Effect of Radiant Exposure on the Physical and Mechanical Properties of 10 Flowable and High-viscosity Bulk-fill Resin Composites

被引:1
|
作者
de Deus, R. a [1 ]
Oliveira, L. r s [1 ]
Braga, S. s l [1 ]
Price, M. T. H. Ribeiro R. B. [1 ,2 ]
Nunez, A. [3 ]
Loguercio, A. d [4 ]
Soares, C. j [1 ,5 ]
机构
[1] Univ Fed Uberlandia, Sch Dent, Dept Operat Dent & Dent Mat, Uberlandia, MG, Brazil
[2] Dalhousie Univ, Dept Dent Clin Sci, Halifax, NS, Canada
[3] Univ Estadual Ponta Grossa, Ponta Grossa, PR, Brazil
[4] Univ Estadual Ponta Grossa, Sch Dent, Ponta Grossa, PR, Brazil
[5] 1720 Ave, Campus Umuarama, Block 2B, Room 2B24, BR-38400902 Uberlandia, MG, Brazil
关键词
IN-VITRO; SHRINKAGE STRESS; POLYMERIZATION SHRINKAGE; RESTORATIVE MATERIALS; MARGINAL ADAPTATION; CUSPAL DEFLECTION; CURING LIGHT; RADIOPACITY; MICROHARDNESS; RADIODENSITY;
D O I
10.2341/23-025-L
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To evaluate the effect of the different radiant exposures from a multipeak light curing unit on the physical and mechanical properties of flowable and high-viscosity bulk-fill resin-based composites (RBC). Methods: Five flowable bulk-fill RBCs (Tetric N-Flow Bulk-fill, Ivoclar Vivadent; Filtek Bulk Fill Flow, 3M Oral Care; Opus Bulk Fill Flow APS, FGM; Admira Fusion x-base, Voco and; and SDR Plus Bulk Fill Flowable, Dentsply Sirona) and five high-viscosity bulk-fill RBCs (Tetric N-Ceram Bulkfill, Ivoclar Vivadent; Filtek One Bulk Fill, 3M Oral Care; Opus Bulk Fill APS, FGM; Admira Fusion x-tra, Voco; and SonicFill 2, Kerr) were photocured using a VALO Cordless light (Ultradent) for 10, 20, and 40 seconds at an irradiance of 1200, 800, or 400 mW/cm(2), resulting in the delivery of 4, 8, 12, 16, 24, 32, or 48 J/cm(2). Post -gel shrinkage (Shr) was calculated using strain -gauge test. The degree of conversion (DC, %) was calculated using FTIR. Knoop hardness (KH, N/mm(2)) and elastic modulus (E, MPa) were measured at the top and bottom surfaces. Logarithmic regressions between the radiant exposures and mechanical properties were calculated. Radiodensity was calculated using digital radiographs. Data of Shr and radiodensity were analyzed using two-way analysis of variance (ANOVA), and the DC, KH, and E data were analyzed with two-way ANOVA using split -plot repeated measurement tests followed by the Tukey test (a=0.05). Results: Delivering higher radiant exposures produced higher Shr values (p<0.001) and higher DC values (R-2=0.808-0.922; R-2=0.648-0.914, p<0.001), KH (R-2=0.707-0.952; R-2=0.738-0.919; p<0.001), and E (R-2=0.501-0.925; R-2=0.823-0.919; p<0.001) values for the flowable and high -viscosity RBCs respectively. Lower KH, E and Shr were observed for the flowable bulk -fill RBCs. All bulkfill RBCs had a radiopacity level greater than the 4 -mm thick aluminum step wedge. The radiant exposure did not affect the radiopacity. Conclusion: The Shr, DC, KH, and E values were highly correlated to the radiant exposure delivered to the RBCs. The combination of the higher irradiance for longer exposure time that resulted in radiant exposure between 24 J/cm(2) to 48 J/cm(2) produced better results than delivering 400 mW/ cm(2) for 40 s (16 J/cm(2)), and 800 mW/cm(2) for 20 seconds (16 J/cm(2)) or 1200 mW/cm(2) for 10 seconds (12 J/cm(2)). All the bulk -fill RBCs were sufficiently radiopaque compared to 4 mm of aluminum.
