Uberlandia, MG, Brazil
[2] Dalhousie Univ, Dept Dent Clin Sci, Halifax, NS, Canada
[3] Univ Estadual Ponta Grossa, Ponta Grossa, PR, Brazil
[4] Univ Estadual Ponta Grossa, Sch Dent, Ponta Grossa, PR, Brazil
[5] 1720 Ave, Campus Umuarama, Block 2B, Room 2B24, BR-38400902 Uberlandia, MG, Brazil
关键词
IN-VITRO; SHRINKAGE STRESS; POLYMERIZATION SHRINKAGE; RESTORATIVE MATERIALS; MARGINAL ADAPTATION; CUSPAL DEFLECTION; CURING LIGHT; RADIOPACITY; MICROHARDNESS; RADIODENSITY;
D O I
10.2341/23-025-L
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To evaluate the effect of the different radiant exposures from a multipeak light curing unit on the physical and mechanical properties of flowable and high-viscosity bulk-fill resin-based composites (RBC). Methods: Five flowable bulk-fill RBCs (Tetric N-Flow Bulk-fill, Ivoclar Vivadent; Filtek Bulk Fill Flow, 3M Oral Care; Opus Bulk Fill Flow APS, FGM; Admira Fusion x-base, Voco and; and SDR Plus Bulk Fill Flowable, Dentsply Sirona) and five high-viscosity bulk-fill RBCs (Tetric N-Ceram Bulkfill, Ivoclar Vivadent; Filtek One Bulk Fill, 3M Oral Care; Opus Bulk Fill APS, FGM; Admira Fusion x-tra, Voco; and SonicFill 2, Kerr) were photocured using a VALO Cordless light (Ultradent) for 10, 20, and 40 seconds at an irradiance of 1200, 800, or 400 mW/cm(2), resulting in the delivery of 4, 8, 12, 16, 24, 32, or 48 J/cm(2). Post -gel shrinkage (Shr) was calculated using strain -gauge test. The degree of conversion (DC, %) was calculated using FTIR. Knoop hardness (KH, N/mm(2)) and elastic modulus (E, MPa) were measured at the top and bottom surfaces. Logarithmic regressions between the radiant exposures and mechanical properties were calculated. Radiodensity was calculated using digital radiographs. Data of Shr and radiodensity were analyzed using two-way analysis of variance (ANOVA), and the DC, KH, and E data were analyzed with two-way ANOVA using split -plot repeated measurement tests followed by the Tukey test (a=0.05). Results: Delivering higher radiant exposures produced higher Shr values (p<0.001) and higher DC values (R-2=0.808-0.922; R-2=0.648-0.914, p<0.001), KH (R-2=0.707-0.952; R-2=0.738-0.919; p<0.001), and E (R-2=0.501-0.925; R-2=0.823-0.919; p<0.001) values for the flowable and high -viscosity RBCs respectively. Lower KH, E and Shr were observed for the flowable bulk -fill RBCs. All bulkfill RBCs had a radiopacity level greater than the 4 -mm thick aluminum step wedge. The radiant exposure did not affect the radiopacity. Conclusion: The Shr, DC, KH, and E values were highly correlated to the radiant exposure delivered to the RBCs. The combination of the higher irradiance for longer exposure time that resulted in radiant exposure between 24 J/cm(2) to 48 J/cm(2) produced better results than delivering 400 mW/ cm(2) for 40 s (16 J/cm(2)), and 800 mW/cm(2) for 20 seconds (16 J/cm(2)) or 1200 mW/cm(2) for 10 seconds (12 J/cm(2)). All the bulk -fill RBCs were sufficiently radiopaque compared to 4 mm of aluminum.
引用
收藏
页码:136 / 156
页数:21
相关论文
共 50 条
  • [1] Physical and Mechanical Properties of Bulk-Fill, Conventional, and Flowable Resin Composites Stored Dry and Wet
    Jafarpour, Dana
    Ferooz, Reihaneh
    Ferooz, Maryam
    Bagheri, Rafat
    [J]. INTERNATIONAL JOURNAL OF DENTISTRY, 2022, 2022
  • [2] Sufficiency of curing in high-viscosity bulk-fill resin composites with enhanced opacity
    Ilie, Nicoleta
    [J]. CLINICAL ORAL INVESTIGATIONS, 2019, 23 (02) : 747 - 755
  • [3] Sufficiency of curing in high-viscosity bulk-fill resin composites with enhanced opacity
    Nicoleta Ilie
    [J]. Clinical Oral Investigations, 2019, 23 : 747 - 755
  • [4] Curing behaviour of high-viscosity bulk-fill composites
    Ilie, Nicoleta
    Stark, Katharina
    [J]. JOURNAL OF DENTISTRY, 2014, 42 (08) : 977 - 985
  • [5] Handling and Mechanical Properties of Low-viscosity Bulk-fill Resin Composites
    Hirokane, E.
    Takamizawa, T.
    Tamura, T.
    Shibasaki, S.
    Tsujimoto, A.
    Barkmeier, W. W.
    Latta, M. A.
    Miyazaki, M.
    [J]. OPERATIVE DENTISTRY, 2021, 46 (05) : E185 - E198
  • [6] Polymerization Behavior and Mechanical Properties of High-Viscosity Bulk Fill and Low Shrinkage Resin Composites
    Shibasaki, S.
    Takamizawa, T.
    Nojiri, K.
    Imai, A.
    Tsujimoto, A.
    Endo, H.
    Suzuki, S.
    Suda, S.
    Barkmeier, W. W.
    Latta, M. A.
    Miyazaki, M.
    [J]. OPERATIVE DENTISTRY, 2017, 42 (06) : E177 - E187
  • [7] Effects of cigarette smoke on color, roughness and gloss of high-viscosity bulk-fill resin composites
    Theobaldo, Jessica Dias
    Vieira Junior, Waldemir Francisco
    Cortellazzi, Karine Laura
    Marchi, Giselle Maria
    Nunes Leite Lima, Debora Alves
    Aguiar, Flavio H. B.
    [J]. AMERICAN JOURNAL OF DENTISTRY, 2020, 33 (02): : 83 - 88
  • [8] The Effect of Gravity on Marginal Integrity of Different Flowable Bulk-Fill Resin Composites
    Baltacioglu, Ismail Hakki
    Demirel, Gulbike
    Kolsuz, Mehmet Eray
    Orhan, Kaan
    [J]. MEDICINA-LITHUANIA, 2024, 60 (03):
  • [9] Influence of irradiation time on subsurface degree of conversion and microhardness of high-viscosity bulk-fill resin composites
    Z. Tarle
    T. Attin
    D. Marovic
    L. Andermatt
    M. Ristic
    T. T. Tauböck
    [J]. Clinical Oral Investigations, 2015, 19 : 831 - 840
  • [10] Influence of irradiation time on subsurface degree of conversion and microhardness of high-viscosity bulk-fill resin composites
    Tarle, Z.
    Attin, T.
    Marovic, D.
    Andermatt, L.
    Ristic, M.
    Tauboeck, T. T.
    [J]. CLINICAL ORAL INVESTIGATIONS, 2015, 19 (04) : 831 - 840