引用
收藏
页码:136 / 156
页数:21
相关论文
共 50 条
  • [41] Physical and mechanical characteristics of short fiber-reinforced resin composite in comparison with bulk-fill composites
    Jafarnia, Shiva
    Valanezhad, Alireza
    Shahabi, Sima
    Abe, Shigeaki
    Watanabe, Ikuya
    [J]. JOURNAL OF ORAL SCIENCE, 2021, 63 (02) : 148 - 151
  • [42] Clinical and radiographic evaluation of high viscosity bulk-fill resin composite restorations
    Alves Berti, Luiza Salles
    Turssi, Cecilia Pedroso
    Botelho do Amaral, Flavia Lucisano
    Basting, Roberta Tarkany
    Cintra Junqueira, Jose Luiz
    Panzarella, Francine Kuhl
    Reis, Andre Figueiredo
    Gomes Franca, Fabiana Mantovani
    [J]. AMERICAN JOURNAL OF DENTISTRY, 2020, 33 (04): : 213 - 217
  • [43] Bulk-fill Resin-based Composites: An In Vitro Assessment of Their Mechanical Performance
    Ilie, N.
    Bucuta, S.
    Draenert, M.
    [J]. OPERATIVE DENTISTRY, 2013, 38 (06) : 618 - 625
  • [44] Internal and marginal adaptation of high-viscosity bulk-fill composites in class II cavities placed with different adhesive strategies
    Haak, Rainer
    Naeke, Thomas
    Park, Kyung-Jin
    Ziebolz, Dirk
    Krause, Felix
    Schneider, Hartmut
    [J]. ODONTOLOGY, 2019, 107 (03) : 374 - 382
  • [45] Depth of cure of high-viscosity bulk-fill and conventional resin composites using varying irradiance exposures with a light-emitting diode curing unit
    Hasslen, Jennifer A.
    Barkmeier, Wayne W.
    Shaddy, Raymond S.
    Little, Jared R.
    [J]. JOURNAL OF ORAL SCIENCE, 2019, 61 (03) : 425 - 430
  • [46] Influence of various irradiation processes on the mechanical properties and polymerisation kinetics of bulk-fill resin based composites
    Ilie, Nicoleta
    Kessler, Andreas
    Durner, Juergen
    [J]. JOURNAL OF DENTISTRY, 2013, 41 (08) : 695 - 702
  • [47] The effect of bulk-fill flowable composites on the fracture resistance and cuspal deflection of endodontically treated premolars
    Toz, Tugba
    Tuncer, Safa
    Bozkurt, Funda Ozturk
    Tuncer, Aysun Kara
    Bag, Harika Gozukara
    [J]. JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2015, 29 (15) : 1581 - 1592
  • [48] Marginal integrity and physicomechanical properties of a thermoviscous and regular bulk-fill resin composites
    Soares, Barbara Monteiro
    Barbosa, Marianna Pires
    de Almeida, Rayane Velloso
    Jardim, Renata Nunes
    da Silva, Eduardo Moreira
    [J]. CLINICAL ORAL INVESTIGATIONS, 2024, 28 (09)
  • [49] Clinical comparison of high-viscosity glass-hybrid systems with a sculptable bulk-fill composite resin in different cavity types
    Atmaca, Yakup
    Karadas, Muhammet
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2024, 36 (08) : 1138 - 1152
  • [50] Mechanical and Biomimetic Characteristics of Bulk-Fill Resin Dental Composites Following Exposure in a Simulated Acidic Oral Environment
    Dahri, Waheed Murad
    Kumar, Naresh
    Altaf, Noorulain
    Mughal, Waqas
    Zafar, Muhammad Sohail
    [J]. BIOMIMETICS, 2023, 8 (01)